This research proposes a method to enhance the accuracy of resistance measurements for Resistive Sensors (Rx) using voltage divider and Anderson current loop circuits connected to the Analog-to-Digital Converter (ADC) of a microcontroller. Traditional circuits use a fixed reference resistor (Rref), which causes significant errors when the sensor's voltage drop differs greatly from the reference resistor. To address this, an Adaptive Reference Resistor (ADRR) using a Digital Potentiometer (DPOT) is introduced. The voltage drop across the resistive sensor is used to determine the control code for the DPOT. This adjusts the reference resistance to be close to sensor resistance. Moreover, the introduction of the Tuning Factor (k) for calibrating the measurement system significantly reduces errors. The experiment utilized a MCP41010 DPOT with 256 steps, whose resistance was measured and calibrated by a factor, k. Known resistances were used for accuracy testing within the range of 100 - 9,960 Ω. According to the results, setting the reference resistance interval to 100 Ω led to an error of less than 0.45% for the voltage divider circuit across the measurement range. Meanwhile, the series circuit based on the Anderson current loop demonstrated an error of less than 0.35%.
1 October 2025 in Bulletin of Electrical Engineering and Informatics
Air pollution has become a global issue due to rapid urbanization and industrialization. Air quality monitoring is essential for mitigating the adverse effects of air pollution on public health and the environment. This study presents a solar-powered internet of thing (IoT)-based air quality monitoring system designed for autonomous operation in outdoor settings. The prototype integrates an ESP32 microcontroller with low-cost sensors for PM2.5, PM10, temperature, humidity, and heat index. Powered by a solar panel and battery, the system ensures off-grid functionality, while Wi-Fi transmission to the Blynk platform, enables real-time visualization, historical record storage, and instant user access through mobile dashboards. The system was calibrated against reference instruments and deployed for 14 consecutive days. Results confirmed stable data transmission and reliable performance that suitability for outdoor use without reliance on grid power under real-world conditions. Furthermore, correlation analysis showed a strong relationship between PM2.5 and PM10, and moderate associations with humidity. Regression analysis further identified humidity and heat index as the most significant predictors, while temperature exhibited only minor influence. These findings demonstrate the feasibility of a low-cost, portable, and energy-autonomous IoT monitoring system, providing accurate real-time insights to support evidence-based air quality management.
Guangdong is China’s largest provincial electricity consumer (912.1 TWh in 2024). Using a Low Emissions Analysis Platform (LEAP) model calibrated to the 2024 provincial yearbook, this paper compares a Business-as-Usual (BAU) reference with three decarbonization pathways over 2024–2060: Policy-Instrument-Coupled (PIC), Deep-Electrification-and-Hydrogen (DEH) and Digital-economy-with-CCUS (DCN). From 862 Mt CO2 in 2024, BAU peaks at 1143 Mt in 2040, whereas the pathways fall to 139, 99 and 35 Mt of direct emissions in 2060. After BECCS removals, only DCN approaches neutrality (21 Mt net, comparable to a conservative provincial land-sink estimate). Forty-three control scenarios show that end-use efficiency and fuel switching deliver 85–91% of the 2060 reduction relative to BAU and the capacity mix 8–10%. In 10,000 correlated Monte Carlo draws over the tested ranges, the ranking DCN < DEH < PIC never changes. In an hourly check (three ERA5 weather years, stylized load), the pathways serve every hour with at most 17 GW of four-hour storage (20–32 GW with plan-level offshore wind and nuclear), whereas the BAU capacity path falls short from 2040. By 2060, 38–57% of the pathways’ must-run output is surplus, and electricity-supply cost per MWh rises in the reverse order of emission depth.
This paper introduces an enhanced speed control strategy for permanent magnet synchronous motors (PMSMs) through the application of sliding mode control (SMC) optimized by the Chess Optimization Algorithm (COA). Additionally, the proposed method is compared with other validated algorithms, such as Harris Hawk Optimization (HHO) and the Whale Optimization Algorithm (WOA). The SMC parameters are optimized using Integral of Time-weighted Absolute Error (ITAE) and Integral of Time-weighted Square Error (ITSE) as objectives function, and the controllers are validated in MATLAB/Simulink analyzing transient response, speed variation, and load disturbance conditions. The results show that COA-tuned SMC provides better performance, with the lowest overshoot of 0.1929% for ITAE and 3.4800% for ITSE, the fastest settling times of 0.00307 s for ITSE, and the lowest MAE and RMSE in most evaluated scenarios, offering the most balanced overall performance among the optimization algorithms tested. Comparison to PI and PID controllers demonstrates that SMC provides enhanced accuracy, robustness, and disturbance rejection. COA-SMC provides an efficient and stable solution for PMSM applications that demand quick and accurate speed regulation.