Hydrogen energy is regarded as an ideal solution for addressing climate change issues and an indispensable part of future integrated energy systems. The most environmentally friendly hydrogen production method remains water electrolysis, where the electrolyzer constructs the physical interface between electrical energy and hydrogen energy. However, few articles have reviewed the electrolyzer from the perspective of power supply topology and control. This review is the first to discuss the positioning of the electrolyzer power supply in the future integrated energy system. The electrolyzer is reviewed from the perspective of the electrolysis method, the market, and the electrical interface modelling, reflecting the requirement of the electrolyzer for power supply. Various electrolyzer power supply topologies are studied and reviewed. Although the most widely used topology in the current hydrogen production industry is still single-stage AC/DC, the interleaved parallel LLC topology constructed by wideband gap power semiconductors and controlled by the zero-voltage switching algorithm has broad application prospects because of its advantages of high power density, high efficiency, fault tolerance, and low current ripple. Taking into account the development trend of the EL power supply, a hierarchical control framework is proposed as it can manage the operation performance of the power supply itself, the electrolyzer, the hydrogen energy domain, and the entire integrated energy system.
15 June 2020 in IEEE Transactions on Applied Superconductivity
Dynamic resistance is essential to evaluate the performance of high temperature superconducting (HTS) coated conductors (CC), especially when applied in synchronous electric machines, and HTS flux pumps. The analytical expression of dynamic resistance has been proposed and verified in many cases, and it appears that dynamic resistance, Rdyn, is in a linear correlation with transport current, It, and the amplitude of external AC magnetic field, Bext. However, some experimental data has shown that, the linearity of Rdyn(It) and Rdyn(Bext) curves only exists within a certain range. To quantitatively describe this interval, the lower demarcation current, Idl, the upper demarcation current, Idu, and the corner field, Bcor, have been defined in this paper, with explicit formulas. The proposed demarcation currents and corner field used to characterize the non-linearity of dynamic resistance have been validated by simulation and experimental measurements. This paper further adds upon the existing knowledge regarding the interaction of dynamic resistance with transport current and magnetic field, which is particularly significant for accurate loss controlling in HTS magnets, rotating machines, and flux pumps.
This article addresses the challenges of the reduced efficiency in phase-shifted full-bridge series resonant converters (PSFB-SRCs) used within micro-inverters (MIs), especially under light load and high input voltage conditions. To enhance performance, first-order and second-order time-domain equivalent models that accurately predict the output gain across a wide range of operating conditions are developed. A novel control strategy is proposed, featuring turn-on time as a feedback variable, with phase shift angle and dead time as feedforward variables, enabling precise computation of frequency, duty cycle, and phase shift time for digital controllers. This ensures optimal efficiency, stability, and dynamic response, regardless of the load conditions. Experimental results from the prototype confirmed zero-voltage switching under heavy loads and efficient frequency limiting under light loads, achieving a peak efficiency of 97.8% at a 25 V input. Notably, the light load efficiency remained above 90% even at a 50 V input. These contributions significantly advance PSFB-SRC technology, providing robust solutions for high-efficiency MI applications in photovoltaic systems.
This article introduces a high-efficiency, high-voltage-ratio bidirectional DC–DC converter based on the Dual-Active-Bridge (DAB) topology, specifically designed for applications involving low-voltage, high-capacity cells. Addressing the critical challenge of enhancing bidirectional power transfer efficiency under ultra-high step-up ratios, which is essential for integrating renewable energy sources and battery storage systems into modern power grids, an optimized control strategy is proposed. This strategy focuses on refining switching patterns and minimizing conduction losses to improve overall system efficiency. Theoretical analysis revealed significant enhancements in efficiency across various operating conditions. Simulation results further confirmed that the converter achieved exceptional performance in terms of efficiency at extremely high voltage conversion ratios, showcasing full-range Zero-Voltage Switching (ZVS) capabilities and reduced circulating reactive power. Specifically, the proposed method reduced circulating reactive power by up to 22.4% compared to conventional fixed-frequency control strategies, while achieving over 35% overload capability. These advancements reinforce the role of DAB as a key topology for next-generation high-performance power conversion systems, facilitating more efficient integration of renewable energy and energy storage solutions, and thereby contributing to the stability and sustainability of contemporary energy systems.
5 April 2023 in IEEE Transactions on Power Delivery
This paper presents a delta-configured, modular multilevel, STATCOM with integrated partially-rated energy storage (ES) and submodules (SM) based on the Multi-Busbar Sub-module (MBSM) topology. The soft-paralleling of SM capacitors using the nature of diodes leads to lower SM voltage deviation and lower circulating current to be used for SM balancing and improves the overall operation of the converter. Partially rated ES are distributedly integrated in SMs to provide ancillary service, e.g. frequency support, in addition to the classic reactive power provision. The study uses the analytical formulation of the MBSM to derive the control system and the optimal phase angle of the circulating current required for SM balancing. A comparison of different operating modes (MBSM vs emulated full-bridge SM) is presented and confirmed by simulation results. Analysis indicates that the MBSM improves the power efficiency (30.5% total losses reduction at the 1 pu reactive power set-point and 3.56% reduction at 1 pu active power set-point) compared with the conventional full-bridge SM, at the cost of doubling the number of semiconductor devices; but not the number of sub-modules.
In this paper, a class of optimal and robust controller is designed for a typical energy router (ER) within the scenario of an energy Internet (EI) from the control perspective. As the core element of the EI, the considered ER is assumed to have access with photovoltaic (PV) units, wind turbine generators (WTGs), micro-turbines (MTs), fuel cells (FCs), battery energy storage (BES) devices, super capacities (SCs), loads and other ERs. Two control objectives are considered as follows. 1) Since the access of large-scale renewable energy sources (RESs) would lead to excessive DC bus voltage deviation within the ER system, a desired controller shall regulate the voltage deviation effectively. 2) According to the operational principle of EI, when multiple ERs are interconnected, an autonomous power balance of each ER is expected to be achieved with priority. Then the optimal energy dispatch problem shall be considered. When both two problems are considered simultaneously, a mixed robust H 2 /H ∞ control problem is formulated and is solved analytically. Simulations show the usefulness and effectiveness of the proposed scheme.