Abdullah Abdulrahman Al Aishan

Dr. Abdullah Abdulrahman Al Aishan


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
ANAhsan Naveed
Ahsan Naveed
RFRida E Fatima
Rida E Fatima
ZDZia Mohy Ud Din
Zia Mohy Ud Din
AAAbdullah Abdulrahman Al Aishan
Abdullah Abdulrahman Al Aishan
HGHedi Ammar GUESMI
Hedi Ammar GUESMI
JGJahan Zeb Gul
Jahan Zeb Gul
Reproducible electrode placement remains a critical, unresolved challenge in wearable ECG systems, where manual electrode attachment introduces inter-session positional error that degrades signal morphology and compromises multi-lead representation. Although the 12-lead clinical ECG system is the gold standard, conventional setups are often bulky, wired, and dependent on operator expertise, limiting their use in prehospital or remote care. Recent advancements in wearable and wireless ECG systems have improved mobility and real-time monitoring, but they typically suffer from limited lead coverage, discomfort, and unstable connectivity. This paper introduces BioShield-12, an anatomically adaptive thermoplastic polyurethane (TPU) shield fabricated using fused deposition modeling (FDM) to improve multi-site electrode placement and 12-lead electrocardiogram (ECG) reconstruction from a single-shield design based on anthropometric data from ten healthy adults (five male, five female; sizing cohort). Mechanical characterization confirmed TPU’s suitability as a compliant wearable substrate, with toughness of 34.4 MJ/m3 and elastic modulus of 79.1 MPa. Feasibility validation against a research-grade reference (BIOPAC MP36) in twenty healthy subjects (n = 20; 10 male, 10 female; mean age 21 ± 4 years) demonstrated consistent signal fidelity (SNR: 17.5–22.5 dB; Pearson r: 0.93–0.98; power-line interference ratio (PLIR): 1.0–3.2 × 10−5) and confirmed feasibility of 12-lead reconstruction. This work provides proof-of-concept for an additive manufacturing-based conformal electrode interface that eliminates variability in placement without needing individual attachment.

Verified
Journal Article
Open access
PDF file
Mohamed Abdelkader AboamerMohamed Abdelkader Aboamer
Mohamed Abdelkader Aboamer
RARASHED ALMOUSA
RASHED ALMOUSA
AAAhmad Alassaf
Ahmad Alassaf
AAAbdullah Abdulrahman Al Aishan
Abdullah Abdulrahman Al Aishan
FAFahad Saleiman M Aleisa
Fahad Saleiman M Aleisa
GSGHAZWAN NAJDAT SAIJARI
GHAZWAN NAJDAT SAIJARI
Natural bio-based fillers may support more sustainable dental impression materials, but their mechanical effects require verification. This study evaluated the compressive behavior of a light-body dental impression material containing 50 wt.% date seed powder (DSP) and explored whether a computational feature-matching approach could complement conventional statistics. Three specimens per formulation were compression-tested according to ASTM D575. Displacement was evaluated at human bite-force reference levels of 220, 260, 300, and 350 N. Welch’s independent-samples t-test was complemented by exploratory feature matching using seven original-domain and seven FFT-derived features, generating 14 features and 91 two-feature combinations. DSP showed consistently lower mean displacement than the Control, with differences of 0.147, 0.165, 0.182, and 0.201 mm, respectively; none reached statistical significance (p = 0.340, 0.311, 0.283, and 0.264). The computational analysis was concordant with the statistical findings, with the lowest standardized mean matched distance of 0.114497 and relatively limited separation in several top-ranked feature representations. Within the tested specimens, the DSP formulation showed encouraging compressive behavior and represents a promising sustainable natural filler. The exploratory computational approach also appears promising as a complementary multidimensional tool, but not a replacement for conventional statistical analysis.

15 April 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MCMuhammad Omar Omar Cheema
Muhammad Omar Omar Cheema
AAAlina Akhlaq
Alina Akhlaq
ZDZia Mohy Ud Din
Zia Mohy Ud Din
AAAbdullah Abdulrahman Al Aishan
Abdullah Abdulrahman Al Aishan
HGHedi Ammar GUESMI
Hedi Ammar GUESMI
JGJahan Zeb Gul
Jahan Zeb Gul
Chronic pruritus in patients with dermatological conditions causes physical discomfort, skin breakdown, sleep disturbance, and overall decline in quality of life. Persistent scratching can lead to a condition known as lichenification, which further deteriorates the skin. Lichenified skin is more susceptible to infections, which further complicates the treatment and prolongs the recovery time. This highlights the importance of accurately detecting and quantifying scratching behavior for effective management and intervention. All the existing technologies to monitor scratching involve the use of external sensor modalities such as an accelerometer and a gyroscope, followed by camera monitoring. However, such scratch detection methods are limited in their reliability in monitoring scratching intensity. This study aims to acquire muscle activity to accurately detect, quantify, and provide feedback on self-induced scratching intensity. Through a meticulous understanding of the synergies of hand muscles, three out of seven forearm muscles were identified that generate consistent and distinctive signals during scratching motion. These signals were acquired, preprocessed, segmented, and analyzed using both time and frequency domain features. The extracted 45 features of 3-Channel EMG signals were first optimized using recursive feature elimination and validated by cross-validation accuracies of the recursive feature elimination technique, with the highest optimized accuracy of 0.8628 when EMG of a complete combination of muscles is used. This study shows the promising results in facilitating enhanced diagnosis and management of scratching intensities. The model can be deployed into an embedded device for generating alerts and providing advanced therapy.

8 July 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
MCMuhammad Omar Omar Cheema
Muhammad Omar Omar Cheema
AAAlina Akhlaq
Alina Akhlaq
ZDZia Mohy Ud Din
Zia Mohy Ud Din
AAAbdullah Abdulrahman Al Aishan
Abdullah Abdulrahman Al Aishan
HGHedi Ammar GUESMI
Hedi Ammar GUESMI
JGJahan Zeb Gul
Jahan Zeb Gul
Chronic pruritus in patients with dermatological conditions causes physical discomfort, skin breakdown, sleep disturbance, and overall decline in quality of life. Persistent scratching can lead to a condition known as lichenification, which further deteriorates the skin. Lichenified skin is more susceptible to infections, which further complicates the treatment and prolongs the recovery time. This highlights the importance of accurately detecting and quantifying scratching behavior for effective management and intervention. All the existing technologies to monitor scratching involve the use of external sensor modalities such as an accelerometer and a gyroscope, followed by camera monitoring. However, such scratch detection methods are limited in their reliability in monitoring scratching intensity. This study aims to acquire muscle activity to accurately detect, quantify, and provide feedback on self-induced scratching intensity. Through a meticulous understanding of the synergies of hand muscles, three out of seven forearm muscles were identified that generate consistent and distinctive signals during scratching motions. These signals were acquired, preprocessed, segmented, and analyzed using both time- and frequency-domain features. The extracted 45 features of 3-Channel EMG signals were first optimized using recursive feature elimination and validated by cross-validation accuracies of the recursive feature elimination technique, with the highest optimized accuracy of 0.8628 attained when EMG of a complete combination of muscles is used. This study shows promising results in facilitating enhanced diagnosis and management of scratching intensities. The model may support future wearable devices for generating alerts and providing advanced therapy.