Tomáš Slavíček

Mr. Tomáš Slavíček

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 April 2023 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
DGDr. Michael Norderhaug Getz
Dr. Michael Norderhaug Getz
MPMarco Povoli
Marco Povoli
OKOzhan Koybasi
Ozhan Koybasi
TSTomáš Slavíček
Tomáš Slavíček
EMEduard Monakhov
Eduard Monakhov
Al2O3 has emerged as the surface passivation material of choice for p-type silicon in photovoltaics and has also become a candidate for passivating Si-based radiation sensors. However, the surface passivation of Al2O3 has been shown to degrade when exposed to gamma-radiation, making it of interest to determine methods of depositing Al2O3 that minimize the radiation-induced degradation on the surface passivation. In this study, we investigate the long-term stability and gamma-radiation hardness of Al2O3 prepared using the TMA+H2O+O3 precursor combination and how the pretreatment, the deposition temperature, and the film thickness affect the density of interface states, Dit, and fixed oxide charge, Qfix, before and after gamma-irradiation. We find that the surface saturation current density, J0s, of silicon passivated by Al2O3 increases after annealing but stabilizes over time depending on the Al2O3 thickness. Samples with thicknesses of 60 nm stabilize over days. J0s stabilizes at lower values with increased Al2O3 thickness. After exposure to 1 Mrad gamma-radiation, the samples still exhibit low Dit and high Qfix, with the best performing sample having a Dit of 1.5 × 1010 eV−1 cm−2 and a Qfix of −3.1 × 1012 cm−2. The deposition temperature appears to indirectly affect radiation hardness, owing to its impact on the hydrogen concentration in the film and at the Si–SiOx–Al2O3 interface. Lifetime measurements after irradiation indicate that Al2O3 still passivates the surface effectively. The carrier lifetime and Qfix can largely be recovered by annealing samples in O2 at 435 °C.

22 August 2022 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
PDF file
TSTomáš Slavíček
Tomáš Slavíček
JBJan Broulím
Jan Broulím
PFPavel Fojtík
Pavel Fojtík
MPMatěj Prokop
Matěj Prokop
PRPeter Rubovič
Peter Rubovič
Disasters involving radioactive materials are one of the most dangerous accidents a living organism can be exposed to. Individuals and first responders are in risk during accidents or interventions, due to radioactive debris impact, due to the use of depleted uranium ammunition or a malevolent act against individuals. Moreover, radioactive contamination of wounds causes internal exposure in the body and standard decontamination procedures cannot be applied. In order to deal with such situations, we are developing a measurement system consisting of a robotic arm, an array of various detectors and a corresponding methodology, which allows quantifying timely the spatial distribution of contamination and the radiation dose for the adequate medical response. The aim of this publication is to the present current status of the development of the described apparatus.

1 February 2025 in Journal of Instrumentation
Verified
Journal Article
Closed access
PKPatrik Kučera
Patrik Kučera
OUO. Urban
O. Urban
OROndrej Ruzicka
Ondrej Ruzicka
MVM. Vítek
M. Vítek
PSP.M. Stašek
P.M. Stašek
TSTomáš Slavíček
Tomáš Slavíček
Multi-channel analysers (MCAs) play a crucial role in spectral measurements, especially in the context of Silicon Photomultipliers (SiPMs) used for gamma spectroscopy. Most commercial MCAs, while highly accurate, remain cost-prohibitive for broader applications. This paper presents the design and implementation of a cost-effective MCA utilizing off-the-shelf components while achieving spectroscopy of gamma particles with reasonable resolution. The MCA board is built around the STM32G4 family microcontroller (MCU), which provides embedded analog components, timers, and high-resolution ADCs. This system is designed to reduce external component requirements, thereby decreasing costs and increasing system reliability. Experimental results demonstrate that the MCA can perform accurate real-time gamma radiation measurements with SiPM detectors. The device offers flexible connectivity options (USB, Ethernet, WiFi). The low-cost, accessible nature of the MCA opens up opportunities for educational and research applications in radiation detection.

18 September 2026 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
AOA. Owens
A. Owens
NGN. Grundmanis
N. Grundmanis
JŽJan Žemlička
Jan Žemlička
ALA. Lupilov
A. Lupilov
TSTomáš Slavíček
Tomáš Slavíček
VGVladimir Gostilo
Vladimir Gostilo

19 August 2026 in Sensors
Verified
Journal Article
Open access
PDF file
RFRobert Filgas
Robert Filgas
DMDaniel Matthiä
Daniel Matthiä
HCHugo Nathan Cintas
Hugo Nathan Cintas
TSTomáš Slavíček
Tomáš Slavíček
JJJindrich Jelinek
Jindrich Jelinek
GSGiovanni Santin
Giovanni Santin
The current interest in lunar exploration led by the Artemis program is pushing scientists to search for lunar water deposits directly on the surface of the Moon, using small robotic rovers. The Institute of Experimental and Applied Physics, Czech Technical University, Prague (IEAP CTU), is developing a miniature Timepix3-based detector called Neutron HardPix, which is capable of mapping water deposits using non-invasive detection of neutrons created underground by cosmic rays and thermalized by hydrogen. This neutron spectrometer measures count rate variations in thermal, epithermal and fast neutrons attributed to hydrogen abundance in the lunar subsurface, while monitoring cosmic radiation as a natural source of neutrons. Neutron HardPix is based on the miniature (<0.1 U, 130 g) radiation monitor HardPix, and has significant space heritage.

16 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
RFRobert Filgas
Robert Filgas
DMDaniel Matthiä
Daniel Matthiä
HCHugo Nathan Cintas
Hugo Nathan Cintas
TSTomáš Slavíček
Tomáš Slavíček
JJJindrich Jelinek
Jindrich Jelinek
GSGiovanni Santin
Giovanni Santin
A current interest in lunar exploration led by Artemis program pushes scientists to search for lunar water deposits directly on the surface of the Moon with small robotic rovers. The Institute of Experimental and Applied Physics, Czech Technical University in Prague (IEAP CTU) is developing a miniature Timepix3-based detector Neutron HardPix capable of mapping the water deposits using non-invasive detection of neutrons created underground by cosmic rays and thermalized by hydrogen. This neutron spectrometer measures count rate variations of thermal, epithermal and fast neutrons attributed to the hydrogen abundance in lunar subsurface, while monitoring cosmic radiation as a natural source of neutrons. Neutron HardPix is based on the miniature (< 0.1 U, 130 g) radiation monitor HardPix with multiple space heritage.