Mohd Syukri Ali

Dr. Mohd Syukri Ali

UMPEDAC, Universiti Malaya, Kuala Lumpur, Malaysia
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 December 2022 in Electric Power Systems Research
Verified
Journal Article
Closed access
MAMohd Syukri Ali
Mohd Syukri Ali
ABAb Halim Abu Bakar
Ab Halim Abu Bakar
AOAzimah Omar
Azimah Omar
AJAmirul Syafiq Abdul Jaafar
Amirul Syafiq Abdul Jaafar
SMSiti Hajar Mohamed
Siti Hajar Mohamed

10 February 2022 in Current Opinion in Chemical Engineering
Verified
Journal Article
Closed access
ASAmirul Syafiq
Amirul Syafiq
VBVengadaesvaran Balakrishnan
Vengadaesvaran Balakrishnan
MAMohd Syukri Ali
Mohd Syukri Ali
SDSanjay J Dhoble
Sanjay J Dhoble
NRNasrudin Abd Rahim
Nasrudin Abd Rahim
ABAb Halim Abu Bakar
Ab Halim Abu Bakar

1 February 2014 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Closed access
ABA.H.A. Bakar
A.H.A. Bakar
MAMohd Syukri Ali
Mohd Syukri Ali
CTChiaKwang Tan
ChiaKwang Tan
Hazlie MokhlisHazlie Mokhlis
Hazlie Mokhlis
HAH. Arof
H. Arof
HIH.A. Illias
H.A. Illias

1 May 2021 in Energy Strategy Reviews
Verified
Journal Article
Open access
MAMuhammad Shakeel Ahmad
Muhammad Shakeel Ahmad
MAMohd Syukri Ali
Mohd Syukri Ali
NRNasrudin Abd Rahim
Nasrudin Abd Rahim

9 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
KAKalaiselvi Aramugam
Kalaiselvi Aramugam
HIHazlee Azil Illias
Hazlee Azil Illias
YCYern Chee Ching
Yern Chee Ching
MAMohd Syukri Ali
Mohd Syukri Ali
Mohamad Zul Hilmey MakmudMohamad Zul Hilmey Makmud
Mohamad Zul Hilmey Makmud
The installation of a corona ring on an insulator string on a transmission line is one of the solutions to reduce the electric field stress surrounding the energised end of the insulator string. However, installing a corona ring with an optimum design to reduce the electric field magnitude on an insulator string is a challenging task. Therefore, in this work, a method to achieve the optimum design of a corona ring for 132 kV composite non-ceramic insulator string was proposed using two optimisation methods: the Imperialist Competitive Algorithm (ICA) and Grey Wolf Optimisation (GWO). A composite non-ceramic insulator string geometry with and without a corona ring was modelled in finite element analysis and used to obtain the electric field distribution in the model geometry. The electric field distribution was evaluated using a variation in the corona ring’s dimensions, i.e., the ring diameter, the ring tube diameter and the vertical position of the ring along the insulator string. From the results achieved, a comparison of the minimum electric field magnitude along the insulator string with a corona ring design shows that the minimum electric field magnitude is found to be lower using optimisation techniques compared to without using optimisation techniques by between 3.724% and 3.827%. Hence, this indicates the capability and effectiveness of the proposed methods in achieving the optimum design of a corona ring on an insulator string.

26 April 2017 in Arabian Journal for Science and Engineering
Verified
Journal Article
Closed access
PDF file
MAMohd Syukri Ali
Mohd Syukri Ali
ABAb Halim Abu Bakar
Ab Halim Abu Bakar
CTChiaKwang Tan
ChiaKwang Tan
HAHamzah Arof
Hamzah Arof
Hazlie MokhlisHazlie Mokhlis
Hazlie Mokhlis
MTMohamad Sofian Abu Talip
Mohamad Sofian Abu Talip