Climate change and an increase in urbanization are severely testing urban drainage systems; at the same time, population growth is leading to an increase in demand for water resources, while climate change is more likely to reduce the amount of water that is available to meet this demand. The present study finds a solution to both problems by assuming a hybrid use of detention basins, i.e., providing a real-time control system (RTC) for the outfall discharge managed according to the rainfall forecast and the water level in the tank, to reuse rainwater for non-potable use and, at the same time, to guarantee the hydraulic protection of the downstream system. Twenty-seven scenarios were simulated using the numerical model SWMM 5.1, assuming different types of controls on the discharge. The simulations show a non-potable water-saving efficiency from a minimum of 32% to a maximum of 90%, and the reduction in volume discharged is between 11% and 31%, while the peak flow rate varies more significantly depending on the type of control used. These results highlight the detention basins’ potential deriving from the hybrid use of this system with rainwater harvesting systems.
The first flush (FF) phenomenon is commonly associated with a relevant load of pollutants, raising concerns about water quality and environmental management in agro-urban areas. An FF event can potentially transport contaminated water into a receiving water body by activating combined sewer overflow (CSO) systems present in the drainage urban network. Therefore, accurately characterizing FF events is crucial for the effective management of sewer systems and for limiting environmental degradation. Given the ongoing controversy in the literature regarding the delineation of FF event occurrences, there is an unavoidable necessity for further investigations, especially experimental-based ones. This study presents the outcomes of an almost two-year field campaign focused on assessing the water quantity and quality of two combined sewer systems in Northern Italy. For this purpose, various hydro-meteorological variables, including precipitation, flow rate, temperature, and solar radiation, in addition to water quality analytics, were measured continuously to capture stormwater events. Throughout the monitoring period, sixteen stormwater events were identified and analyzed using five indices usually adopted in the literature to identify FF occurrences. The results indicate that there is a strong positive correlation between the mass first flush ratios calculated for nutrients and three factors, including maximum rainfall intensity, maximum flow rate, and antecedent dry weather period. Furthermore, rainfall duration was found to possess a strong negative correlation with the mass first flush ratios calculated for nutrients. However, for the same rainfall event, the occurrence of FF has never been unanimously confirmed by the indices examined in this study. Moreover, different macro-groups of pollutants can behave differently. Thus, it becomes apparent that relying solely on a priori analyses, without the support of data from experimental monitoring campaigns, poses a risk when designing actions for the mitigation of FF occurrences.
A global shift towards renewable energy production, driven primarily by the challenges posed by climate change, is currently underway. In this context, the utilization of heat recovery from municipal wastewater emerges as a promising green technology. Notably, the advantage of implementing energy recovery in sewers, as opposed to wastewater treatment plants (WWTPs), lies in the higher temperature of the wastewater and its proximity to potential heat users. Despite these benefits, concerns arise regarding the potential adverse effects on biological wastewater treatment processes downstream of the heat recovery section, particularly during colder seasons. This paper seeks to assess the impact of a heat recovery system along the sewer network on the efficiency of biological wastewater treatment processes. The methodology involves a modeling analysis of a real sewage network in Italy. Under typical northern Italy climate conditions, the results demonstrate the feasibility of heat recovery in sewers for WWTPs designed with a sludge residence time under aerobic conditions (SRTaer) greater than 13 days. In such cases, the nitrification process remains relatively unaffected. However, for lower SRTaer values, a case-specific feasibility assessment is recommended to evaluate the overall process efficiency comprehensively.