Petr Zakopal

Mr. Petr Zakopal

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2024 in Energies
Verified
Journal Article
Open access
PDF file
JKJakub Kučera
Jakub Kučera
PZPetr Zakopal
Petr Zakopal
FBFilip Baum
Filip Baum
OLOndrej Lipcak
Ondrej Lipcak
The increasing popularity of electric drives employing an isolated dual-inverter (DI) topology is motivated by their superior DC-link voltage and power utilization, fault-tolerant operation, and potential for multilevel operation. These attributes are significant in battery-powered transportation, such as electric vehicles and aviation. Given the considerable freedom in modulation and control of the DI topology, this paper researches the impact of reference voltage vector distribution between the two individual inverters. The study also evaluates the influence of two well-established asynchronous modulation strategies—Space Vector PWM (SVPWM) and Depenbrock’s Discontinuous Modulation (DPWM1). Since simulation tools nowadays play a crucial role in power electronics design and concept verification, the results are based on extensive and detailed models in Matlab/Simulink. Employing the basic field-oriented control of a 12 kW induction motor with precisely parameterized SiC switching devices for accurate loss calculation, this research reveals the possibility of significant energy savings at multiple operating points. Notably, optimal efficiency is achieved when one inverter operates up to half of the nominal speed while the other solely establishes a neutral point for the winding. Moreover, the results highlight DPWM1 as a superior strategy for the DI topology, showcasing reduced converter losses. Overall, it is shown that the system’s losses can be significantly reduced just by the design of the voltage vector distribution in the drive’s operating range and the modulation strategy selection.

2 March 2026 in IEEE Access
Verified
Journal Article
Open access
PZPetr Zakopal
Petr Zakopal
OLOndrej Lipcak
Ondrej Lipcak
Jan BauerJan Bauer
Jan Bauer
Operation of electric drives in the overmodulation region and six-step can optimize switching losses and increase the utilization of the dc-link voltage, but inevitably introduces low-order voltage harmonics that appear as current distortions in the stator winding. These harmonics adversely affect the field-oriented control loops, which in theory operate on fundamental components only. This paper presents an analytical method for mitigating low-order current harmonics in a feedback path of overmodulated Synchronous Reluctance Machine (SynRM) drives controlled under a combined Maximum Torque Per Ampere (MTPA) and Field-Weakening (FW) strategy. The proposed algorithm analytically estimates the 5th, 7th, 11th, and 13th harmonic components using explicit equations and synthesizes compensating current vectors using a machine model with differential inductances that accurately capture magnetic saturation and cross-saturation. Simulation and experimental results obtained on an 11kW SynRM drive confirm a substantial reduction in the $d$ - and $q$ -axis current ripple in the feedback path without deteriorating dynamic performance. The proposed approach enables smooth operation up to the six-step mode and provides a robust foundation for future observer-based or sensorless control schemes that rely chiefly on fundamental current and voltage components.