Agata Rosińska

Prof. Agata Rosińska


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Journal of Environmental Management
Verified
Journal Article
Closed access
ARAgata Rosińska
Agata Rosińska

22 January 2024 in Energies
Verified
Journal Article
Open access
PDF file
ARAgata Rosińska
Agata Rosińska
KRKlaudia Rakocz
Klaudia Rakocz
Studies were carried out to assess changes in biodegradable dissolved organic carbon (BDOC) and assimilable organic carbon (AOC) in groundwater and surface waters after two processes: ozonation and ozonation/UV. The tested water was in contact with O3 firstly for 4 and secondly for 15 min. Three doses of disinfectant were used: 1.6 mg/L, 5.0 mg/L, and 10.0 mg/L. The UV radiation time was 10 and 30 min. The greatest change in AOC and BDOC for groundwater was observed at an O3 dose of 10.0 mg/L and a contact time of 15 min, by 400 and 197%, respectively. On the other hand, for surface water, it was shown that after the ozonation/UV process, the AOC and BDOC content decreased after both 10 and 30 min of radiation in comparison to the water after ozonation. The AOC content decreased by 33% and 22%, respectively, and the BDOC content by 27% and 31%, respectively. The results obtained in this study provide new information on the effect of different ozonation conditions and the combined method on the level of biodegradable organic fraction of water. It is recommended that BDOC and AOC should be monitored in Poland as routine indicators during the preparation of drinking water.

10 June 2024 in Materials
Verified
Journal Article
Open access
MWMałgorzata Wolska
Małgorzata Wolska
MKMalgorzata Kabsch-Korbutowicz
Malgorzata Kabsch-Korbutowicz
ARAgata Rosińska
Agata Rosińska
ASAnna Solipiwko-Pieścik
Anna Solipiwko-Pieścik
Halina Anna Urbańska-KozłowskaHalina Anna Urbańska-Kozłowska
Halina Anna Urbańska-Kozłowska
Tests of microfiltration efficiency used for the pretreatment of backwash water from sand filters were conducted at two water treatment plants treating surface water and infiltration water. Microfiltration efficiency was evaluated for three membrane modules: two with polymeric membranes and one with a ceramic membrane. This study showed that the contaminants that limit the reuse of backwash water from both plants by returning them to the water treatment line are mostly microorganisms, including pathogenic species (Clostridium perfringens). Additionally, in the case of backwash water from infiltration water treatment, iron and manganese compounds also had to be removed before its recirculation to the water treatment system. Unexpectedly, organic carbon concentrations in both types of backwash water were similar to those present in intake waters. Microfiltration provided for the removal of organic matter, ranging from 19.9% to 44.5% and from 7.2% to 53.9% for backwash water from the treatments of surface water and infiltration water, respectively. Furthermore, the efficiency of the iron removal from backwash water from infiltration water treatment was sufficient to ensure good intake water quality. On the other hand, manganese concentrations in the backwash water, from infiltration water treatment, pretreated using the microfiltration process exceeded the levels found in the intake water and were, therefore, an additional limiting factor for the reuse of the backwash water. In both types of backwash water, the number of microorganisms, including Clostridium perfringens (a pathogenic one), was a limiting parameter for backwash water reuse without pretreatment. The results of the present study showed the possibility for using microfiltration for the pretreatment of backwash water, regardless of its origin but not as the sole process. More complex technological systems are needed before recirculating backwash water into the water treatment system. The polyvinylidene fluoride (PVDF) membrane proved to be the most effective for DOC and microorganism removal from backwash water.