Halina Anna Urbańska-Kozłowska

Dr. Halina Anna Urbańska-Kozłowska


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2023 in Water
Verified
Journal Article
Open access
PDF file
MWMałgorzata Wolska
Małgorzata Wolska
Halina Anna Urbańska-KozłowskaHalina Anna Urbańska-Kozłowska
Halina Anna Urbańska-Kozłowska
Due to the worldwide water crisis and diminishing water supplies, it is imperative to reduce water use and reuse it. One possible source of water is the washings created during the purification of drinking water. Backwashing constitutes 2–8% of the treated water used globally; it is more commonly used, primarily for irrigation or to expand surface/groundwater resources. Therefore, recirculating it at the beginning of the water treatment system is reasonable and justifiable, as it can lead to a decrease in the cost of the water that is being used. A study of variations in the content of washings in two water treatment plants revealed the requirement for pollutants to be removed before the water is reused. For the safety of consumers, the presence of microbes in backwashings from both facilities was essential. Variability in the amount and composition of backwashings was higher for surface water treatment in comparison to infiltration water treatment; however, the amount of backwashings was greater in infiltration water. The quantity of microorganisms, including indicator ones, was substantially higher in washings following surface water treatment. On the other hand, in the washings from the infiltration water treatment, large amounts of iron and manganese compounds were present, the recycling of which would reduce the effectiveness of infiltration water treatment. Pre-treatment backwashings from both facilities will be suitable for the suspension separation procedures and disinfection. It is essential to compare the costs connected with water use against the anticipated cost of washing. The potential to purify additional water in the event of a worsening water shortage, however, is the most significant advantage of water reuse. Recycling of the washings will allow to reduce the fees for the use of the environment, even to EUR 150,000 and EUR 250,000 per year for surface and infiltration WTP, respectively.

10 June 2024 in Materials
Verified
Journal Article
Open access
MWMałgorzata Wolska
Małgorzata Wolska
MKMalgorzata Kabsch-Korbutowicz
Malgorzata Kabsch-Korbutowicz
ARAgata Rosińska
Agata Rosińska
ASAnna Solipiwko-Pieścik
Anna Solipiwko-Pieścik
Halina Anna Urbańska-KozłowskaHalina Anna Urbańska-Kozłowska
Halina Anna Urbańska-Kozłowska
Tests of microfiltration efficiency used for the pretreatment of backwash water from sand filters were conducted at two water treatment plants treating surface water and infiltration water. Microfiltration efficiency was evaluated for three membrane modules: two with polymeric membranes and one with a ceramic membrane. This study showed that the contaminants that limit the reuse of backwash water from both plants by returning them to the water treatment line are mostly microorganisms, including pathogenic species (Clostridium perfringens). Additionally, in the case of backwash water from infiltration water treatment, iron and manganese compounds also had to be removed before its recirculation to the water treatment system. Unexpectedly, organic carbon concentrations in both types of backwash water were similar to those present in intake waters. Microfiltration provided for the removal of organic matter, ranging from 19.9% to 44.5% and from 7.2% to 53.9% for backwash water from the treatments of surface water and infiltration water, respectively. Furthermore, the efficiency of the iron removal from backwash water from infiltration water treatment was sufficient to ensure good intake water quality. On the other hand, manganese concentrations in the backwash water, from infiltration water treatment, pretreated using the microfiltration process exceeded the levels found in the intake water and were, therefore, an additional limiting factor for the reuse of the backwash water. In both types of backwash water, the number of microorganisms, including Clostridium perfringens (a pathogenic one), was a limiting parameter for backwash water reuse without pretreatment. The results of the present study showed the possibility for using microfiltration for the pretreatment of backwash water, regardless of its origin but not as the sole process. More complex technological systems are needed before recirculating backwash water into the water treatment system. The polyvinylidene fluoride (PVDF) membrane proved to be the most effective for DOC and microorganism removal from backwash water.

4 May 2026 in Membranes
Verified
Journal Article
Open access
PDF file
MWMałgorzata Wolska
Małgorzata Wolska
MKMalgorzata Kabsch-Korbutowicz
Malgorzata Kabsch-Korbutowicz
Fausto A. CanalesFausto A. Canales
Fausto A. Canales
JCjavier Andrés Carpintero
javier Andrés Carpintero
Halina Anna Urbańska-KozłowskaHalina Anna Urbańska-Kozłowska
Halina Anna Urbańska-Kozłowska
This study assessed the performance of three microfiltration (MF) membrane modules: M1 (spiral, polyvinylidene fluoride), M2 (capillary, polypropylene), and M3 (capillary, α-Alumina) in treating backwash water from utility-scale surface water (SW) and infiltration water (IW) plants, each with a capacity of approximately 100,000 m3/day. Considering 168 h (one-week) filtration cycles, the membranes were evaluated for permeate flux, turbidity removal, dissolved organic carbon (DOC) removal, and reduction in total number of microorganisms (TNM). In contrast to most previous studies that have primarily examined surface water sources under laboratory conditions, this research contributes to the literature by evaluating membrane performance using actual backwash water from both SW and IW treatment plants. The comparative assessment of three structurally and materially distinct membrane modules under identical flow-through conditions yields new insights into the trade-offs among hydraulic performance, contaminant removal, and treatment cost. Logarithmic models fitted to permeate flux data yielded determination coefficients (R2) ranging from 0.60 to 0.99, supporting the prediction of early-stage performance. No consistent trend in flux decline was observed, mainly due to fluctuations in the water bacterial load. With a median TNM removal efficiency of 97%, M1 outperformed M2 and M3 (84% and 70%, respectively) in terms of microorganism removal. The effectiveness of DOC removal generally depended on the type of backwash water; the highest efficiency was observed for M2 in the case of backwash from IW treatment and for M1 in the case of backwash from SW treatment. M2 provided the highest permeate flux rates, regardless of water type or operational limitations. The ceramic membrane (M3) exhibited the greatest variability in hydraulic performance and removal efficiency, depending on the type of backwash water. A simplified cost analysis over two filtration cycles found that treatment costs were generally higher for SW backwash, with differences reaching up to 90% between membrane-water type combinations. Although treatment costs are higher than those for raw water treatment, the increasing water scarcity makes it a potential additional source of safe water.

10 June 2026 in Water
Verified
Journal Article
Open access
PDF file
ASAnna Solipiwko-Pieścik
Anna Solipiwko-Pieścik
MWMałgorzata Wolska
Małgorzata Wolska
MKMalgorzata Kabsch-Korbutowicz
Malgorzata Kabsch-Korbutowicz
Halina Anna Urbańska-KozłowskaHalina Anna Urbańska-Kozłowska
Halina Anna Urbańska-Kozłowska
This study investigates the influence of organic matter properties in surface waters on the efficiency of single- and two-stage coagulation processes in drinking water treatment plants. The research was conducted at three treatment plants supplied by different surface water sources over a 15-month monitoring period. The analyzed parameters included total and dissolved organic carbon (TOC and DOC), biodegradable dissolved organic carbon (BDOC), water color, UV absorbance, zeta potential, and molecular weight distribution of organic substances. The results showed that coagulation efficiency depends strongly on both the concentration and the molecular characteristics of organic matter. The highest removal efficiency was observed for high-molecular-weight fractions (>2.0 kDa), mainly humic substances, whereas low-molecular-weight compounds were removed less effectively. The study also demonstrated that surrogate spectrophotometric parameters, particularly UV254 absorbance and color at 410 nm, can be used to monitor and optimize the coagulation process. Given the increasing frequency of extreme climate events and rapid shifts in raw water quality, optimizing single- and two-stage coagulation configurations has become an urgent operational necessity. This work provides a novel direct linkage between simple spectrophotometric indexes and precise chromatographic molecular ranges, delivering an immediate, high-impact predictive tool for real-time dosage optimization in water treatment engineering.