Mitigating heat generation in electric vehicle (EV) batteries is crucial for safety, operational efficiency, and battery lifespan. Liquid-cooled cold plates are widely used; however, comparative studies of channel geometries are often hindered by inconsistent experimental conditions. This study systematically compares six cold plate configurations under identical cross-sectional areas and uniform thermal boundary conditions. These controls isolate the effect of geometry on performance. Computational fluid dynamics (CFDs) was used to evaluate six configurations, derived from three main channel layouts (serpentine with eight U-turns, serpentine with six U-turns, and elliptical) and two cross-sectional shapes (circular and square). The serpentine square-tube design with eight U-turns exhibited the lowest thermal resistance (0.0159 K/W). The circular-tube variant achieved the most uniform temperature distribution (TUI > 0.53). The six U-turn circular-tube configuration demonstrated the lowest pressure drop (11.7 kPa). The results indicate that no single design optimizes all performance metrics, highlighting trade-offs between cooling effectiveness, temperature uniformity, and hydraulic efficiency. By isolating geometric variables, this study offers targeted design recommendations for engineers developing battery thermal management systems (BTMS).
Excessive heat will reduce the torque, power, and efficiency of the in-wheel motor, for example, the in-wheel motor used for an electric scooter. This study discusses an effort to reduce the temperature of the in-wheel motor of an electric scooter by making grooves on the cover surface. If the temperature of the in-wheel motor cover is low, it will reduce the temperature of the in-wheel motor as a whole. This research uses the finite element method: steady-state thermal analysis and transient thermal analysis. The software used is Ansys Workbench. Suppose a heat flux of 1000 W/m 2 is inside the in- wheel motor, the metal used as a cover is aluminum, 22°C is the starting temperature, and the ambient temperature is 28°C. The results showed that the grooves on the in-wheel motor cover caused the temperature to be reduced by 8.4%, and the total heat flux increased by 8.3% compared to the standard in-wheel motor cover (cover without modifications). In this study, the transient thermal analysis described the heat transfer process better than a steady-state thermal analysis.
This research proposes a novel cooling system to minimize the external rotor type of electric motor temperature by installing fan blades (wafters) on the inner housing of the electric motor. Fan blades (wafters) are made by printing using 3D printer technology and using polylactic acid (PLA) as the material. Wafters are then installed on an in-wheel motor with a power of 1500 W, having 48 poles and 52 slots. The study included thermal simulation and experimental techniques to ascertain how fan blades (wafters) affected the electric motor’s thermal properties. The motor rotated at 500 rpm during the experimental test with no load condition. The temperature of the electric motor is known using an infrared thermal imager. Using Ansys Motor-CAD 15.1 software, thermal modeling employs the lumped circuit model approach. Thermal simulation results show almost the same results as the experimental test results. Applying wafters on the in-wheel motor housing significantly reduces the winding temperature by 3.047 °C or experiences a temperature reduction of 4.34%. Using wafters in the in-wheel motor housing also speeds up the stable state temperature of the electric motor by 9 min compared to in-wheel motors without wafters.
The automotive technology race to improve the efficiency of engine performance is increasing, one of which is the use of heat energy in car radiators. This is in addition to reducing the workload of the engine. It can also produce electrical energy. This experiment uses four pieces of TEC1-12706 thermoelectric generators (TEG) which are arranged in series with heat sink construction in the direction of the fluid flow mounted directly above the TEG fixture. TEG Fixture will be installed on Lombardini diesel engine upper hose radiator LDW1404. This experiment produces a maximum voltage of 2.05 volts, with the current strength of 68.4 mA (0.064 A) and the power generated is 140.22 mA (0.14 A) with a difference in heat sink temperature from the heat side of 17, 8°C.
The increasing public demand for electric vehicles also impacts the demand for electric motors. The prominent problem electric motors faces are excess heat when operating because it affects the age and performance of the electric motor. Installing fins on the electric motor housing is one way to reduce heat on the electric motor. In this study, a comparison of the six-fin design was carried out, and the effect on the thermal characteristics of the electric motor was examined. Fins are mounted radially and axially. The six types of fin designs studied are radial fins-round, radial fins-square, radial fins-servo, axial fins-round, axial fins-square, and axial fins-servo. The research uses the lumped circuit models method, and the software used is Motor-CAD. The type of electric motor being studied is a brushless permanent magnet machine (BPM) with an internal rotor. The study's findings indicate that the fin's performance in cooling the electric motor depends on its area. The lower temperatures in the axial fins-servo and radial fins-square compared to other fin designs are due to the broader area of the axial fins-servo and radial fins-square compared to the others. Axially mounted fins provide better cooling than radially mounted fins. For example, the winding temperature on the axial fins-servo is 140.54°C, and the winding temperature on the radial fins-square is 140.86°C even though the area of the axial fins-servo is 22.7% smaller than the area of the radial fins-servo.