Susana Novais

Dr. Susana Novais


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Journal of Power Sources
Verified
Journal Article
Closed access
MNMicael Nascimento
Micael Nascimento
SNSusana Novais
Susana Novais
MDMarkus S. Ding
Markus S. Ding
MFMarta Ferreira
Marta Ferreira
SKStephan Koch
Stephan Koch
JPJoão L. Pinto
João L. Pinto

9 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
PRPaulo Roriz
Paulo Roriz
SSSusana Silva
Susana Silva
Orlando FrazãoOrlando Frazão
Orlando Frazão
SNSusana Novais
Susana Novais
The use of sensors in the real world is on the rise, providing information on medical diagnostics for healthcare and improving quality of life. Optical fiber sensors, as a result of their unique properties (small dimensions, capability of multiplexing, chemical inertness, and immunity to electromagnetic fields) have found wide applications, ranging from structural health monitoring to biomedical and point-of-care instrumentation. Furthermore, these sensors usually have good linearity, rapid response for real-time monitoring, and high sensitivity to external perturbations. Optical fiber sensors, thus, present several features that make them extremely attractive for a wide variety of applications, especially biomedical applications. This paper reviews achievements in the area of temperature optical fiber sensors, different configurations of the sensors reported over the last five years, and application of this technology in biomedical applications.

30 August 2016 in Sensors
Verified
Journal Article
Open access
PDF file
SNSusana Novais
Susana Novais
MNMicael Nascimento
Micael Nascimento
LGLorenzo Grande
Lorenzo Grande
Maria de Fátima DominguesMaria de Fátima Domingues
Maria de Fátima Domingues
Paulo AntunesPaulo Antunes
Paulo Antunes
João De Lemos PintoJoão De Lemos Pinto
João De Lemos Pinto
The integration of fiber Bragg grating (FBG) sensors in lithium-ion cells for in-situ and in-operando temperature monitoring is presented herein. The measuring of internal and external temperature variations was performed through four FBG sensors during galvanostatic cycling at C-rates ranging from 1C to 8C. The FBG sensors were placed both outside and inside the cell, located in the center of the electrochemically active area and at the tab-electrode connection. The internal sensors recorded temperature variations of 4.0 ± 0.1 °C at 5C and 4.7 ± 0.1 °C at 8C at the center of the active area, and 3.9 ± 0.1 °C at 5C and 4.0 ± 0.1 °C at 8C at the tab-electrode connection, respectively. This study is intended to contribute to detection of a temperature gradient in real time inside a cell, which can determine possible damage in the battery performance when it operates under normal and abnormal operating conditions, as well as to demonstrate the technical feasibility of the integration of in-operando microsensors inside Li-ion cells.

24 September 2018 in IEEE Photonics Journal
Verified
Journal Article
Open access
SNSusana Novais
Susana Novais
CFCatarina I. A. Ferreira
Catarina I. A. Ferreira
MFMarta Ferreira
Marta Ferreira
João De Lemos PintoJoão De Lemos Pinto
João De Lemos Pinto
A reflective fiber optic sensor based on multimode interference for the measurement of refractive index variations in glucose aqueous solutions is proposed. The sensor is fabricated by splicing a short section of coreless silica fiber to standard single mode fiber. The influence of the coreless fiber dimensions on the sensor performance is analyzed. By changing the sensor length, no significant impact is observed. However, the reduction of the sensing head diameter leads to a large improvement of the sensitivity. The smaller sensor, with a length of 5 mm and a diameter of 24 μm, presents a maximum sensitivity of 1467.59 nm/RIU, for the refractive index range between 1.364 and 1.397 RIU. Taking into account the acquisition system, a maximum theoretical resolution of 6.8 × 10 -5 RIU is achieved.

1 November 2018 in Optical Fiber Technology
Verified
Journal Article
Closed access
SNSusana Novais
Susana Novais
MFMarta S. Ferreira
Marta S. Ferreira
JPJoão L. Pinto
João L. Pinto

18 December 2017 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
SNSusana Novais
Susana Novais
MFMarta Ferreira
Marta Ferreira
João De Lemos PintoJoão De Lemos Pinto
João De Lemos Pinto
A fiber sensor based on a Fabry-Perot cavity is reported for measuring mixtures of water and glycerin. The sensor is fabricated by producing an air bubble near the end face of a multimode fiber section, and reshaping the tip in order to produce a thin silica diaphragm. It is observed that there is dependence between diaphragm dimensions and the structure sensitivity. The sensor with a 20 μm thick diaphragm presents a sensitivity of 7.81pm/wt.% regarding the variation of water mass fraction in glycerin. With this sensing head, an experimental resolution of 2.5 wt.% is estimated. By converting the mass fraction into refractive index variations, a maximum sensitivity of 5.49 nm/RIU is obtained. Moreover, given the low temperature sensitivity (1.6 pm/°C), the proposed cavity should be adequate to perform temperature independent measurements. The purity degree of glycerin is one of the most important parameters to be determined in applications such as in pharmaceutical or cosmetic area. The proposed sensor can be an alternative to the previously developed ones.