Xuan Thang of Trinh

Dr. Xuan Thang of Trinh


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2024 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
HTHoang Tuan
Hoang Tuan
PHPham Hien
Pham Hien
XTXuan Thang of Trinh
Xuan Thang of Trinh
ALAnh Le
Anh Le
MVMinh Bui Vu
Minh Bui Vu
TBTrung Thanh Bui
Trung Thanh Bui
Intracranial hemorrhage (ICH) resulting from traumatic brain injury is a serious issue, often leading to death or long-term disability if not promptly diagnosed. Currently, doctors primarily use Computerized Tomography (CT) scans to detect and precisely locate a hemorrhage, typically interpreted by radiologists. However, this diagnostic process heavily relies on the expertise of medical professionals. To address potential errors, computer-aided diagnosis systems have been developed. In this study, we propose a new method that enhances the localization and segmentation of ICH lesions in CT scans by using multiple images created through different data augmentation techniques. We integrate residual connections into a U-Net-based segmentation network to improve the training efficiency. Our experiments, based on 82 CT scans from traumatic brain injury patients, validate the effectiveness of our approach, achieving an IOU score of 0.807 ± 0.03 for ICH segmentation using 10-fold cross-validation.

15 October 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HNHuu-Thang Nguyen
Huu-Thang Nguyen
JJJen-Tzong Jeng
Jen-Tzong Jeng
VDVan-Dong Doan
Van-Dong Doan
CDChinh-Hieu Dinh
Chinh-Hieu Dinh
VDVinh Duy Dao
Vinh Duy Dao
XTXuan Thang of Trinh
Xuan Thang of Trinh
The high sensitivity for low-frequency fields makes the tiny giant magnetoresistance (GMR) sensors suitable for high-resolution eddy-current (EC) imaging. In this work, we proposed a novel design of the miniature differential EC probe with a spin-valve GMR sensor for surface and subsurface EC imaging. The differential EC probe consists of a full-bridge GMR chip mounted vertically on the edge of a tiny printed circuit board to reduce the liftoff distance. The excitation signal is perpendicular to the sensing axis of the GMR chip, which makes it sensitive to the unbalance EC signal on the surface of a conductive sample. The miniature EC probe operated at frequencies from 5 to 65 kHz is sensitive to the hidden defects on a flat conductor. The spatial resolution and stability of the device are verified by taking the 2-D scan images over the copper film samples with hidden defects, showing that the spatial resolution is better than 2 mm for the flaw 0.5 mm below the top surface of a multilayer structure. The proposed device is useful in the detection of small surface and subsurface defects, such as cracks, metal loss, and other mechanical damages.

28 March 2019 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
JJJen-Tzong Jeng
Jen-Tzong Jeng
CLChih-Cheng Lu
Chih-Cheng Lu
HKHsiang-Wei Ku
Hsiang-Wei Ku
BHBo-Rei Huang
Bo-Rei Huang
MCMeng-Huan Chia
Meng-Huan Chia
XTXuan Thang of Trinh
Xuan Thang of Trinh

20 April 2019 in Sensors
Verified
Journal Article
Open access
PDF file
JJJen-Tzong Jeng
Jen-Tzong Jeng
XTXuan Thang of Trinh
Xuan Thang of Trinh
CHChih-Hsien Hung
Chih-Hsien Hung
Chih-Cheng LuChih-Cheng Lu
Chih-Cheng Lu
A non-contact current measurement device comprised of a GMR sensor and a ferrite ring core was investigated. The sensor chip employed a high-sensitivity spin-valve full-bridge GMR sensor of which the direct output has non-negligible hysteresis and a limited linear range. By applying an AC modulation current to modulate the output of the GMR sensor, the hysteresis was reduced, and the linear range was over ±0.5 A. The resolution for DC and quasi-static current measurement was 0.1 mA at a 10 Hz bandwidth. The output in proportion to the measured current was obtained either by demodulating the current-sensitive AC signal or by employing the filtered output of the intrinsically nonlinear spin-valve response. The proposed current sensing scheme is suitable for quasi-static current measurement from DC to over 100 Hz.

4 May 2022
Verified
Book Chapter
Closed access
PDF file
VGVan Nam Giap
Van Nam Giap
QNQuang Dich Nguyen
Quang Dich Nguyen
NTNguyen Kien Trung
Nguyen Kien Trung
SHShyh-Chour Huang
Shyh-Chour Huang
XTXuan Thang of Trinh
Xuan Thang of Trinh

27 March 2021
Verified
Book Chapter
Closed access
PDF file
VGVan-Nam Giap
Van-Nam Giap
SHShyh-Chour Huang
Shyh-Chour Huang
QNQuang Dich Nguyen
Quang Dich Nguyen
XTXuan Thang of Trinh
Xuan Thang of Trinh