Kevin Amith Mathias

Mr. Kevin Amith Mathias


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2024 in Computation
Verified
Journal Article
Open access
PDF file
SKS M Abdul Khader
S M Abdul Khader
JCJohn valerian Corda
John valerian Corda
KMKevin Amith Mathias
Kevin Amith Mathias
Gowrava Shenoy BGowrava Shenoy B
Gowrava Shenoy B
Kamarul Arifin AhmadKamarul Arifin Ahmad
Kamarul Arifin Ahmad
MZMohammad Zuber
Mohammad Zuber
Aircraft cabins have high occupant densities and may introduce the risk of COVID-19 contamination. In this study, a segment of a Boeing 767 aircraft cabin with a mixing type of air distribution system was investigated for COVID-19 deposition. A section of a Boeing 737-300 cabin, featuring four rows with 28 box-shaped mannequins, was used for simulation. Conditioned air entered through ceiling inlets and exited near the floor, simulating a mixed air distribution system. Cough droplets were modeled using the Discrete Phase Model from two locations: the centre seat in the second row and the window seat in the fourth row. These droplets had a mean diameter of 90 µm, an exhalation velocity of 11.5 m/s and a flow rate of 8.5 L/s. A high-quality polyhedral mesh of about 7.5 million elements was created, with a skewness of 0.65 and an orthogonality of 0.3. The SIMPLE algorithm and a second-order upwind finite volume method were used to model airflow and droplet dynamics. It was found that the ceiling accounted for the maximum concentration followed by the seats. The concentration of deposits was almost 50% more when the source was at window as compared to the centre seat. The Covid particles resided for longer duration when the source was at the centre of the cabin than when it was located near the widow.

3 April 2026 in Computation
Verified
Journal Article
Open access
PDF file
Gowrava Shenoy BGowrava Shenoy B
Gowrava Shenoy B
RAGHUVIR PAIRAGHUVIR PAI
RAGHUVIR PAI
KMKevin Amith Mathias
Kevin Amith Mathias
MZMohammad Zuber
Mohammad Zuber
MSManjunath M S
Manjunath M S
SKS M Abdul Khader
S M Abdul Khader
The use of computational fluid dynamics (CFD) to study hemodynamics in arteries offers significant potential for addressing complex flow problems. Due to its enhanced performance hardware and software, CFD has become an important approach for studying hemodynamics in human arteries. This approach is utilized to investigate hemodynamics and forecast risk factors for atherosclerotic lesion development and progression, including circulatory flow, and to analyze local flow fields and flow profiles resulting from geometric changes. This foundational study will aid in analyzing blood flow behavior through the abdominal aorta and the origin and courses of renal arteries, as well as investigating the causes of disorders such as atherosclerosis and hypertension. The current study investigates three idealized abdominal aorta–renal artery junction models under varying blood pressure settings. Materialise software V19 was used to extract the geometry data to create idealized 3D abdominal aorta–renal branching models. Unsteady flow simulations were performed in ANSYS Fluent, utilizing rigid walls and Newtonian and Carreau–Yasuda viscosity conditions. Oscillatory shear index (OSI) and Time-averaged wall shear stress (TAWSS) were measured to enhance understanding of atherosclerotic plaque formation and progression. Also, the effect of geometric change at the bifurcation area was explored, and it was discovered that this location causes considerable vortex forming zones. The evident velocity reduction and backflow development were seen, reducing shear stress. The findings indicate that low TAWSS < 0.4 Pa and OSI > 0.15 areas within the bifurcation region are more susceptible to atherosclerosis development.

26 March 2026 in Computation
Verified
Journal Article
Open access
PDF file
ANAbhilash H N
Abhilash H N
SKS M Abdul Khader
S M Abdul Khader
HKHarishkumar Kamat
Harishkumar Kamat
MTMasaaki Tamagawa
Masaaki Tamagawa
GKGanesh Kamath
Ganesh Kamath
Gowrava Shenoy BGowrava Shenoy B
Gowrava Shenoy B
Understanding the hemodynamics of the carotid artery is essential for assessing atherosclerotic disease progression and identifying regions vulnerable to plaque formation. Background: Disturbed flow patterns and abnormal shear stresses, particularly near the carotid bifurcation, are known to influence endothelial dysfunction; therefore, this study aims to quantify the impact of patient-specific carotid artery geometry on key hemodynamic parameters associated with atherosclerotic risk. Methods: Four patient-specific carotid artery geometries were reconstructed from medical imaging data, processed using MIMICS, and analyzed using computational fluid dynamics in ANSYS Fluent, with blood modeled as an incompressible non-Newtonian fluid using the Carreau–Yasuda viscosity model under pulsatile flow conditions; velocity streamlines, pressure distribution, time-averaged wall shear stress (TAWSS), and oscillatory shear index (OSI) were evaluated at early systole, peak systole, and peak diastole. Results: The simulations revealed complex flow behaviour, including flow reversal, pressure build-up, and low-shear regions concentrated near the carotid bulb and bifurcation, with TAWSS consistently identifying low-shear zones (<1 Pa) across all geometries and OSI exhibiting pronounced directional oscillations in models with increased curvature and wider bifurcation angles. Conclusions: These findings demonstrate that geometric characteristics such as bifurcation angle, vessel tortuosity, and asymmetry play a critical role in shaping local haemodynamics, underscoring the utility of patient-specific CFD analysis as a diagnostic and predictive tool for atherosclerotic risk assessment and supporting more informed, personalized clinical decision-making.

31 December 2024 in CFD Letters
Verified
Journal Article
Open access
PDF file
AMAnirudh Krishna Mittal
Anirudh Krishna Mittal
JCJohn valerian Corda
John valerian Corda
KMKevin Amith Mathias
Kevin Amith Mathias
SKS M Abdul Khader
S M Abdul Khader
ABAugustine B.V. Barboza
Augustine B.V. Barboza
Gowrava Shenoy BGowrava Shenoy B
Gowrava Shenoy B
The increase in pollution levels in recent years has increased the prevalence of pulmonary diseases. The accumulation of pollutant particles in the pulmonary tract is speculated to be one of the major reasons for the increase in chronic cases. This necessitates the study of the mechanism of particle deposition in human airways to develop better drug delivery systems. Aerosolized forms of drugs are commonly used to treat pulmonary diseases. The current study employed computational fluid dynamics (CFD) and discrete element method (DEM) techniques to study airflow patterns and particle deposition phenomena. An idealized 3D CAD model was developed based on available literature. A discretized finite-volume model was tested to ensure an independent solution. A user-defined function (UDF) was used to simulate realistic breathing dynamics for the respiration cycle. The aerosol particles of the calculated volume were mixed into the airflow domain. The analysis was conducted using ANSYS FLUENT CFD solver. This study found several regions of high turbulence in the upper human airways, with secondary flow structures exhibiting bifurcations and the glottal region. The study also found that the oral cavity and oropharynx regions with higher turbulence intensity had a concentrated deposition of particles. Most of the aerosol particles (5μm) were transported into the alveolar sacs, where they were absorbed into the bloodstream. The oral cavity and oropharynx have the highest pressure and particle deposition efficiency, while the trachea plays a crucial role in particle deposition during inhalation due to weak oscillatory flows and turbulence, especially in the tracheal region and lower respiratory tract. The oral cavity has the highest efficiency at 7.32%, while the trachea has the lowest at 0.4%. The overall deposition efficiency across all regions is 9.078%.This study did not account for the breakup of aerosol particles. Aerosol particles can break apart due to airflow and collisions, affecting their size and deposition efficiency. Ignoring this breakup could lead to inaccurate results, making accurate dosimetry essential for inhalation studies