Xingxing Chen

Prof. Dr. Xingxing Chen


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XCXingxing Chen
Xingxing Chen
JLJinjun Liu
Jinjun Liu
ZDZhifeng Deng
Zhifeng Deng
Shuguang SongShuguang Song
Shuguang Song
SDSixing Du
Sixing Du
DWDi Wang
Di Wang
Multiple insulated gate bipolar transistor (IGBT) open-circuit faults severely affect the reliable operation of modular multilevel converters (MMCs). The existing literatures have not provided an effective diagnosis algorithm for MMCs when multiple IGBT open-circuit faults simultaneously appear in one arm. This paper presents a diagnosis strategy to handle that condition. Fault detection and estimation of the faulty submodule (SM) number is implemented by checking the value of the arm voltage error. The faulty SMs are located by observing when the transition of their switching functions leads to an obvious change of the arm voltage error. Meanwhile, the errors between the measured and predicted capacitor voltages are utilized to accelerate the localization. All of the faulty SMs can be quickly located one by one within several control cycles by using the proposed localization method. Simulation and experimental results demonstrate the validity of the proposed diagnosis strategy.

23 August 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
SOShaodi Ouyang
Shaodi Ouyang
JLJinjun Liu
Jinjun Liu
YYYue Yang
Yue Yang
XCXingxing Chen
Xingxing Chen
Shuguang SongShuguang Song
Shuguang Song
HWHongda Wu
Hongda Wu
The grounding of low frequency distribution transformer is a critical concern which ensures the proper operation and protection of the distribution system. The power electronic transformer (PET), as a future alternative of low frequency distribution transformer, also needs to consider the grounding. This paper is studying the operation of PET with arc suppression coil(ASC) grounding in the Y-connected medium-voltage(MV) stage. The study focus on two aspects: 1. The MV stage current stress brought by ASC is analyzed and a negative sequence current compensation method is proposed to reduce the MV stage current stress; 2. The ASC impedance adjustment range that MV stage can provide is analyzed and a virtual impedance method is proposed to achieve this adjustment. The effectiveness of the proposed ASC-PET as well as its control strategy is verified by both simulation and experiment results.

19 June 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
SOShaodi Ouyang
Shaodi Ouyang
JLJinjun Liu
Jinjun Liu
YYYue Yang
Yue Yang
XCXingxing Chen
Xingxing Chen
Shuguang SongShuguang Song
Shuguang Song
HWHongda Wu
Hongda Wu

23 March 2020 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XCXingxing Chen
Xingxing Chen
JLJinjun Liu
Jinjun Liu
Shuguang SongShuguang Song
Shuguang Song
SOShaodi Ouyang
Shaodi Ouyang
This paper first analyzes the effect of the level-increased nearest level modulation (NLM) to the circulating current of the modular multilevel converter (MMC). The total inserted submodule (SM) number in one phase-leg of the MMC is variable using the level-increased NLM, which can significantly increase the peak-to-peak value of the circulating harmonic currents. Then a circulating harmonic currents suppression method is proposed by applying deadbeat control for the MMC with level-increased NLM. Compared with the existing direct circulating current control approaches for the MMC, the proposed method presents specific extension and adjustment principle of the total inserted SM number. Therefore, the proposed method can improve the dynamic control performance and handle large circulating harmonic currents at steady state. And it can well coordinate the modulation and circulating harmonic currents suppression stages to avoid disturbing the ac-side output voltage while regulating the circulating current. The effectiveness of the proposed method is evaluated by a single-phase industrial-level simulated MMC system and a laboratory experimental platform.

21 November 2018 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
XCXingxing Chen
Xingxing Chen
JLJinjun Liu
Jinjun Liu
Shuguang SongShuguang Song
Shuguang Song
SOShaodi Ouyang
Shaodi Ouyang
HWHongda Wu
Hongda Wu
YYYue Yang
Yue Yang

9 November 2023 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
QSQingchao Song
Qingchao Song
XCXingxing Chen
Xingxing Chen
JLJunwei Liu
Junwei Liu
JCJiawei Chen
Jiawei Chen
KLKa Hong Loo
Ka Hong Loo
With the increasing penetration of renewable generation, producing renewable hydrogen by water electrolysis has become a promising development. For hydrogen production systems integrated with renewable energy sources (RESs), alkaline electrolyzers (AELs), and energy storage devices, its energy management system (EMS) not only controls the RESs’ operating points to capture more renewable energy but also regulates the AELs and energy storage devices’ operating power to achieve dc bus voltage regulation, dynamic power sharing, power regulation of AELs, state-of-charge regulation of energy storage devices, etc. In this article, a decentralized EMS is proposed to achieve the above objectives. The proposed EMS can indirectly improve the system's efficiency and service life by ensuring that the AEL's operating power is always above the minimum recommended operating power and it only absorbs the low-frequency part of renewable power fluctuations. Besides, the proposed EMS can reduce system costs and enhance system reliability by eliminating communication networks. Furthermore, the operational principle of the proposed EMS and the system design and analysis are elaborated. The proposed EMS's effectiveness is verified by hardware-in-the-loop real-time simulations.