Artificial lung technology is advancing at a startling rate raising hopes that it would better serve the needs of those requiring respiratory support. Whether to assist the healing of an injured lung, support patients to lung transplantation, or to entirely replace native lung function, safe and effective artificial lungs are sought. After 200 years of bioengineering progress, artificial lungs are closer than ever before to meet this demand which has risen exponentially due to the COVID-19 crisis. In this review, the critical advances in the historical development of artificial lungs are detailed. The current state of affairs regarding extracorporeal membrane oxygenation, intravascular lung assists, pump-less extracorporeal lung assists, total artificial lungs, and microfluidic oxygenators are outlined.
Thin-film composite (TFC) carbon molecular sieve (CMS) membranes offer a promising combination of excellent gas separation performance, plasticization resistance, and ease of fabrication but their broad deployment requires addressing defect formation and mechanical stability that are amplified at high pyrolysis temperatures >650 °C. Here, we focus on employing vapor phase infiltration (VPI) to tighten the surface micropores (within 10-30 nm depth) of mechanically robust selective layers of TFC CMS membranes fabricated at a moderate pyrolysis temperature of 615 °C. We systematically investigated the impact of VPI process temperature (100–200 °C) and reactant vapor pressure (40–200 mTorr) using trimethylaluminum (TMA) and water vapor. While lower process temperatures (100 °C) resulted in a deeper, pressure-dependent infiltration profile, a higher temperature of 200 °C limited the modification to a thin surface skin because of faster reaction kinetics and reduced TMA solubility. Although the VPI treatment showed only a minor effect on the glass transition temperature of the precursor, it drastically slowed methanol vapor sorption dynamics. After pyrolysis, the nanohybrid CMS structure opened to allow faster methanol transport but maintained significantly enhanced swelling resistance. Gas permeation experiments revealed that the VPI treatment significantly amplified molecular sieving by steepening the kinetic diameter dependence and provided major selectivity enhancements for gas pairs with large size differences (H2/CH4 selectivities >300). These significant boosts in selectivities were, however, accompanied by a large decrease in gas permeance. This work highlights the potential of VPI to precisely tune the ultramicropore structure of mechanically stable nanohybrid CMS membranes.
The next generation of bioelectronic interfaces demands materials that integrate biocompatibility, robust electrochemical performance and architectural functionality. Here, we introduce a low‐temperature fabrication approach for patterned titanium oxide‐coated titanium carbide nanowires (P‐TiO 2 @TiC‐NWs), utilizing room‐temperature sputter deposition, avoiding high‐temperature carbide synthesis. TiO 2 @TiC‐NWs combine the high‐aspect‐ratio architecture of TiO 2 ‐NWs with the electrochemical performance of TiC, providing a tunable platform for bioelectronic interface design. By tuning sputtering pressure and duration, distinct TiC shell morphologies and compositions were engineered. Low‐pressure deposition produced a uniform conductive shell, favoring faster charge dynamics and a more ideal capacitive response, while high‐pressure deposition generated a carbon‐rich, cauliflower‐like morphology that increased electrochemically accessible surface area. TiO 2 @TiC‐NWs reached areal capacitances of 1.01 and 2.25 mF cm −2 for 20 min deposition at 3 and 10 mTorr, respectively, compared with 117 µF cm −2 and 1.35 mF cm −2 for the corresponding planar TiC films. After 3000 cycles in physiological buffer, the 10 mTorr, 20 min sputtered sample retained 86% capacitance, while the 3 mTorr retained 75%. C2C12 myotubes cultured on P‐TiO 2 @TiC‐NW substrates exhibited preferential adhesion and directional alignment along the nanowire stripe axis, demonstrating the capacity of nanoscale surface topography to instruct anisotropic cell organization. Together, these features highlight P‐TiO 2 @TiC‐NWs as promising bioelectronic interfaces.
Thin-film composite (TFC) carbon molecular sieve (CMS) membranes offer a promising combination of excellent gas separation performance, plasticization resistance, and relative ease of fabrication but their scalable fabrication requires addressing defect formation and mechanical stability issues that are amplified at high pyrolysis temperatures >600 °C. To address these challenges, we focus on employing vapor phase infiltration (VPI) to tighten the surface micropores (within 10-30 nm depth) of mechanically robust selective layers of TFC CMS membranes fabricated at a moderate pyrolysis temperature of 615 °C. We systematically investigated the impact of VPI process temperature (100–200 °C) and reactant vapor pressure (40–200 mTorr) using trimethylaluminum (TMA) and water vapor. While lower process temperatures (100 °C) resulted in a deeper, pressure-dependent infiltration profile, a higher temperature of 200 °C limited the modification to a thin surface skin as a result of faster reaction kinetics and reduced TMA solubility. Although the VPI treatment showed only a minor effect on the glass transition temperature of the rigid precursor, it drastically altered methanol vapor sorption dynamics, reducing the diffusion coefficient by up to three orders of magnitude. After pyrolysis, the nanohybrid CMS structure opened to allow faster methanol transport but maintained significantly enhanced swelling resistance. Gas permeation experiments revealed that the VPI treatment significantly amplified molecular sieving by steepening the kinetic diameter dependence and provided major selectivity enhancements for gas pairs with large size differences (e.g., H2/CH4 selectivities up to >300). These significant boosts in selectivities were, however, accompanied by a large decrease in gas permeance which will need to be addressed to enhance the practicality of the nanohybrid CMS membranes. This work highlights the potential of VPI to precisely tune the ultramicropore structure of mechanically stable, moderate pyrolysis temperature CMS membranes and boost their selectivities for gas separations.
This study introduces a novel fabrication strategy that combines photolithography with printed electronics to develop high-performance photodetectors (PDs) operating in the visible spectrum. CsPbBr3 perovskite quantum dot (QD)-based PDs with varying layer configurations were fabricated and characterized under 405 nm laser illumination at various intensities. The QDs were deposited onto pre-patterned, Au-coated substrates using a piezoelectric inkjet printer under ambient conditions. Under zero-bias operation, the optimized bilayer (2L) device exhibited an ultra-low dark current of 1.10 × 10−11 A, an elevated light current of 1.20 × 10−10 A, and an absolute photocurrent of 1.09 × 10−10 A. This configuration demonstrated excellent performance metrics, including a strong ON/OFF current ratio of 10.91, a calculated responsivity of 1.36 × 10−9 A/W, and a shot-noise-limited specific detectivity of 6.07 × 105 Jones. Furthermore, the device showed stable, self-powered operation under visible light, confirming its energy-efficient sensing capabilities. This work highlights the immense potential of hybrid lithographic and printing techniques for producing low-cost, scalable, and flexible perovskite-based photodetectors, providing a promising framework for next-generation optoelectronic systems, including wearable and environmental sensing technologies.