Shihao Chen

Prof. Dr. Shihao Chen


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2019 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
NLNan-Ji Lu
Nan-Ji Lu
DCDing Chen
Ding Chen
LCLe-Le Cui
Le-Le Cui
LWLin Wang
Lin Wang
SCShihao Chen
Shihao Chen
QWQin-Mei Wang
Qin-Mei Wang
PURPOSE: To assess the repeatability of epithelial, stromal, and total corneal thickness measurements with spectral-domain optical coherence tomography (SD-OCT; RTVue-XR; Optovue, Inc., Fremont, CA) in patients with myopia, keratoconus, and corneas after transepithelial photorefractive keratectomy (PRK), small incision lenticule extraction (SMILE), and femtosecond laser–assisted in situ keratomileusis (FS-LASIK). METHODS: A total of 352 eyes of 352 patients (75 myopic, 68 post-transepithelial PRK, 61 post-SMILE, 75 post-FS-LASIK, 20 mild keratoconus, and 53 advanced keratoconus eyes) were included. The epithelial, stromal, and total corneal thickness were recorded from the pachymetric map in the following four zones: (1) central 2-mm region, (2) eight paracentral regions within 2- to 5-mm diameter, (3) eight midperipheral regions within 5- to 7-mm diameter, and (4) eight peripheral regions within 7- to 9-mm diameter. Three successive scans were performed to evaluate the repeatability. RESULTS: For all zones up to 9-mm diameter, the coefficient of variation (CoV) for epithelial thickness measurements ranged from 1.7% to 3.5% for myopia, 2.6% to 6.2% for post-transepithelial PRK, 2.3% to 4.7% for post-SMILE, 4.0% to 6.3% for post-FS-LASIK, 2.5% to 6.2% for mild keratoconus, and 3.5% to 8.0% for advanced keratoconus. The CoV for stromal and total thickness measurements ranged from 0.2% to 2.0% for myopia, 0.7% to 4.2% for post-transepithelial PRK, 0.3% to 2.4% for post-SMILE, 0.3% to 1.9% for post-FS-LASIK, 0.6% to 3.0% for mild keratoconus, and 1.0% to 5.9% for advanced keratoconus. CONCLUSIONS: RTVue-XR SD-OCT showed excellent repeatability when generating the pachymetric map in myopic eyes. Measurements, especially for epithelial thickness, were relatively more variable for corneas with keratoconus and those having undergone keratorefractive surgery. [ J Refract Surg. 2019;35(9):600–605.]

13 April 2023 in American Journal of Ophthalmology
Verified
Journal Article
Open access
Riccardo VinciguerraRiccardo Vinciguerra
Riccardo Vinciguerra
RARENATO AMBROSIO
RENATO AMBROSIO
YWYan Wang
Yan Wang
FZFengju Zhang
Fengju Zhang
XZXingtao Zhou
Xingtao Zhou
PVPaolo Vinciguerra
Paolo Vinciguerra
The aim of this study was to introduce an optimized version of the Corvis Biomechanical Index for Chinese populations (cCBI). Retrospective, multicenter clinical validity enhancement study. Patients were included from 7 clinics in Beijing, Shenyang, Guangzhou, Shanghai, Wenzhou, Chongqing, and Tianjin, China. Logistic regression was used to optimize the values of the constants of the CBI, based on database 1 as the development dataset (6 of 7 clinics), to create a new version of the index named cCBI. The factors of the CBI (A1Velocity, ARTh, Stiffness Parameter-A, DARatio2mm, and Inverse Integrated Radius) and the cutoff value were kept the same (0.5). With the formation of cCBI determined, it was validated on database 2 (1 of the 7 clinics). Two thousand four hundred seventy-three patients (healthy and keratoconus) were included. In database 2, the area under the curve of the cCBI was 0.985 with 93.4% specificity and 95.5% sensitivity. In the same dataset, the original CBI produced an area under the curve of 0.978 with 68.1% specificity and 97.7% sensitivity. There was a statistically significant difference between the receiver operating characteristic curve of cCBI and CBI (De Long P = .0009) CONCLUSION: The new cCBI for Chinese patients was shown to be statistically significantly better when compared with CBI to separate healthy from keratoconic eyes. The presence of an external validation dataset confirms this finding and suggests the use of cCBI in everyday clinical practice to aid in the diagnosis of keratoconus in patients who are of Chinese ethnicity.

24 October 2023 in American Journal of Ophthalmology
Verified
Journal Article
Open access
YMYuan-Yuan Miao
Yuan-Yuan Miao
XMXiao-Min Ma
Xiao-Min Ma
ZQZhan-Xin Qu
Zhan-Xin Qu
AEAshkan Eliasy
Ashkan Eliasy
BWBo-Wen Wu
Bo-Wen Wu
FBFangjun Bao
Fangjun Bao
This study seeks to evaluate the ability of the updated stress strain index (SSIv2) and other Corvis ST biomechanical parameters in distinguishing between keratoconus at different disease stages and normal eyes. Diagnostic accuracy analysis to distinguish disease stages. 1084 eyes were included and divided into groups of normal (199 eyes), forme fruste keratoconus (FFKC, 194 eyes), subclinical keratoconus (SKC, 113 eyes), mild clinical keratoconus (CKC-Ⅰ, 175 eyes), moderate clinical keratoconus (CKC-Ⅱ, 204 eyes), and severe clinical keratoconus (CKC-Ⅲ, 199 eyes). Each eye was subjected to a Corvis ST examination to determine the central corneal thickness (CCT), biomechanically corrected intraocular pressure (bIOP), SSIv2 (updated stress-strain index), and other 8 Corvis parameters including the stress-strain index (SSIv1), stiffness parameter at first applanation (SP-A1), first applanation time (A1T), Ambrósio relational thickness to the horizontal profile (ARTh), integrated inverse radius (IIR), maximum deformation amplitude (DAM), ratio between deformation amplitude at the apex and at 2 mm nasal and temporal (DARatio2), and Corvis biomechanical index (CBI). The sensitivity and specificity of these parameters in diagnosing keratoconus were analyzed through receiver operating characteristic curves. Before and after correction for CCT and bIOP, SSIv2 and ARTh were significantly higher and IIR and CBI were significantly lower in the normal group than in the FFKC group, SKC group and the 3 CKC groups (all P < .05). There were also significant correlations between the values of SSIv2, ARTh, IIR, CBI, and the CKC severity (all P < .05). AUC of SSIv2 was significantly higher than all other Corvis parameters in distinguishing normal eyes from FFKC, followed by IIR, ARTh and CBI. Corvis ST's updated stress-strain index, SSIv2, demonstrated superior performance in differentiating between normal and keratoconic corneas, and between corneas with different keratoconus stages. Similar, but less pronounced, performance was demonstrated by the IIR, ARTh and CBI.

1 July 2018 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
FBFangJun Bao
FangJun Bao
JWJunJie Wang
JunJie Wang
SCSi Cao
Si Cao
NLNa Liao
Na Liao
BSBao Shu
Bao Shu
Ahmed ElsheikhAhmed Elsheikh
Ahmed Elsheikh

8 January 2021 in Eye and Vision
Verified
Journal Article
Open access
PDF file
YLYong Li
Yong Li
ZXZhiqiang Xu
Zhiqiang Xu
QLQiaoli Liu
Qiaoli Liu
YWYuzhou Wang
Yuzhou Wang
KLKan Lin
Kan Lin
HLHu Liang
Hu Liang
Background: To explore the relationship between corneal biomechanical parameters and corneal sublayer thickness using corneal visualization Scheimpflug technology (Corvis ST) and ultrahigh-resolution optical coherence tomography (UHR-OCT) in clinical and suspected keratoconus and normal eyes.Methods: Cross-sectional prospective study. A total of 94 eyes of 70 participants were recruited. Twenty five eyes of 19 keratoconus patients, 52 eyes of 34 patients showing high risk of developing keratoconus according to the Belin/Ambrosio Enhanced Ectasia Display, and each eye of 17 normal subjects were enrolled. All participants underwent Corvis ST, Pentacam, and UHR-OCT examinations at the same time. Stiffness parameter A1 (SP-A1), deformation amplitude ratio (DA ratio), and other biomechanical parameters were recorded using Corvis ST. The vertical and horizontal thickness profiles of central 3 mm corneal epithelium, Bowman’s layer, and stroma as measured by the perpendicular distance between the neighboring interfaces were generated using UHR-OCT. The flat keratometry and steep keratometry were obtained using Pentacam. Analysis of correlation was applied to explore the association between variables.Results: Most of the biomechanical parameters and corneal sublayer thickness profiles showed statistical differences among three groups. A statistically significant linear relationship was noted between SP-A1 and DA ratio in all three groups. SP-A1 was found to be positively correlated with epithelial and Bowman’s layer thickness in the keratoconus (KC) group, and with stromal thickness in all three groups. In the normal and suspected keratoconus (SKC) groups, only stromal thickness was included in the stepwise linear regression to predict SP-A1, whereas in the KC group, steep keratometry and Bowman’s layer thickness were included.Conclusions: Significant and different correlations were noted between corneal stiffness and corneal sublayer thickness in different groups, indicating that corneal sublayers may play different roles in maintaining corneal biomechanical stability between keratoconus and normal eyes.

1 November 2023 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Open access
NLNan-Ji Md Lu
Nan-Ji Md Lu
Farhad HafeziFarhad Hafezi
Farhad Hafezi
CKCarina MD Koppen
Carina MD Koppen
JBJorge L. Alió del Barrio
Jorge L. Alió del Barrio
Ioannis M. AslanidesIoannis M. Aslanides
Ioannis M. Aslanides
Jos J. RozemaJos J. Rozema
Jos J. Rozema
Purpose: To establish a numerical spectral-domain optical coherence tomography (SD-OCT)-based keratoconus (KC) staging system and compare it with existing KC staging systems. Setting: Eye Hospital of Wenzhou Medical University, Wenzhou, China. Designs: Retrospective case-control study. Methods: Scheimpflug tomography, air-puff tonometry, and SD-OCT were performed on 236 normal and 331 KC eyes. All SD-OCT-derived parameters of the corneal epithelium and stroma were evaluated based on their receiver operating characteristic (ROC) curves, area under the curve (AUC), sensitivity, and specificity to discriminate between normal and KC eyes. The best performing parameters were subsequently used to create an OCT-based staging system, which was compared with existing tomographic and biomechanical staging systems. Results: 236 eyes from 236 normal patients and 331 eyes from 331 KC patients of different stages were included. The highest ranked AUC ROC SD-OCT parameters, derived from stroma and epithelium, were stroma overall minimum thickness (ST: AUC 0.836, sensitivity 90%, specificity 67%) and epithelium overall SD (EP: AUC 0.835, sensitivity 75%, specificity 78%). A numerical SD-OCT staging system called STEP including 2 parameters—“ST” and “EP”—with 5 stages was proposed. Conclusions: The new SD-OCT-based KC staging system is the first to take the epithelium with its sublayer stroma information into account, showing a strong agreement to the existing staging systems. This system could be incorporated into daily practice, potentially leading to an overall improvement in KC treatment and follow-up management.