Tracking and controlling microbubble (MB) dynamics in the human brain through acoustic emission monitoring during transcranial focused ultrasound therapy (tFUS) is critical for attaining safe and effective treatments. The low-amplitude MB emissions have harmonic and ultra-harmonic components, necessitating a broad bandwidth and low-noise system for monitoring transcranial MB activity. Capacitive Micromachined Ultrasonic Transducers (CMUTs) offer high sensitivity and low noise over a broad bandwidth, especially when they are tightly integrated with electronics, making them a good candidate technology for monitoring the MB activity through human skull. In this study, we designed a 16-channel Analog Front-end Electronics (AFE) with a low-noise transimpedance amplifier (TIA), a band-gap reference circuit, and an output buffer stage. To assess AFE performance and ability to detect MB acoustic emission, we combined it with a commercial CMUT array. The integrated system has 12.3 − 61.25 mV/Pa receive sensitivity with 0.085 − 0.23 mPa/ √ Hz minimum detectable pressure up to 3 MHz for a single element CMUT with 3.78 mm 2 area. Experiments with free microbubbles in a microfluidic channel demonstrate that our system is able to capture key spectral components of MBs’ harmonics when sonicated at clinically relevant frequencies (0.5 MHz) and pressures (250 kPa). Together our results demonstrate that the proposed CMUT system can support the development of novel passive cavitation detectors to track MB activity for attaining safe and effective FUS treatments.
10 June 2022 in IEEE Transactions on Biomedical Circuits and Systems
This paper presents an active impedance matching scheme that tries to optimize electrical power transfer and acoustic reflectivity in ultrasound transducers. Leveraging negative capacitance-based impedance matching would potentially improve the bandwidth and electrical power transfer while minimizing acoustic reflection of transducer elements and improve uniformity while reducing acoustic crosstalk of transducer arrays. A 16-element transceiver front-end is designed which employs an element-level active capacitive impedance cancellation scheme using an element-level negative impedance converter. The ASIC fabricated in 180-nm HVBCD technology provides high-voltage pulses up to 60 V consuming 3.6 mW and occupying 2.5 mm 2 . The front-end ASIC is used with a 1-D capacitive micromachined ultrasonic transducer (CMUT) array and its acoustical reflectivity reduction and imaging capabilities have successfully been demonstrated through pulse-echo measurements and acoustic imaging experiments.
4 June 2024 in IEEE Transactions on Biomedical Circuits and Systems
Intravascular ultrasound (IVUS) imaging catheters are significant tools for cardiovascular interventions, and their use can be expanded by realizing IVUS imaging guidewires and microcatheters. The miniaturization of these devices creates challenges in SNR due to the need for higher frequencies to provide adequate resolution. An integrated IVUS system with transmit beamforming can mitigate these limitations. This work presents the first practical highly integrated system-on-a-chip (SoC) with plane wave transmit beamforming at 40 MHz for IVUS on guidewire or microcatheters. The front-end circuitry has a 20-channel ultrasound transmitter (Tx) and receiver (Rx) array interfaced with a capacitive micromachined ultrasound transducer (CMUT) array. During each firing, all 20 Tx are excited with the same analog delay with respect to each other, which can be continuously adjusted between ~0 and 10 ns in two directions, generating a steerable plane wave in a range of ±/-50° for a phased array at 40 MHz. The unit delays are generated via a voltage-controlled delay line (VCDL), which only needs two external controls, one tuning the unit delay and the other determining the steering direction. The SoC is fabricated using a 180-nm high-voltage (HV) CMOS process and features a slender active area of 0.3 mm × 3.7 mm. The proposed SoC consumes 31.3 mW during the receiving mode. The beamformer’s functionality and the SoC’s overall performance were validated through acoustic characterization and imaging experiments.
21 June 2024 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Focused ultrasound (FUS) combined with microbubbles (MBs) has emerged as a promising strategy for transiently opening the blood-brain barrier (BBB) to enhance drug permeability in the brain. Current FUS systems for BBB opening use piezoelectric transducers as transmitters and receivers. While capacitive micromachined ultrasonic transducers (CMUTs) have been suggested as a FUS receiver alternative due to their broad bandwidth, their capabilities as transmitters have not been investigated. This is mainly due to the intrinsic nonlinear behavior of CMUTs which complicates the detection of MB generated harmonic signals and their low pressure output at FUS frequencies. Various methods have been proposed to mitigate CMUT nonlinearity; however, these approaches have primarily targeted contrast enhanced ultrasound imaging. In this study, we propose the use of polyphase modulation (PM) technique to isolate MB emissions when CMUTs are employed as transmitters for BBB opening. Our calculations for a human scale FUS system with multiple CMUT transmitters show that 10 kPa peak negative pressure at 150 mm focal distance will be sufficient for MB excitation for BBB opening. Experimental findings indicate that this pressure level can be easily generated at 400-800 kHz using a readily available CMUT. Furthermore, more than 50 dB suppression of the fundamental harmonic signal is obtained in free field and transcranial hydrophone measurements by processing receive signals in response to phase modulated transmit waveforms. In-vitro validation of PM is also conducted using Definity MB flowing through a tube phantom. MB-filled tube phantoms show adequate nonlinear signal isolation and SNR for MB harmonic detection. Together our findings indicate that PM can effectively mitigate CMUT harmonic generation, thereby creating new opportunities for wideband transmission and receive operation for BBB opening in clinical and preclinical applications.
Objective. To evaluate the efficiency of ultrasound transmission and its associated thermal effects on the skull, introducing a figure of merit (FOM) to assess the efficacy and safety of transcranial focused ultrasound (tFUS) at varying incidence angles and frequencies. Approach . A coupled elastic-thermal analysis was performed using a two-dimensional (2D) parallel solid plate skull model, validated through three-dimensional simulations. High-resolution micro-computed tomography (microCT) data from an ex vivo human skull sample was incorporated for realistic modeling. Simulations were conducted at frequencies of 0.8 MHz, 1 MHz, and 1.2 MHz to explore the impact of skull thickness, incidence angle, and absorption properties on ultrasound transmission and heating. The FOM was calculated for each scenario to provide an integrated measure of transmission efficiency and thermal safety. Experimental studies using the same ex vivo human skull validated the microCT-based simulation model. Main results . The FOM analysis demonstrated that at 0.8 MHz for an 8 mm thick skull, the FOM dropped by half for incidence angles above 15°, indicating reduced ultrasound transmission and heightened temperature rise at oblique angles. These findings suggest that dual-mode conversion at higher angles may not be suitable for tFUS applications, supporting the clinical preference for near-normal incidence. The validated 2D microCT model provides a reliable framework for studying the interplay between transmission and heating effects. Significance . This study provides an integrated framework for optimizing tFUS parameters by balancing transmission efficiency and thermal safety. The introduced FOM offers a novel metric to guide therapeutic applications, contributing to safer and more effective transcranial ultrasound treatments.