Coskun Tekes

Dr. Coskun Tekes

Department of Electrical and Computer Engineering, Kennesaw State University, Marietta, GA, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2020 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JLJaemyung Lim
Jaemyung Lim
CTCoskun Tekes
Coskun Tekes
EAEvren F. Arkan
Evren F. Arkan
ARAhmad Rezvanitabar
Ahmad Rezvanitabar
FDF. Levent Degertekin
F. Levent Degertekin
MGMaysam Ghovanloo
Maysam Ghovanloo
In this article, we present a highly integrated guidewire ultrasound (US) imaging system-on-a-chip (GUISoC) for vascular imaging. The SoC consists of a 16-channel US transmitter (Tx) and receiver (Rx) electronics, on-chip power management IC (PMIC), and quadrature sampler. Using a synthetic aperture imaging algorithm, a Tx/Rx pair, connected to capacitive micromachined ultrasound transducers (CMUTs), can be activated at any time. The Tx generates acoustic waves by driving the CMUT, while the Rx picks up the echo signal and amplify it to be delivered through an interconnect that is driven by a buffer. On-chip logic controls the pulsers that generate the high-voltage (HV)-pulse for Tx. An on-chip PMIC provides 1.8-, 5-, 39-, and 44-V supplies and a clock signal from the two interconnects besides GND. A quadrature sampler down-converts the Rx echo signal to baseband, reducing its bandwidth requirement for the output interconnect. The system design, including transimpedance amplifier (TIA) optimization, based on the equivalent circuit of a specific CMUT is presented. The SoC was fabricated by a 0.18-μm HV CMOS process, occupying 1.5-mm 2 active area and consuming 25.2 and 44 mW from 1.8 to 44 V supplies, respectively. The US Tx and Rx show bandwidths of 32-42 and 32.7-37.5 MHz, respectively. The input-referred noise of the system was measured as 9.66 nA in band with 2-m-long 52 American Wire Gauge (AWG) wire interconnects. The functionality of the GUISoC was verified in vitro by imaging wire targets.

8 September 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
ARAhmad Rezvanitabar
Ahmad Rezvanitabar
GJGwangrok Jung
Gwangrok Jung
CTCoskun Tekes
Coskun Tekes
TCThomas M. Carpenter
Thomas M. Carpenter
DCDavid M. J. Cowell
David M. J. Cowell
FDF. Levent Degertekin
F. Levent Degertekin
This paper demonstrates hybrid sub-aperture beamforming (SAB) with time-division multiplexing (TDM) for massive interconnect reduction in ultrasound imaging systems. A single-chip front-end system prototype has been fabricated in 180-nm HV BCD technology that combines 5×1 SAB with 8×1 TDM to efficiently reduce the number of receive signal interconnects by a factor of 40. The system includes on-chip high-voltage (HV) pulsers capable of generating unipolar pulses up to 70 V in transmit (TX) mode. The receiver (RX) chain consists of a T/R switch, a variable-gain low-noise amplifier (VG-LNA) with 4-step gain control (15-32 dB) for time-gain compensation followed by a programmable switched-capacitor analog delay-and-sum beamformer. The proof-of-concept prototype operates at a 200-MHz clock frequency and the SAB provides 32-step fine delays with a maximum delay of 310 ns corresponding to better than $\lambda$ /20 delay quantization at 5 MHz. With these specifications, the SAB is capable of beam steering from 0 $^{\circ }$ to 45 $^{\circ }$ for a 5-element subarray with 150-micron pitch ( $\lambda$ /2), providing a near-ideal phased array imaging performance. The sub-aperture beamformer is followed by the TDM system where each of the 8 channels is sampled at a rate of 25 MS/s after an anti-aliasing bandpass filter. The full functionality of the prototype chip is validated through electrical and acoustic measurements on a 1-D capacitive micromachined ultrasonic transducer (CMUT) array designed for intracardiac echocardiography (ICE).

10 June 2022 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Open access
ARAhmad Rezvanitabar
Ahmad Rezvanitabar
SKSait Kilinc
Sait Kilinc
CTCoskun Tekes
Coskun Tekes
EAEvren F. Arkan
Evren F. Arkan
MGMaysam Ghovanloo
Maysam Ghovanloo
FDF. Levent Degertekin
F. Levent Degertekin
This paper presents an active impedance matching scheme that tries to optimize electrical power transfer and acoustic reflectivity in ultrasound transducers. Leveraging negative capacitance-based impedance matching would potentially improve the bandwidth and electrical power transfer while minimizing acoustic reflection of transducer elements and improve uniformity while reducing acoustic crosstalk of transducer arrays. A 16-element transceiver front-end is designed which employs an element-level active capacitive impedance cancellation scheme using an element-level negative impedance converter. The ASIC fabricated in 180-nm HVBCD technology provides high-voltage pulses up to 60 V consuming 3.6 mW and occupying 2.5 mm 2 . The front-end ASIC is used with a 1-D capacitive micromachined ultrasonic transducer (CMUT) array and its acoustical reflectivity reduction and imaging capabilities have successfully been demonstrated through pulse-echo measurements and acoustic imaging experiments.

1 October 2012
Verified
Conference Paper
Closed access
CTCoskun Tekes
Coskun Tekes
GGGokce Gurun
Gokce Gurun
MRMuhammad W. Rashid
Muhammad W. Rashid
JZJaime Zahorian
Jaime Zahorian
TXToby Xu
Toby Xu
FDF. Levent Degertekin
F. Levent Degertekin
An intravascular ultrasound (IVUS) catheter that can provide forward-viewing volumetric ultrasound images would be an invaluable clinical tool for guiding interventions in coronary arteries for treatment of chronic total occlusions (CTOs) and for helping stent deployment. Single-chip integration of front-end electronics with CMUTs is highly desirable for reduced interconnect complexity, miniaturization, and flexibility of IVUS catheters. For this purpose we use the monolithic CMUT-onCMOS integration where CMUTs are fabricated directly on top of pre-processed CMOS wafers. We have previously demonstrated the characterization and imaging performance of monolithically integrated single-chip CMUT-on-CMOS Forward looking IVUS array. Here, we present 3-D real-time volumetric imaging results on vessel mimicking and relevant biological phantoms. The fabricated single chip CMUT-on-CMOS device has 56 transmit and 48 receive array elements operating at 20 MHz with a fractional bandwidth of 50%. The imaging results demonstrate that the single-chip forward looking IVUS (FLIVUS) system with monolithically integrated electronics has potential to visualize the front view of coronary arteries.

4 June 2024 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
XZXitie Zhang
Xitie Zhang
EAEvren F. Arkan
Evren F. Arkan
CTCoskun Tekes
Coskun Tekes
SKSait Kilinc
Sait Kilinc
TWTzu-Han Wang
Tzu-Han Wang
SLShaolan Li
Shaolan Li
Intravascular ultrasound (IVUS) imaging catheters are significant tools for cardiovascular interventions, and their use can be expanded by realizing IVUS imaging guidewires and microcatheters. The miniaturization of these devices creates challenges in SNR due to the need for higher frequencies to provide adequate resolution. An integrated IVUS system with transmit beamforming can mitigate these limitations. This work presents the first practical highly integrated system-on-a-chip (SoC) with plane wave transmit beamforming at 40 MHz for IVUS on guidewire or microcatheters. The front-end circuitry has a 20-channel ultrasound transmitter (Tx) and receiver (Rx) array interfaced with a capacitive micromachined ultrasound transducer (CMUT) array. During each firing, all 20 Tx are excited with the same analog delay with respect to each other, which can be continuously adjusted between ~0 and 10 ns in two directions, generating a steerable plane wave in a range of ±/-50° for a phased array at 40 MHz. The unit delays are generated via a voltage-controlled delay line (VCDL), which only needs two external controls, one tuning the unit delay and the other determining the steering direction. The SoC is fabricated using a 180-nm high-voltage (HV) CMOS process and features a slender active area of 0.3 mm × 3.7 mm. The proposed SoC consumes 31.3 mW during the receiving mode. The beamformer’s functionality and the SoC’s overall performance were validated through acoustic characterization and imaging experiments.

11 November 2019
Verified
Conference Paper
Closed access
PDF file
TWTrevor Warnix
Trevor Warnix
HLHongkuan Lin
Hongkuan Lin
MLM. Loraine Lowder
M. Loraine Lowder
CTCoskun Tekes
Coskun Tekes
Ayse TekesAyse Tekes
Ayse Tekes
This paper presents the design phases and modeling of multi axial compliant prosthetic knee joint comprised of rigid and flexible members providing a better performance than traditional spring-loaded rigid multilink joints. Mechanism consists of monolithic compliant five bar incorporating large deflecting flexure hinges, two rigid body representing the upper and lower legs, translational spring and flexure joints simulating ankle motion. Dynamical modeling is studied by integrating pseudo rigid body modeling of small-length flexure hinge method and Lagrange equations under the assumption that link 2 (left base link) is fixed and link 3 is rotated quasi-statically at constant speed. Torsional stiffness of ankle springs is obtained by using MSC Adams simulations. Initial prototype is built by 3D printing the parts using polylactic acid (PLA) filament. Mechanism is potentially suitable for pediatric prosthetic knee systems due to its simple design, versatility and light weight.