Objective. The purpose of this study was to assess the ability of sonographic elasticity imaging to distinguish acute from chronic deep venous thrombosis (DVT). Methods. Fifty‐four patients, 26 with acute DVT and 28 with chronic DVT, were studied, and we analyzed the data in 46 patients, 23 with acute (mean age, 5.7 days) and 23 with chronic (>8 months) DVT. Scanning was performed with a 5‐MHz linear array transducer during continuous freehand external deformation of each thrombus using the ultrasound scan head. The strains in the thrombi were normalized to the average strain between the skin surface and the back wall of the vein. Relative thrombus echogenicity was measured by comparing the echogenicity of the thrombus with that of the adjacent arterial lumen. Statistical analyses were performed with the Mann‐Whitney U test and receiver operating characteristic analysis. Results. The median normalized strain magnitude for the acute cases was 2.75, with an interquartile range of 2.4 to 3.71, whereas the median normalized strain magnitude for the chronic cases was 0.94, with interquartile range of 0.48 to 1.36. The difference was highly significant (P < 10−7). The area under the receiver operating characteristic curve (Az) was 0.97 ± 0.02 (SE). The echogenicity difference between the populations was highly significant (P < 10−5), with Az of 0.92 ± 0.04. The difference between the Az values was not significant (P > .05). Conclusions. In this population, sonographic elasticity imaging performs at least as well as thrombus echogenicity. Thrombus aging using elasticity imaging would be particularly helpful in evaluating symptoms in patients with post‐thrombotic syndrome.
1 October 2005 in Ultrasound in Medicine & Biology
With use of three-dimensional power Doppler US, fractional moving blood volume was accurate and reproducible for determining renal perfusion in a porcine model. Background Three-dimensional (3D) fractional moving blood volume (FMBV) derived from 3D power Doppler US has been proposed for noninvasive approximation of perfusion. However, 3D FMBV has never bee...
PURPOSE: To use speckle decorrelation in the presence of ultrasonographic (US) contrast agent as an alternative flow measurement technique to Doppler US. MATERIALS AND METHODS: In vivo and in vitro studies were performed. A tube with flowing saline solution containing contrast agent was positioned horizontally across a US image. The amount of decorrelation between a series of images was recorded. The flow profile across the tube was generated by averaging the decorrelation values and was compared with a Doppler frequency shift image. In addition, B-mode images of six rabbit kidneys were obtained during and after intravenous injection of contrast agent. Images were analyzed to compute the correlation between successive points in time. RESULTS: The velocity profiles across the tube were parabolic, with the fastest flow rates measured in the center of the tube. In the rabbit kidneys, measurements indicated the largest decorrelation rates occurred in the larger vessels. The cortical decorrelation rates were s...