Kemal Sumser

Dr. Kemal Sumser

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in International Journal of Hyperthermia
Verified
Journal Article
Open access
FAFatemeh Adibzadeh
Fatemeh Adibzadeh
KSKemal Sumser
Kemal Sumser
Sergio CurtoSergio Curto
Sergio Curto
DYDesmond T. B. Yeo
Desmond T. B. Yeo
ASAmir A. Shishegar
Amir A. Shishegar
MPMargarethus M. Paulides
Margarethus M. Paulides
Clinical trials have demonstrated the therapeutic benefits of adding radiofrequency (RF) hyperthermia (HT) as an adjuvant to radio- and chemotherapy. However, maximum utilization of these benefits is hampered by the current inability to maintain the temperature within the desired range. RF HT treatment quality is usually monitored by invasive temperature sensors, which provide limited data sampling and are prone to infection risks. Magnetic resonance (MR) temperature imaging has been developed to overcome these hurdles by allowing noninvasive 3D temperature monitoring in the target and normal tissues. To exploit this feature, several approaches for inserting the RF heating devices into the MR scanner have been proposed over the years. In this review, we summarize the status quo in MR-guided RF HT devices and analyze trends in these hybrid hardware configurations. In addition, we discuss the various approaches, extract best practices and identify gaps regarding the experimental validation procedures for MR - RF HT, aimed at converging to a common standard in this process.

1 January 2021 in International Journal of Hyperthermia
Verified
Journal Article
Open access
Margarethus PaulidesMargarethus Paulides
Margarethus Paulides
DRDario Rodrigues
Dario Rodrigues
GBGennaro G. Bellizzi
Gennaro G. Bellizzi
KSKemal Sumser
Kemal Sumser
Sergio CurtoSergio Curto
Sergio Curto
HTHana Dobsicek Trefna
Hana Dobsicek Trefna
The success of cancer hyperthermia (HT) treatments is strongly dependent on the temperatures achieved in the tumor and healthy tissues as it correlates with treatment efficacy and safety, respectiv...

13 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Laura FarinaLaura Farina
Laura Farina
KSKemal Sumser
Kemal Sumser
Gerard van RhoonGerard van Rhoon
Gerard van Rhoon
Sergio CurtoSergio Curto
Sergio Curto
Tissue mimicking phantoms are frequently used in hyperthermia applications for device and protocol optimization. Unfortunately, a commonly experienced limitation is that their precise thermal properties are not available. Therefore, in this study, the thermal properties of three currently used QA phantoms for deep hyperthermia are measured with an “off-shelf” commercial thermal property analyzer. We have measured averaged values of thermal conductivity (k = 0.59 ± 0.07 Wm−1K−1), volumetric heat capacity (C = 3.85 ± 0.45 MJm−3K−1) and thermal diffusivity (D = 0.16 ± 0.02 mm2s−1). These values are comparable with reported values of internal organs, such as liver, kidney and muscle. In addition, a sensitivity study of the performance of the commercial sensor is conducted. To ensure correct thermal measurements, the sample under test should entirely cover the length of the sensor, and a minimum of 4 mm of material parallel to the sensor in all directions should be guaranteed.

1 January 2020 in International Journal of Hyperthermia
Verified
Journal Article
Open access
GBGennaro G. Bellizzi
Gennaro G. Bellizzi
KSKemal Sumser
Kemal Sumser
IVIva VilasBoas-Ribeiro
Iva VilasBoas-Ribeiro
Sergio CurtoSergio Curto
Sergio Curto
TDTomas Drizdal
Tomas Drizdal
Margarethus PaulidesMargarethus Paulides
Margarethus Paulides
Purpose: Thermal dose-effect relations have demonstrated that clinical effectiveness of hyperthermia would benefit from more controlled heating of the tumor. Hyperthermia treatment planning (HTP) is a potent tool to study strategies enabling target conformal heating, but its accuracy is affected by patient modeling approximations. Homogeneous phantoms models are being used that do not match the body shape of patients in treatment position and often have unrealistic target volumes. As a consequence, simulation accuracy is affected, and performance comparisons are difficult. The aim of this study is to provide the first step toward standardization of HTP simulation studies in terms of patient modeling by introducing the Erasmus Virtual Patient Repository (EVPR): a virtual patient model database. Methods: Four patients with a tumor in the head and neck or the pelvis region were selected, and corresponding models were created using a clinical segmentation procedure. Using the Erasmus University Medical Center standard procedure, HTP was applied to these models and compared to HTP for commonly used surrogate models. Results: Although this study was aimed at presenting the EVPR database, our study illustrates that there is a non-negligible difference in the predicted SAR patterns between patient models and homogeneous phantom-based surrogate models. We further demonstrate the difference between actual and simplified target volumes being used today. Conclusion: Our study describes the EVPR for the research community as a first step toward standardization of hyperthermia simulation studies.

22 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
KSKemal Sumser
Kemal Sumser
GBGennaro G. Bellizzi
Gennaro G. Bellizzi
Gerard van RhoonGerard van Rhoon
Gerard van Rhoon
Margarethus PaulidesMargarethus Paulides
Margarethus Paulides
The potential of MR thermometry (MRT) fostered the development of MRI compatible radiofrequency (RF) hyperthermia devices. Such device integration creates major technological challenges and a crucial point for image quality is the water bolus (WB). The WB is located between the patient body and external sources to both couple electromagnetic energy and to cool the patient skin. However, the WB causes MRT errors and unnecessarily large field of view. In this work, we studied making the WB MRI transparent by an optimal concentration of compounds capable of modifying T 2 * relaxation without an impact on the efficiency of RF heating. Three different T 2 * reducing compounds were investigated, namely CuSO 4 , MnCl 2 , and Fe 3 O 4 . First, electromagnetic properties and T 2 * relaxation rates at 1.5 T were measured. Next, through multi-physics simulations, the predicted effect on the RF-power deposition pattern was evaluated and MRT precision was experimentally assessed. Our results identified 5 mM Fe 3 O 4 solution as optimal since it does not alter the RF-power level needed and improved MRT precision from 0.39 ° C to 0.09 ° C. MnCl 2 showed a similar MRT improvement, but caused unacceptable RF-power losses. We conclude that adding Fe 3 O 4 has significant potential to improve RF hyperthermia treatment monitoring under MR guidance.

14 September 2022 in International Journal of Hyperthermia
Verified
Journal Article
Open access
IAIoannis Androulakis
Ioannis Androulakis
KSKemal Sumser
Kemal Sumser
MMMelanie N. D. Machielse
Melanie N. D. Machielse
LKLinetta B. Koppert
Linetta B. Koppert
AJAgnes Jager
Agnes Jager
Sergio CurtoSergio Curto
Sergio Curto
The addition of hyperthermia in the treatment of intact breast cancer with the aim to improve local response is currently in a research phase. First, optimal hyperthermia devices need to be develop...