Diana Elena Vlăduțu

Dr. Diana Elena Vlăduțu

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
APAngelica Diana Popa
Angelica Diana Popa
DVDiana Elena Vlăduțu
Diana Elena Vlăduțu
AMAdina Andreea Mirea
Adina Andreea Mirea
Târtea Daniel AdrianTârtea Daniel Adrian
Târtea Daniel Adrian
MIMihaela Ionescu
Mihaela Ionescu
VMVeronica Mercuț
Veronica Mercuț
Introduction: Dental occlusion refers to the static and dynamic relationships that are established between the teeth of the two arches and is an important factor in the homeostasis of the dento-maxillary system. The objective of the present study was to compare two digital occlusal analysis systems: the T-Scan III system and the Medit I600 intraoral scanner. Materials and Methods: The study was carried out on 20 students from the Faculty of Dental Medicine Craiova, whose dental occlusion was assessed with the T-Scan III system and with the Medit I600 intraoral scanner. Dental occlusion was assessed in the maximum intercuspation position, the edge-to-edge protrusion position, and the edge-to-edge position in right and left laterotrusion. The images of the 2D occlusal contact areas obtained by both methods were converted to .jpeg format and then transferred to Adobe Photoshop CS6 2021 (Adobe Systems, San Jose, CA, USA) for comparison. The recorded data were statistically processed. Results: Analyzing the data provided by the two digital occlusal analysis systems, it was found that the T-Scan III system provided data related to the amplitude of the occlusal forces, the surface on which they were distributed (the contact surface), the dynamics of the occlusal contacts, and the proportion in which they were distributed at the level of the two hemiarches, and the Medit I600 intraoral scanner performed an evaluation of the occlusal interface of the two arches, highlighting the extent of the contact areas with the degree of overlapping of the occlusal components. Although both methods of occlusal analysis recorded the highest values for the maximum intercuspation position, the results could not be compared. Conclusions: The two digital systems provide different data in occlusal analysis. As the T-Scan III system is considered the gold standard for occlusal analysis, more studies are needed to understand the data provided by the Medit I600 intraoral scanner and their significance.

12 March 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
APADRIAN MARCEL POPESCU
ADRIAN MARCEL POPESCU
MIMihaela Ionescu
Mihaela Ionescu
Mihaela PopescuMihaela Popescu
Mihaela Popescu
AIAlin Gabriel Ionescu
Alin Gabriel Ionescu
DVDiana Elena Vlăduțu
Diana Elena Vlăduțu
VMVeronica Mercuț
Veronica Mercuț
Background/Objectives: Excessive occlusal forces manifest in bruxism and have consequences on teeth and jaws. The aim of this study was to determine the association of bruxism with clinical and radiological signs of excessive occlusal forces, such as tooth wear, fatigue dental fissures and fractures, abfraction, masseter muscle hypertrophy, and bone apposition at the mandibular angle. Methods: This cross-sectional clinical study included 181 patients presented for treatment in a general dentistry clinic. For each patient, data were extracted from the dental chart, as follows: demographic data (sex, age, and smoking), clinical data (number of teeth present, Eichner edentulous score, TWI wear score, number of fractured teeth, number of teeth with abfraction, presence of masseter hypertrophy, presence of hypersensitivity), and radiological data (bone apposition at the mandibular angle). The patients were divided into two groups according to the presence or absence of bruxism. A binomial logistic regression model was run to determine the association between bruxism and clinical and radiological signs of excessive occlusal forces. The data were statistically processed in SPSS. Results: In total, 99 women and 82 men with mean age 44.87 ± 12.67 were included in the study. Compared to the group without bruxism, the group of patients with bruxism (39.78%) showed statistically significant higher tooth wear index (TWI) (p < 0.0005), a higher number of fractured teeth (p = 0.037), a higher number of teeth with abfraction lesions (p = 0.001), and a significantly higher bone apposition score (p < 0.0005). The binomial logistic regression model showed a high prediction bruxism score for masseter muscle hypertrophy (15 times, p < 0.0005), for tooth wear index (almost 7 times, p = 0.010), and for bone apposition score (almost 3 times, p = 0.044). Conclusions: Patients with bruxism showed masseter muscle hypertrophy, higher attrition-type tooth wear index, and more teeth with fatigue fractures and abfractions than those without bruxism. Bruxism clinical signs were positively correlated with a higher bone apposition score.

16 January 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
APADRIAN MARCEL POPESCU
ADRIAN MARCEL POPESCU
MIMihaela Ionescu
Mihaela Ionescu
DVDiana Elena Vlăduțu
Diana Elena Vlăduțu
Mihaela PopescuMihaela Popescu
Mihaela Popescu
IMIulia Roxana Marinescu
Iulia Roxana Marinescu
VMVeronica Mercuț
Veronica Mercuț
Background/Objectives: The study aimed to validate the diagnostic system proposed by the Standardized Tool for the Assessment of Bruxism (STAB) by correlating the results obtained based on questionnaire and non-instrumental and instrumental tools. Methods: The study had three stages (questionnaire, clinical examination, and electromyographic study). The subjects completed a questionnaire and clinical exam. Positive signs of bruxism included oral mucosal signs and the presence of dental wear according to the BEWE index. In stage three, sEMG was performed after allocating subjects into four groups according to the questionnaire and clinical exam results: sleep bruxism (SB), awake bruxism (AB), sleep and awake bruxism (SB AB), and no bruxism (no B). After the third stage, a new selection was made, and the subjects were divided into four groups, according to sEMG results. Diagnostic accuracy was computed for possible bruxism SB and grinding and clenching sound diagnosis, possible bruxism AB and AB acknowledgment, possible bruxism SB AB, and tooth wear index. Results: For SB, the sensitivity and specificity of the tools were the highest. The non-instrumental questionnaire and clinical assessment identified 67% of SB cases and 89% without SB. For AB, the specificity was higher (84%), while the sensitivity was lower (55%), as almost half of the subjects were not aware of the presence of AB. The tests showed a low sensitivity (15%) but a high specificity (83%) for tooth wear. The absence of tooth wear was frequently associated with the absence of bruxism, while the presence of tooth wear did not necessarily imply the existence of bruxism. Conclusions: Non-instrumental evaluation of bruxism through questionnaires and clinical exams is valuable, especially for SB. Instrumental evaluation through electromyography remains a gold standard for bruxism diagnosis.

15 March 2024 in Romanian Journal of Oral Rehabilitation
Verified
Journal Article
Open access
APAdrian Marcel Popescu
Adrian Marcel Popescu
DVDiana Elena Vlăduțu
Diana Elena Vlăduțu
PMPetre Costin Mărășescu
Petre Costin Mărășescu
MAMarina Olimpia Amărăscu
Marina Olimpia Amărăscu
Târtea Daniel AdrianTârtea Daniel Adrian
Târtea Daniel Adrian
VMVeronica Mercut
Veronica Mercut
Currently, there are several digital technologies for the manufacture of occlusal appliances used in bruxism, which may involve subtractive technologies or additive technologies. The purpose of the study is the presentation of a digital workflow for occlusal splint through CAD-CAM with 3D printing. Material and method: The technology used for the manufacture of the occlusal splint included as stages: obtaining digital models, creating the digital design of the splint, 3D printing of the splint from a rigid PMMA material, adapting the splint on dental arch and in occlusion. Results: The digital technology for the occlusal appliance was used for a patient with sleep bruxism. The patient wore the occlusal splint for 9 weeks, with positive feedback. Conclusions: The digital technology proposed for occlusal splints in bruxism is reliable, and the rigid PMMA occlusal splints 3D printed are a viable alternative to conventional occlusal appliances in bruxism.

27 November 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
APADRIAN MARCEL POPESCU
ADRIAN MARCEL POPESCU
DVDiana Elena Vlăduțu
Diana Elena Vlăduțu
MIMihaela Ionescu
Mihaela Ionescu
Târtea Daniel AdrianTârtea Daniel Adrian
Târtea Daniel Adrian
Mihaela PopescuMihaela Popescu
Mihaela Popescu
VMVeronica Mercuț
Veronica Mercuț
Background/Objectives: Bruxism is a masticatory muscle activity, phasic or tonic, with/without teeth contact, that appears in sleep or an awake state. An instrumental technique used to measure the surface electromyographic (sEMG) activity of the masseter muscle is used to diagnose bruxism activity during sleep and while awake. The objective of this study was to compare the variation in bruxism (sleep and awake) indices and masseter activity indices in low sleep bruxism and moderate sleep bruxism before and after wearing an occlusal appliance (OA) for 3 months each night. Methods: A clinical interventional study was designed in which subjects diagnosed with sleep bruxism were randomly selected to be included in the study. After the first sEMG recording, two groups were formed: a low sleep-bruxism group (number of sleep-bruxism events/h between 2 and 4) and a moderate sleep-bruxism group (number of sleep-bruxism events/h equal or higher than 4). All subjects received treatment with a 3D-printed occlusal appliance and wore it each night for 3 months, at which point the second sEMG recording was performed. For each participant of this study, a chart was created that included anamnestic data, clinical data, and sEMG data. The data were statistically analyzed with SPSS, using the Mann–Whitney U and Wilcoxon signed-rank tests. Results: A total of 21 participants were included in the final analysis, 18 women and 3 men, with a mean age of 24.5 ± 2.7 years. The OA lowered all bruxism indices in the whole group, but clusters analysis showed a significant reduction in sleep-bruxism indices in the moderate sleep-bruxism group, while in the low-bruxism group, the sleep and awake indices varied insignificantly, and the number of sleep-bruxism events/h remained constant. Conclusions: The 3D-printed occlusal appliances significantly lowered the sleep-bruxism indices and sleep masseter activity indices recorded with a portable sEMG device in the moderate sleep-bruxism group. The OA lowered the awake-bruxism indices and awake masseter activity indices in the moderate sleep-bruxism group.

20 February 2026 in Diagnostics
Verified
Journal Article
Open access
PDF file
AŞAlexandru Ştefârță
Alexandru Ştefârță
MBMihaela Roxana Botila
Mihaela Roxana Botila
ARAlexandra Alexandra Rădoi
Alexandra Alexandra Rădoi
VMVeronica Mercuț
Veronica Mercuț
MIMihaela Ionescu
Mihaela Ionescu
DVDiana Elena Vlăduțu
Diana Elena Vlăduțu
Background/Objectives: Saliva plays an essential role in maintaining the oral ecological balance, and its quantitative and qualitative characteristics may influence susceptibility to dental caries. The aim of this study was to determine susceptibility to dental caries based on the DMFT index and to establish a correlation between caries experience and salivary parameters in a group of young adults. Methods: This cross-sectional study was conducted between July and November 2025 on a sample of 87 fourth-year students from the Faculty of Dentistry in Craiova. Each participant underwent an intraoral clinical examination to determine the DMFT index. The salivary parameters assessed included unstimulated salivary flow rate, saliva consistency, salivary pH, stimulated salivary flow rate, and buffering capacity, using the GC Saliva-Check Buffer kit. Statistical analyses were performed using SPSS (Statistical Package for Social Sciences) software, version 26 (SPSS Inc., Armonk, NY, USA). Results: The mean DMFT index value for the entire sample was 8.26 ± 4.481, with higher values observed among female participants. Low salivary pH was significantly associated with higher DMFT values. Participants with low or very low buffering capacity exhibited higher DMFT values compared to those with normal capacity, indicating that a reduced ability to neutralize salivary acidity is associated with increased caries activity. Conclusions: The results indicate that salivary pH and buffering capacity are important factors in dental caries susceptibility among young adults. The integration of salivary testing into the diagnostic assessment of caries risk may contribute to personalized and effective preventive strategies.