Manuel Steinhardt

Dr. Manuel Steinhardt


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 March 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
MSManuel Steinhardt
Manuel Steinhardt
AMAlexander W. Marka
Alexander W. Marka
SZSebastian Ziegelmayer
Sebastian Ziegelmayer
MMMarcus Makowski
Marcus Makowski
RBRickmer Braren
Rickmer Braren
JGJoshua Gawlitza
Joshua Gawlitza
Chronic obstructive pulmonary disease (COPD) is one of the leading causes of death. Recent studies have underlined the importance of non-contrast-enhanced chest CT scans not only for emphysema progression quantification, but for correlation with clinical outcomes as well. As about 40 percent of the 300 million CT scans per year are contrast-enhanced, no proper emphysema quantification is available in a one-stop-shop approach for patients with known or newly diagnosed COPD. Since the introduction of spectral imaging (e.g., dual-energy CT scanners), it has been possible to create virtual non-contrast-enhanced images (VNC) from contrast-enhanced images, making it theoretically possible to offer proper COPD imaging despite contrast enhancing. This study is aimed towards investigating whether these VNC images are comparable to true non-contrast-enhanced images (TNC), thereby reducing the radiation exposure of patients and usage of resources in hospitals. In total, 100 COPD patients with two scans, one with (VNC) and one without contrast media (TNC), within 8 weeks or less obtained by a spectral CT using dual-layer technology, were included in this retrospective study. TNC and VNC were compared according to their voxel-density histograms. While the comparison showed significant differences in the low attenuated volumes (LAVs) of TNC and VNC regarding the emphysema threshold of −950 Houndsfield Units (HU), the 15th and 10th percentiles of the LAVs used as a proxy for pre-emphysema were comparable. Upon further investigation, the threshold-based LAVs (−950 HU) of TNC and VNC were comparable in patients with a water equivalent diameter (DW) below 270 mm. The study concludes that VNC imaging may be a viable option for assessing emphysema progression in COPD patients, particularly those with a normal body mass index (BMI). Further, pre-emphysema was generally comparable between TNC and VNC. This approach could potentially reduce radiation exposure and hospital resources by making additional TNC scans obsolete.

30 January 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
TLTobias Lahmer
Tobias Lahmer
GWGregor Weirich
Gregor Weirich
SPStefan Porubsky
Stefan Porubsky
SRSebastian Rasch
Sebastian Rasch
FKFlorian A. Kammerstetter
Florian A. Kammerstetter
JSJulia Slotta-Huspenina
Julia Slotta-Huspenina
Background: Economic restrictions and workforce cuts have continually challenged conventional autopsies. Recently, the COVID-19 pandemic has added tissue quality and safety requirements to the investigation of this disease, thereby launching efforts to upgrade autopsy strategies. Methods: In this proof-of-concept study, we performed bedside ultrasound-guided minimally invasive autopsy (US-MIA) in the ICU of critically ill COVID-19 patients using a structured protocol to obtain non-autolyzed tissue. Biopsies were assessed for their quality (vitality) and length of biopsy (mm) and for diagnosis. The efficiency of the procedure was monitored in five cases by recording the time of each step and safety issues by swabbing personal protective equipment and devices for viral contamination. Findings: Ultrasound examination and tissue procurement required a mean time period of 13 min and 54 min, respectively. A total of 318 multiorgan biopsies were obtained from five patients. Quality and vitality standards were fulfilled, which not only allowed for specific histopathological diagnosis but also the reliable detection of SARS-CoV-2 virions in unexpected organs using electronic microscopy and RNA-expressing techniques. Interpretation: Bedside multidisciplinary US-MIA allows for the fast and efficient acquisition of autolytic-free tissue and offers unappreciated potential to overcome the limitations of research in postmortem studies.

1 December 2025 in Radiology: Cardiothoracic Imaging
Verified
Journal Article
Closed access
FGFlorian Gassert
Florian Gassert
HBHenriette Bast
Henriette Bast
TUTheresa Urban
Theresa Urban
RSRafael Schick
Rafael Schick
MLMaximilian E. Lochschmidt
Maximilian E. Lochschmidt
DPDaniela Pfeiffer
Daniela Pfeiffer
Dark-field chest radiography substantially reduced reading time without compromising sensitivity for pneumothorax detection compared with conventional radiography in clinical practice.

22 February 2024 in Bioengineering
Verified
Journal Article
Open access
PDF file
ASAndrea Steuwe
Andrea Steuwe
BKBenedikt Kamp
Benedikt Kamp
Saif AfatSaif Afat
Saif Afat
AAAlena Akinina
Alena Akinina
SASchekeb Aludin
Schekeb Aludin
BVBirte Valentin
Birte Valentin
CT protocols that diagnose COVID-19 vary in regard to the associated radiation exposure and the desired image quality (IQ). This study aims to evaluate CT protocols of hospitals participating in the RACOON (Radiological Cooperative Network) project, consolidating CT protocols to provide recommendations and strategies for future pandemics. In this retrospective study, CT acquisitions of COVID-19 patients scanned between March 2020 and October 2020 (RACOON phase 1) were included, and all non-contrast protocols were evaluated. For this purpose, CT protocol parameters, IQ ratings, radiation exposure (CTDIvol), and central patient diameters were sampled. Eventually, the data from 14 sites and 534 CT acquisitions were analyzed. IQ was rated good for 81% of the evaluated examinations. Motion, beam-hardening artefacts, or image noise were reasons for a suboptimal IQ. The tube potential ranged between 80 and 140 kVp, with the majority between 100 and 120 kVp. CTDIvol was 3.7 ± 3.4 mGy. Most healthcare facilities included did not have a specific non-contrast CT protocol. Furthermore, CT protocols for chest imaging varied in their settings and radiation exposure. In future, it will be necessary to make recommendations regarding the required IQ and protocol parameters for the majority of CT scanners to enable comparable IQ as well as radiation exposure for different sites but identical diagnostic questions.

26 November 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
SRStefan Reischl
Stefan Reischl
SZSebastian Ziegelmayer
Sebastian Ziegelmayer
MGMarkus Graf
Markus Graf
JGJoshua Gawlitza
Joshua Gawlitza
ASAndreas Sauter
Andreas Sauter
RBRickmer Braren
Rickmer Braren
Percutaneous CT-guided biopsy is a frequently performed procedure for the confirmation and molecular workup of hepatic metastases of pancreatic ductal adenocarcinoma (PDAC). Tumor necrosis of primary PDAC has shown a negative prognostic impact in recent studies. This study aims to examine predictability in CT scans and the prognostic impact of necrosis in hepatic metastases of PDAC. In this tertiary-center retrospective cohort study, we included 36 patients with hepatic metastases of PDAC who underwent CT-guided hepatic biopsies. Normalized attenuation of the biopsied metastasis was determined in venous phase contrast-enhanced planning scans obtained prior to biopsy by automatic, threshold-based 3D segmentation and manual, blinded 2D segmentation. A board-certified pathologist specialized in hepatic pathology histologically quantified the tumor necrosis and cellularity of the biopsy cylinders. We found a significant inverse-linear correlation between normalized attenuation and the fraction of necrosis (Pearson’s r = 0.51, p < 0.001 for automatic 3D segmentation or Pearson’s r = 0.52, p < 0.001 for manual 2D segmentation), whereas no correlation was found with tumor cellularity. Additionally, we discovered that patients with a fraction of necrosis ≥ 20% in metastases had a significantly shorter overall survival (p < 0.035). In summary, tumor necrosis of PDAC metastases can be estimated from contrast-enhanced CT scans, which could help to improve biopsy sample pattern planning. In addition, liver metastatic necrosis may serve as a prognostic biomarker in PDAC.