Oscar Eduardo Barreras-Calderon

Mr. Oscar Eduardo Barreras-Calderon

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 November 2024 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
JDJuan C. Delgado-Torres
Juan C. Delgado-Torres
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
OBOscar Eduardo Barreras-Calderon
Oscar Eduardo Barreras-Calderon
Nowadays, some of the most severe problems faced by health institutions are related to people’s mental health. According to the World Health Organization, approximately one billion people lived with a condition that affected their mental health in 2020, where depression, anxiety, and stress represent the most common examples. Furthermore, according to the American Psychological Association, stress aggravates the symptoms of depression and anxiety, besides having negative effects on the cardiovascular, respiratory, muscular, nervous, reproductive, endocrine, and gastrointestinal systems. It is estimated that during the COVID-19 pandemic, the number of global cases of major depressive disorder and anxiety disorders increased by 53.2 million and 76.2 million, respectively. Psychophysiology and other health disciplines, such as psychology, neurology, psychiatry, and physiotherapy, provide quantitative data from physiological signals. These signals are acquired through specialized systems that are often very expensive, with most being closed-source hardware and software. This work proposes the development of a low-cost prototype for the acquisition and visualization of a patient’s HR, ECG, EMG, GSR, and body temperature biosignals using the MAX30102, ECG AD8232, EMG Muscle T084, Grove GSR sensor, and LM35 AFEs breakout boards, respectively. Signal acquisition tests were performed with each sensor without post-processing or filtering. The test results prove that the biosignals acquired by the prototype present usability, correct morphology, stability, and can operate without errors for up to 12 h. This is expected to provide an affordable alternative to biosignal acquisition systems for educational and research institutions, offering users a similar experience to that provided by high-cost equipment, thus benefiting the training of studies.

7 November 2025 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
JDJuan C. Delgado-Torres
Juan C. Delgado-Torres
SBSonia D. Becerril-Zepeda
Sonia D. Becerril-Zepeda
KVKarla I. Vargas-Patiño
Karla I. Vargas-Patiño
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
Roberto L. AvitiaRoberto L. Avitia
Roberto L. Avitia
The development of wearable devices continues to be a growing trend. The mobile health wearables market is extremely fast-moving, with wearable ECG designs demanding increasingly complex features from manufacturers, such as size reduction, high accuracy, low weight, power efficiency, and good signal quality. The AD823X integrated circuits for ECG miniaturization, as an analog front-end (AFE), provide an amplified and filtered analog signal for subsequent digitization. The aim of this work is the development of expansion boards for portable ECG applications based on the AD823X microchip and the Arduino platform. This study includes three different circuit designs for specific ECG applications: cardiac monitor, ECG fitness, and Holter monitor. It also presents designs using both AD823X integrated circuits. After performing tests with analog stage, the Atmega328 microcontroller was used for the analog-to-digital conversion of the ECG signals, and a miniaturized custom breakout board was developed for each ECG application, incorporating a CSR BC417143 chip for Bluetooth connectivity. The digitized signals can be transmitted by serial cable, via Bluetooth to a PC, or to an Android smartphone system for visualization. Other performed tests included measuring the noise induced during the analog-to-digital conversion stage of the Atmega328 microcontroller. This work evaluated, compared, and determined the best of the applications proposed by the manufacturer of the AD8232X for a wearable ECG monitor, addressing the current needs of the devices and emerging trends in mobile health.

20 October 2026 in Drones
Verified
Journal Article
Open access
PDF file
Eladio Altamira ColadoEladio Altamira Colado
Eladio Altamira Colado
Daniel Cuevas-GonzálezDaniel Cuevas-González
Daniel Cuevas-González
MRMarco Antonio Reyna
Marco Antonio Reyna
Juan Pablo Garcia VazquezJuan Pablo Garcia Vazquez
Juan Pablo Garcia Vazquez
JDJuan C. Delgado-Torres
Juan C. Delgado-Torres
MGMaria Luisa Gonzalez
Maria Luisa Gonzalez
While using Unmanned Aerial Vehicles (UAV) as air monitoring stations presents significant advantages over fixed stations, they present an important limitation which is the rotor wash effect, which compromises air sensors’ accuracy. This work proposes a UAV equipped with a sensor separation mechanism and evaluates the accuracy of measurements taken with a PAS-OUT-01 PM sensor placed in a UAV at different separation distances by comparing them with a fixed reference sensor. Linear models with Newey–West robust standard errors show that differences from the reference sensor are significant (p < 0.05) with high values on error metrics when the sensor is not separated from the UAV, indicating high disturbance showing MAAPE values of 1.55 rad for PM2.5 and 1.55 rad for PM10, Bias values of 86.85 µgm3 for PM2.5 and 91.00 \(\frac{\text{µg}}{\text{m}^3} \) f or PM10, and RMSE of 131 \(\frac{\text{µg}}{\text{m}^3}\) for PM2.5 and 135 \(\frac{\text{µg}}{\text{m}^3}\) for PM10. No significant differences (p ≥ 0.05) and low error were found at a 7 m separation, indicating a high agreement showing MAAPE values of 0.054 rad for PM2.5 and 0.080 rad for PM10, Bias values of 0 for PM2.5 and −0.02 \(\frac{\text{µg}}{\text{m}^3}\) for PM10, and RMSE of 0.36 \(\frac{\text{µg}}{\text{m}^3}\) for PM2.5 and 0.91 \(\frac{\text{µg}}{\text{m}^3}\) for PM10. Intermediate comparisons do not show a linear decrease in the significance of the differences and error metrics. Additionally, flight tests showed that the UAV achieves a mean flight time of 14 min and a mean autonomous landing deviation of 1.55 m while carrying the proposed mechanism fully retracted.