In brain–computer interface (BCI) systems, steady-state visual-evoked potentials (SSVEP) and P300 responses have achieved widespread implementation owing to their superior information transfer rates (ITR) and minimal training requirements. These neurophysiological signals have exhibited robust efficacy and versatility in external device control, demonstrating enhanced precision and scalability. However, conventional implementations predominantly utilise liquid crystal display (LCD)-based visual stimulation paradigms, which present limitations in practical deployment scenarios. This investigation presents the development and evaluation of a novel light-emitting diode (LED)-based dual stimulation apparatus designed to enhance SSVEP classification accuracy through the integration of both SSVEP and P300 paradigms. The system employs four distinct frequencies—7 Hz, 8 Hz, 9 Hz, and 10 Hz—corresponding to forward, backward, right, and left directional controls, respectively. Oscilloscopic verification confirmed the precision of these stimulation frequencies. Real-time feature extraction was accomplished through the concurrent analysis of maximum Fast Fourier Transform (FFT) amplitude and P300 peak detection to ascertain user intent. Directional control was determined by the frequency exhibiting maximal amplitude characteristics. The visual stimulation hardware demonstrated minimal frequency deviation, with error differentials ranging from % to % across all frequencies. The implemented signal processing algorithm successfully discriminated between all four stimulus frequencies whilst correlating them with their respective P300 event markers. Classification accuracy was evaluated based on correct task intention recognition. The proposed hybrid system achieved a mean classification accuracy of %, coupled with an average ITR of bits per minute (bpm). These performance metrics notably exceed the conventional 70% accuracy threshold typically employed in BCI system evaluation protocols.
1 January 2026 in Advances in Human-Computer Interaction
The rapid proliferation of wearable health technologies for older adults has not been matched by sustained adoption. Whilst existing literature predominantly focuses on theoretical acceptance models, it provides limited empirical guidance for practitioners seeking to improve usability. This systematic review analyses the usability and acceptance of wearable health devices amongst older adults aged 65 and older to identify usability challenges. Adhering to PRISMA protocols, we systematically searched Web of Science, CINAHL Complete, PubMed Central, Scopus, JMIR, IEEE Xplore, MDPI, SpringerLink, Taylor & Francis, and the ACM Digital Library for studies published between 2014 and 2025 evaluating the usability and/or acceptance of consumer wearable health technologies. Data extraction focused on usability challenges, acceptance frameworks, device ergonomics, and ecosystem integration. Of the 446 records identified, 11 studies involving 727 participants met the inclusion criteria. Key findings revealed predominant reliance on psychological models over engineering‐focused usability research. Significant gaps emerged in physical design studies despite their influence on long‐term use. Unstandardised training approaches limited scalability, and fragmented methodologies impeded evidence synthesis. Future research requires standardised evaluation frameworks, materials‐focused usability studies, and longitudinal analyses. We propose an interdisciplinary research agenda bridging behavioural science and engineering design to enhance evidence‐based development for geriatrics.
Brain–computer interfaces (BCIs) offer transformative potential for individuals with severe motor impairments, yet single-paradigm systems remain constrained by classification inaccuracies and susceptibility to signal degradation. This pilot study presents a four-class hybrid SSVEP + P300 BCI system for discrete smart-environment device control, employing a custom-designed 240-element individually addressable NeoPixel LED matrix platform as a novel stimulation architecture. The platform supports simultaneous multi-frequency SSVEP stimulation and event-related P300 cueing within a unified hardware array, whilst its 24-bit colour rendering capability, supporting up to 16 million distinct colours and synchronised multi-unit animations, affords substantial extensibility beyond conventional single-paradigm stimulus systems. Hardware-level frequency verification confirmed accurate stimulus generation across all target frequencies, with a maximum deviation of 0.044% from nominal programmed values. Five healthy participants performed ON/OFF control tasks directed towards a fan and lamp across 3 s and 5 s EEG analysis windows, yielding 400 trials in total. Preliminary descriptive analysis suggests that the hybrid SSVEP + P300 paradigm maintained consistent group mean classification accuracy of 79.0% across both window durations, whilst the SSVEP-only condition exhibited a 7.0 percentage point decline from 79.0% to 72.0% at the extended window. As the two conditions were recorded in separate sessions and the P300 stage functions as a veto gate that cannot increase accuracy, this difference is interpreted cautiously. At the 5 s analysis window, the hybrid paradigm additionally demonstrated a conservative error profile characterised by predominant false negative over false positive activations, with a lower false positive rate than the SSVEP-only condition (8.0% vs. 12.0%). These exploratory findings from a proof-of-concept pilot investigation suggest potential suitability of the proposed approach for reliable and safety-conscious assistive device control, pending validation through larger-scale confirmatory studies with formal statistical analysis.