Federico Mereu

Mr. Federico Mereu

Università Campus Bio-Medico di Roma
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2021 in Sensors
Verified
Journal Article
Open access
PDF file
FMFederico Mereu
Federico Mereu
Francesca LeoneFrancesca Leone
Francesca Leone
CGCosimo Gentile
Cosimo Gentile
Francesca CordellaFrancesca Cordella
Francesca Cordella
EGEmanuele Gruppioni
Emanuele Gruppioni
LZLoredana Zollo
Loredana Zollo
The evolution of technological and surgical techniques has made it possible to obtain an even more intuitive control of multiple joints using advanced prosthetic systems. Targeted Muscle Reinnervation (TMR) is considered to be an innovative and relevant surgical technique for improving the prosthetic control for people with different amputation levels of the limb. Indeed, TMR surgery makes it possible to obtain reinnervated areas that act as biological amplifiers of the motor control. On the technological side, a great deal of research has been conducted in order to evaluate various types of myoelectric prosthetic control strategies, whether direct control or pattern recognition-based control. In the literature, different control performance metrics, which have been evaluated on TMR subjects, have been introduced, but no accepted reference standard defines the better strategy for evaluating the prosthetic control. Indeed, the presence of several evaluation tests that are based on different metrics makes it difficult the definition of standard guidelines for comprehending the potentiality of the proposed control systems. Additionally, there is a lack of evidence about the comparison of different evaluation approaches or the presence of guidelines on the most suitable test to proceed for a TMR patients case study. Thus, this review aims at identifying these limitations by examining the several studies in the literature on TMR subjects, with different amputation levels, and proposing a standard method for evaluating the control performance metrics.

14 August 2024 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
ASAlessia Scarpelli
Alessia Scarpelli
ADAndrea Demofonti
Andrea Demofonti
Francesca CordellaFrancesca Cordella
Francesca Cordella
UCU. Coffa
U. Coffa
FMFederico Mereu
Federico Mereu
LZLoredana Zollo
Loredana Zollo
Upper limb amputation severely affects the quality of life of individuals. Therefore, developing closed-loop upper-limb prostheses would enhance the sensory-motor capabilities of the prosthetic user. Considering design priorities based on user needs, the restoration of sensory feedback is one of the most desired features. This study focuses on employing Transcutaneous Electrical Nerve Stimulation (TENS) as a non-invasive somatotopic stimulation technique for restoring somatic sensations in upper-limb amputees. The aim of this study is to propose two encoding strategies to elicit force and slippage sensations in transradial amputees. The former aims at restoring three different levels of force through a Linear Pulse Amplitude Modulation (LPAM); the latter is devoted to elicit slippage sensations through Apparent Moving Sensation (AMS) by means of three different algorithms, i.e. the Pulse Amplitude Variation (PAV), the Pulse Width Variation (PWV) and Inter-Stimulus Delay Modulation (ISDM). Amputees had to characterize perceived sensations and to perform force and slippage recognition tasks. Results demonstrates that amputees were able to correctly identify low, medium and high levels of force, with an accuracy above the 80% and similarly, to also discriminate the slippage moving direction with a high accuracy above 90%, also highlighting that ISDM would be the most suitable method, among the three AMS strategies to deliver slippage sensations. It was demonstrated for the first time that the developed encoding strategies are effective methods to somatotopically reintroduce in the amputees, by means of TENS, force and slippage sensations.

21 November 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
Alessandro ZompantiAlessandro Zompanti
Alessandro Zompanti
Marco SantonicoMarco Santonico
Marco Santonico
Luca VolleroLuca Vollero
Luca Vollero
SGSimone Grasso
Simone Grasso
ASAnna Sabatini
Anna Sabatini
Giorgio PennazzaGiorgio Pennazza
Giorgio Pennazza
The technological development of the last few years in the field of integrated electronic components has encouraged the use of wearable electronic devices. In the biomedical field, this improvement allows the registration and analysis of numerous values, starting from environmental parameters up to the vital parameters of a subject, without interfering with the normal daily activities of the individual. In this context, the present work is focused on the design, development and evaluation of a low power wearable and wireless electronic interface able to acquire and transmit signals generated by a gas sensor, based on electrochemical technology, to monitor air quality through the measurement of O2 and CO2 concentration. Among the existing wireless technologies, it was decided to use Bluetooth Low Energy (BLE) as it allows data transmission to multiple types of external devices, such as PCs and smartphones with low power consumption.

7 July 2026
Verified
Conference Paper
Closed access
GBGiulio Maria Bianco
Giulio Maria Bianco
ABAlberto Dellacasa Bellingegni
Alberto Dellacasa Bellingegni
FMFederico Mereu
Federico Mereu
DGDaniel Gelmini
Daniel Gelmini
MCMichele Canepa
Michele Canepa
EGEmanuele Gruppioni
Emanuele Gruppioni