LIAN XIE

Ms. LIAN XIE

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Bo FengBo Feng
Bo Feng
KDKangxuan Deng
Kangxuan Deng
LXLIAN XIE
LIAN XIE
SXShuangnan Xie
Shuangnan Xie
YKYihua Kang
Yihua Kang
Speed measurement plays an important role in many measurement and control systems in industry. A simple and efficient speed measurement method for smooth conductive specimens based on motion-induced eddy currents is studied in this paper. The speed sensor consists of a magnet and a Hall element. When the conductor moves beneath the magnet, eddy currents are generated, which further generate a secondary magnetic field that is dependent on the moving speed of the conductor. The Hall element picks up this field to determine the relative speed between the conductor and the sensor. First of all, a 2D analytical model for the induced eddy currents and corresponding magnetic fields has been proposed by solving the Maxwell’s equations using spatial Fourier transforms. Then, the change in current density and magnetic field with conductor speed is analyzed using both the analytical model and the finite element method. Speed sensing experiments were conducted on a rotating conductive disk, the results showed good agreement with the proposed analytical model. Finally, specifications such as accuracy, repeatability, linearity, and resolution of the prototype sensor have been tested.

28 December 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
Bo FengBo Feng
Bo Feng
SXShuangnan Xie
Shuangnan Xie
LXLIAN XIE
LIAN XIE
KDKangxuan Deng
Kangxuan Deng
SWShenghan Wang
Shenghan Wang
YKYihua Kang
Yihua Kang
The lift-off effect is a widely occurring phenomenon in electromagnetic nondestructive testing. The change in lift-off distance influences the signal amplitude and the stability of detection signal. The effect has been relatively well studied in conventional eddy current testing and pulsed eddy current testing, but not in motion-induced eddy current testing. In this paper, the influence of magnetizer lift-off on the distribution and intensity of the motion-induced eddy current has been analyzed based on an analytical model. Then, a semi-analytical model is proposed for fast computation of defect signals. Based on the semi-analytical model and the finite element method, the influence of lift-off on defect signal has been comprehensively studied. The proposed semi-analytical model gives results similar to those obtained by finite element method, at the same time it extensively increases the computation efficiency. Finally, motion-induced eddy current testing experiments were performed with a high-speed rotating aluminum disk. The results show that the defect signal amplitude decreases exponentially with the increase of the probe lift-off, and it is a superimposing effect of the magnet lift-off and sensor lift-off.

2 April 2024 in Sensors
Verified
Journal Article
Open access
PDF file
LXLIAN XIE
LIAN XIE
PBPrashanth Baskaran
Prashanth Baskaran
ARArtur Ribeiro
Artur Ribeiro
FAFrancisco André Corrêa Alegria
Francisco André Corrêa Alegria
HRHelena Ramos
Helena Ramos
Steel Plate Cold-Rolled Commercial (SPCC) steel is known to have long-term durability. However, it still undergoes corrosion when exposed to corrosive environments. This paper proposes an evaluation method for assessing the corrosion level of SPCC steel samples using eddy current testing (ECT), along with two different machine learning approaches. The objective is to classify the corrosion of the samples into two states: a less corroded state (state-1) and a highly corroded state (state-2). Generative and discriminative models were implemented for classification. The generative classifier was based on the Gaussian mixture model (GMM), while the discriminative model was based on the logistic regression model. The features used in the classification models are the peaks of the perturbated magnetic fields at two different frequencies. The performance of the classifiers was evaluated using metrics such as absolute error, accuracy, precision, recall, and F1 score. The results indicate that the GMM model is more conducive to categorizing states with higher levels of corrosion, while the logistic regression model is helpful in estimating states with lower levels of corrosion. Meanwhile, high classification accuracy can be achieved based on both methods using eddy current testing.

14 April 2025 in IEEE Sensors Journal
Verified
Journal Article
Closed access
LXLIAN XIE
LIAN XIE
PBPrashanth Baskaran
Prashanth Baskaran
Bo FengBo Feng
Bo Feng
DPDario Pasadas
Dario Pasadas
ARArtur Ribeiro
Artur Ribeiro
HRHelena Ramos
Helena Ramos
Detecting deeply buried subsurface defect is a challenging task for eddy current testing (ECT). This study introduces a novel ECT probe designed for the detection of deeply buried defects in conductive materials. The key innovation of this probe lies in the utilization of two identical rectangular coils coupled with a high-sensitivity Hall sensor. The configuration of the coils generates maximum magnitude of eddy current while minimizing the background magnetic field perpendicular to the specimen surface, ideally achieving zero magnetic field in the center region of probe. This design allows the probe to effectively leverage magnetic sensors with high spatial resolution and sensitivity, enabling the detection of weak magnetic field disturbances caused by subsurface defects. To optimize the probe parameters, as well as maximizing the distribution of eddy currents in the plate, a theoretical model based on the second order vector potential (SOVP) formalism was derived. Moreover, FEM simulations and experiments were conducted to evaluate the detection capabilities of the optimized probe. The experimental results demonstrate that the ECT probe is capable of reliably detecting subsurface defects, when a defect with the size of 20×1×1 mm³ locates 9 mm below the surface of a 10 mm thick stainless steel specimen.

8 June 2024 in Sensors
Verified
Journal Article
Open access
PDF file
FAFrancisco André Corrêa Alegria
Francisco André Corrêa Alegria
LXLIAN XIE
LIAN XIE
DPDario Pasadas
Dario Pasadas
The estimation of the parameters of a sinusoidal signal is of paramount importance in various applications in the fields of sensors, signal processing, parameter estimation, and device characterization, among others. The presence, in the measurement system, of non-ideal phenomena such as additive noise in the signals, phase noise in the stimulus generation, jitter in the sampling system, frequency error in the experimental setup, among others, leads to increased uncertainty and bias in the estimated quantities obtained by least squares methods and those derived from them. Therefore, from a metrological point of view, it is important to be able to theoretically predict and quantify those uncertainties in order to properly design the measurement system and its parameters, such as the number of samples to acquire or the stimulus signal amplitude to use to minimize the uncertainty in the estimated values. Previous works have shown that the presence of these non-ideal phenomena leads to increased uncertainty and bias in the estimation of the sinewave amplitude. The present work complements this knowledge by focusing specifically on the effect of phase noise and sampling jitter in the bias of the initial phase estimation of a sinusoidal signal of known frequency (three‑parameter sine fitting procedure). A theoretical derivation of the bias of initial phase estimation that takes into consideration the presence of phase noise in the sinewave is presented. Since a Taylor series approximation was used where only the first term was retained, it was necessary to validate the analytical derivations with numerical simulations using a Monte Carlo type of procedure. This process was applied to different conditions regarding the phase noise standard deviation, initial phase value, and number of samples. It is concluded that, in most scenarios, initial phase estimation using sine fitting is unbiased in the presence of phase noise or jitter. It is shown, however, that in cases of extremely high phase noise standard deviation and a very low number of samples, a bias occurs.

20 November 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LXLIAN XIE
LIAN XIE
PBPrashanth Baskaran
Prashanth Baskaran
Bo FengBo Feng
Bo Feng
FAFrancisco André Corrêa Alegria
Francisco André Corrêa Alegria
ARArtur Ribeiro
Artur Ribeiro
HRHelena Ramos
Helena Ramos
Pulsed eddy current testing (PECT) is a widely used nondestructive evaluation technique due to its broadband frequency content and ability to extract rich information from both time- and frequency-domains. However, its effectiveness in detecting deeply buried defects is limited by the weak magnetic perturbations generated by subsurface anomalies. To address this challenge, we propose a novel magnetic-field differential PECT probe combined with an advanced bispectral signal processing algorithm to enhance defect detectability and signal-to-noise ratio (SNR). The proposed probe generates a localized region with a near-zero background magnetic field and suppresses interference from the primary excitation. A ferrite core is incorporated to concentrate eddy currents, while a high-sensitivity Hall sensor is positioned within the zero-field region to selectively detect defect-induced perturbation fields. To further improve robustness against noise, bispectral analysis—a higher-order spectral technique immune to Gaussian noise—is applied to enhance signal quality and support more effective defect characterization. Finite element simulations were conducted to analyze the magnetic field and eddy current distributions of the PECT probe. The probe employs a magnetic field differential design to suppress background interference and enhance sensitivity to subsurface defects. Experimental results on aluminum specimens demonstrated successful detection of subsurface defects up to 8 mm beneath the surface. Bispectral analysis significantly improved the signal-to-noise ratio (SNR) and defect characterization, highlighting its potential for enhanced subsurface defect detection in PECT.