Jörgen Anders Eklund

Prof. Jörgen Anders Eklund

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 October 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Carl Mikael LindCarl Mikael Lind
Carl Mikael Lind
JDJose Antonio Diaz-Olivares
Jose Antonio Diaz-Olivares
KLKaj Lindecrantz
Kaj Lindecrantz
JEJörgen Anders Eklund
Jörgen Anders Eklund
Work-related musculoskeletal disorders are a major concern globally affecting societies, companies, and individuals. To address this, a new sensor-based system is presented: the Smart Workwear System, aimed at facilitating preventive measures by supporting risk assessments, work design, and work technique training. The system has a module-based platform that enables flexibility of sensor-type utilization, depending on the specific application. A module of the Smart Workwear System that utilizes haptic feedback for work technique training is further presented and evaluated in simulated mail sorting on sixteen novice participants for its potential to reduce adverse arm movements and postures in repetitive manual handling. Upper-arm postures were recorded, using an inertial measurement unit (IMU), perceived pain/discomfort with the Borg CR10-scale, and user experience with a semi-structured interview. This study shows that the use of haptic feedback for work technique training has the potential to significantly reduce the time in adverse upper-arm postures after short periods of training. The haptic feedback was experienced positive and usable by the participants and was effective in supporting learning of how to improve postures and movements. It is concluded that this type of sensorized system, using haptic feedback training, is promising for the future, especially when organizations are introducing newly employed staff, when teaching ergonomics to employees in physically demanding jobs, and when performing ergonomics interventions.

1 November 2020 in Applied Ergonomics
Verified
Journal Article
Closed access
Carl Mikael LindCarl Mikael Lind
Carl Mikael Lind
LYLiyun Yang
Liyun Yang
Farhad AbtahiFarhad Abtahi
Farhad Abtahi
LHLars Hanson
Lars Hanson
KLKaj Lindecrantz
Kaj Lindecrantz
JEJörgen Anders Eklund
Jörgen Anders Eklund

1 September 2016 in Applied Ergonomics
Verified
Journal Article
Closed access
JKJ. Karltun
J. Karltun
KVK. Vogel
K. Vogel
MBM. Bergstrand
M. Bergstrand
JEJörgen Anders Eklund
Jörgen Anders Eklund

26 February 2019 in Ergonomics
Verified
Journal Article
Open access
LYLiyun Yang
Liyun Yang
KLKe Lu
Ke Lu
Mikael ForsmanMikael Forsman
Mikael Forsman
KLKaj Lindecrantz
Kaj Lindecrantz
FSFernando Seoane
Fernando Seoane
JEJörgen Anders Eklund
Jörgen Anders Eklund
Work metabolism (WM) can be accurately estimated by oxygen consumption (VO2), which is commonly assessed by heart rate (HR) in field studies. However, the VO2–HR relationship is influenced by individual capacity and activity characteristics. The purpose of this study was to evaluate three models for estimating WM compared with indirect calorimetry, during simulated work activities. The techniques were: the HR-Flex model; HR branched model, combining HR with hip-worn accelerometers (ACC); and HR + arm-leg ACC model, combining HR with wrist- and thigh-worn ACC. Twelve participants performed five simulated work activities and three submaximal tests. The HR + arm-leg ACC model had the overall best performance with limits of agreement (LoA) of −3.94 and 2.00 mL/min/kg, while the HR-Flex model had −5.01 and 5.36 mL/min/kg and the branched model, −6.71 and 1.52 mL/min/kg. In conclusion, the HR + arm-leg ACC model should, when feasible, be preferred in wearable systems for WM estimation. Practitioner Summary: Work with high energy demand can impair employees’ health and life quality. Three models were evaluated for estimating work metabolism during simulated tasks. The model combining heart rate, wrist- and thigh-worn accelerometers showed the best accuracy. This is, when feasible, suggested for wearable systems to assess work metabolism.

1 August 1991 in International Journal of Industrial Ergonomics
Verified
Journal Article
Closed access
JEJörgen Anders Eklund
Jörgen Anders Eklund
MLM. Liew
M. Liew

1 November 2016 in Applied Ergonomics
Verified
Journal Article
Closed access
IEI.-L. Engkvist
I.-L. Engkvist
JEJörgen Anders Eklund
Jörgen Anders Eklund
JKJ. Krook
J. Krook
MBM. Björkman
M. Björkman
ESErik Sundin
Erik Sundin