Farhad Abtahi

Dr. Farhad Abtahi

Cintec, Karolinska Institutet, Stockholm, Sweden
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Carl Mikael LindCarl Mikael Lind
Carl Mikael Lind
Farhad AbtahiFarhad Abtahi
Farhad Abtahi
Mikael ForsmanMikael Forsman
Mikael Forsman
Work-related musculoskeletal disorders (WMSDs) are a major contributor to disability worldwide and substantial societal costs. The use of wearable motion capture instruments has a role in preventing WMSDs by contributing to improvements in exposure and risk assessment and potentially improved effectiveness in work technique training. Given the versatile potential for wearables, this article aims to provide an overview of their application related to the prevention of WMSDs of the trunk and upper limbs and discusses challenges for the technology to support prevention measures and future opportunities, including future research needs. The relevant literature was identified from a screening of recent systematic literature reviews and overviews, and more recent studies were identified by a literature search using the Web of Science platform. Wearable technology enables continuous measurements of multiple body segments of superior accuracy and precision compared to observational tools. The technology also enables real-time visualization of exposures, automatic analyses, and real-time feedback to the user. While miniaturization and improved usability and wearability can expand the use also to more occupational settings and increase use among occupational safety and health practitioners, several fundamental challenges remain to be resolved. The future opportunities of increased usage of wearable motion capture devices for the prevention of work-related musculoskeletal disorders may require more international collaborations for creating common standards for measurements, analyses, and exposure metrics, which can be related to epidemiologically based risk categories for work-related musculoskeletal disorders.

15 December 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
AHAbdelakram hafid
Abdelakram hafid
SBSara Benouar
Sara Benouar
MKMalika Kedir-Talha
Malika Kedir-Talha
Farhad AbtahiFarhad Abtahi
Farhad Abtahi
MAMokhtar Attari
Mokhtar Attari
FSFernando Seoane
Fernando Seoane
Impedance Cardiography (ICG) is a non-invasive method for monitoring cardiac dynamics using Electrical Bioimpedance (EBI) measurements. Since its appearance more than 40 years ago, ICG has been used for assessing hemodynamic parameters. This paper present a measurement system based on two System on Chip (SoC) solutions and Raspberry PI, implementing both a full 3-lead ECG recorder and an impedance cardiographer, for educational and research development purposes. Raspberry PI is a platform supporting Do-It-Yourself project and education applications across the world. The development is part of Biosignal PI, an open hardware platform focusing in quick prototyping of physiological measurement instrumentation. The SoC used for sensing cardiac biopotential is the ADAS1000, and for the EBI measurement is the AD5933. The recording were wirelessly transmitted through Bluetooth to a PC, where the waveforms were displayed, and hemodynamic parameters such as heart rate, stroke volume, ejection time and cardiac output were extracted from the ICG and ECG recordings. These results show how Raspberry PI can be used for quick prototyping using relatively widely available and affordable components, for supporting developers in research and engineering education. The design and development documents, will be available on www.BiosignalPI.com, for open access under a Non Commercial-Share A like 4.0 International License.

2 June 2015 in BioMed Research International
Verified
Journal Article
Open access
PDF file
FSFernando Seoane
Fernando Seoane
SAShirin Abtahi
Shirin Abtahi
Farhad AbtahiFarhad Abtahi
Farhad Abtahi
LELars Ellegård
Lars Ellegård
GJGudmundur Johannsson
Gudmundur Johannsson
LWLeigh Ward
Leigh Ward
For several decades electrical bioimpedance (EBI) has been used to assess body fluid distribution and body composition. Despite the development of several different approaches for assessing total body water (TBW), it remains uncertain whether bioimpedance spectroscopic (BIS) approaches are more accurate than single frequency regression equations. The main objective of this study was to answer this question by calculating the expected accuracy of a single measurement for different EBI methods. The results of this study showed that all methods produced similarly high correlation and concordance coefficients, indicating good accuracy as a method. Even the limits of agreement produced from the Bland-Altman analysis indicated that the performance of single frequency, Sun’s prediction equations, at population level was close to the performance of both BIS methods; however, when comparing the Mean Absolute Percentage Error value between the single frequency prediction equations and the BIS methods, a significant difference was obtained, indicating slightly better accuracy for the BIS methods. Despite the higher accuracy of BIS methods over 50 kHz prediction equations at both population and individual level, the magnitude of the improvement was small. Such slight improvement in accuracy of BIS methods is suggested insufficient to warrant their clinical use where the most accurate predictions of TBW are required, for example, when assessing over-fluidic status on dialysis. To reach expected errors below 4-5%, novel and individualized approaches must be developed to improve the accuracy of bioimpedance-based methods for the advent of innovative personalized health monitoring applications.

14 September 2018 in Sensors
Verified
Journal Article
Open access
PDF file
KLKe Lu
Ke Lu
LYLiyun Yang
Liyun Yang
FSFernando Seoane
Fernando Seoane
Farhad AbtahiFarhad Abtahi
Farhad Abtahi
Mikael ForsmanMikael Forsman
Mikael Forsman
KLKaj Lindecrantz
Kaj Lindecrantz
This paper presents a new method that integrates heart rate, respiration, and motion information obtained from a wearable sensor system to estimate energy expenditure. The system measures electrocardiography, impedance pneumography, and acceleration from upper and lower limbs. A multilayer perceptron neural network model was developed, evaluated, and compared to two existing methods, with data from 11 subjects (mean age, 27 years, range, 21–65 years) who performed a 3-h protocol including submaximal tests, simulated work tasks, and periods of rest. Oxygen uptake was measured with an indirect calorimeter as a reference, with a time resolution of 15 s. When compared to the reference, the new model showed a lower mean absolute error (MAE = 1.65 mL/kg/min, R2 = 0.92) than the two existing methods, i.e., the flex-HR method (MAE = 2.83 mL/kg/min, R2 = 0.75), which uses only heart rate, and arm-leg HR+M method (MAE = 2.12 mL/kg/min, R2 = 0.86), which uses heart rate and motion information. As indicated, this new model may, in combination with a wearable system, be useful in occupational and general health applications.

13 July 2018 in IEEE Access
Verified
Journal Article
Open access
LYLiyun Yang
Liyun Yang
KLKe Lu
Ke Lu
JDJose A. Diaz-Olivares
Jose A. Diaz-Olivares
FSFernando Seoane
Fernando Seoane
KLKaj Lindecrantz
Kaj Lindecrantz
JEJorgen A. E. Eklund
Jorgen A. E. Eklund
Work-related musculoskeletal and cardiovascular disorders are still prevalent in today's working population. Nowadays, risk assessments are usually performed via self-reports or observations, which have relatively low reliability. Technology developments in textile electrodes (textrodes), inertial measurement units, and the communication and processing capabilities of smart phones/tablets provide wearable solutions that enable continuous measurements of physiological and musculoskeletal loads at work with sufficient reliability and resource efficiency. In this paper, a wearable system integrating textrodes, motion sensors, and real-time data processing through a mobile application was developed as a demonstrator of risk assessment related to different types and levels of workload and activities. The system was demonstrated in eight subjects from four occupations with various workload intensities, during which the heart rate and leg motion data were collected and analyzed with real-time risk assessment and feedback. The system showed good functionality and usability as a risk assessment tool. The results contribute to designing and developing future wearable systems and bring new solutions for the prevention of work-related disorders.

1 November 2020 in Applied Ergonomics
Verified
Journal Article
Closed access
Carl Mikael LindCarl Mikael Lind
Carl Mikael Lind
LYLiyun Yang
Liyun Yang
Farhad AbtahiFarhad Abtahi
Farhad Abtahi
LHLars Hanson
Lars Hanson
KLKaj Lindecrantz
Kaj Lindecrantz
JEJörgen Anders Eklund
Jörgen Anders Eklund