Intrabody communication (IBC) uses the human body as a signal transmission medium. In the capacitive coupling IBC approach, the signal is transmitted through the body, and the signal return path is closed through the environment. The received signal level is affected by the orientation of the transmitter with respect to the receiver, the number of ground electrodes connected to the body, the size of the receiver ground plane, and the surrounding environment. In this paper, we present a characterization of the capacitive IBC channel in the frequency range from 100 kHz to 100 MHz, obtained using a network analyzer and a pair of baluns. In order to better understand the transmission path in the frequency range of interest, we analyze the intrabody channel transmission characteristics using different electrode arrangements, test persons, environments, and body positions and movements. The transmission gain increases with frequency for 20 dB/dec and depends on the transmitter to the receiver distance, and the electrode arrangements. For a proper IBC configuration, the variations of the environment, test persons, body positions, and movements affect the transmission gain less than 2 dB.
1 January 2018 in Wireless Communications and Mobile Computing
Intrabody communication (IBC) is a wireless communication technology using the human body to develop body area networks (BANs) for remote and ubiquitous monitoring. IBC uses living tissues as a transmission medium, achieving power‐saving and miniaturized transceivers, making communications more robust against external interference and attacks on the privacy of transmitted data. Due to these advantages, IBC has been included as a third physical layer in the IEEE 802.15.6 standard for wireless body area networks (WBANs) designated as Human Body Communication (HBC). Further research is needed to compare both methods depending on the characteristics of IBC application. Challenges remain for an optimal deployment of IBC technology, such as the effect of long‐term use in the human body, communication optimization through more realistic models, the influence of both anthropometric characteristics and the subject’s movement on the transmission performance, standardization of communications, and development of small‐size and energy‐efficient prototypes with increased data rate. The purpose of this work is to provide an in‐depth overview of recent advances and future challenges in human body/intrabody communication for wireless communications and mobile computing.
Intrabody communication (IBC) uses the human body as a signal transmission medium. In the capacitive coupling IBC approach the signal is transmitted through the body and the signal return path is closed through the environment. The received signal level is affected by the orientation of the transmitter with respect to the receiver, the number of ground electrodes connected to the body, the size of the receiver ground plane, and the surrounding environment. In this paper we present a characterization of the capacitive IBC channel in the frequency range from 100 kHz to 100 MHz, obtained using a network analyzer and a pair of baluns. In order to better understand the transmission path in the frequency range of interest, we analyze the intrabody channel transmission characteristics using different electrode arrangements. The transmission gain increases with frequency for 20 dB/decade up to 1 MHz, and for the higher frequencies the increase depends on the transmitter to the receiver distance and the electrode arrangements.
In recent years there has been an increasing need for miniature, low-cost, commercially accessible, and user-friendly sensor solutions for wireless body area networks (WBAN), which has led to the adoption of new physical communication interfaces providing distinctive advantages over traditional wireless technologies. Ultra-wideband (UWB) and intrabody communication (IBC) have been the subject of intensive research in recent years due to their promising characteristics as means for short-range, low-power, and low-data-rate wireless interfaces for interconnection of various sensors and devices placed on, inside, or in the close vicinity of the human body. The need for safe and standardized solutions has resulted in the development of two relevant standards, IEEE 802.15.4 (for UWB) and IEEE 802.15.6 (for UWB and IBC), respectively. This paper presents an in-depth overview of recent studies and advances in the field of application of UWB and IBC technologies for wireless body sensor communication systems.
Muscle fatigue, as a common physiological phenomenon, has attracted much attention in the fields of rehabilitation and athletic training. A wearable technology for monitoring the muscle fatigue anytime and anywhere is urgently needed. In this paper we apply Electrical impedance myography (EIM) technique, usually used for non-invasive detection of neuromuscular diseases with the four-electrode array, for evaluation of the local muscle fatigue status via the variation of electrical impedance. An equivalent multilayer inhomogeneous 3D finite element model of human arm was built in order to optimize the four-electrode configuration to improve EIM detection sensitivity. Current density in muscle layer and differential potential of induction electrodes were selected as the evaluation indexes for optimization. Then the in vivo experiments of dynamic contraction with different maximal voluntary contractions (MVC) were performed on the biceps brachii muscle of eight healthy volunteers. The results showed that muscle resistance (R) decreased almost 8 Ω from the completely relaxed muscle to exhaustion, which is the same trend as for the median frequency (MF) of measured surface electromyography (sEMG) signals. The model and experiments in this paper indicate the feasibility and efficiency of EIM for detection of muscle fatigue using wearable devices.
Intra-body communication (IBC) uses the human body as the transmission medium for electrical signals, and it features the following advantages: low power consumption, strong anti-interference ability, high data security, and broad application scenarios. However, some technical issues still need to be addresses, such as the choice of the best modulation and demodulation scheme in different application scenarios, influence of human activity on IBC performance, variable signal-to-noise ratio (SNR), and influence of transmission distance change on different modulation and demodulation methods. This paper adopts direct sequence spread spectrum (DSSS) communication and phase modulation to realize DSSS-differential phase shift keying (DPSK) and DPSK modulation transmission of baseband data. Moreover, the Costas loop method is employed to achieve reliable symbol recovery. Under the same conditions, in vivo experiments were conducted to compare the performance of DSSS-DPSK and DPSK galvanic coupling IBC transceivers. Notably, these transceivers are affected by the changes in SNR, transmission distance, and human activities. Results show that the bit error rate (BER) of the DPSK scheme is 40 times larger than the DSSS-DPSK scheme in a 30 cm channel length and different SNR experiments. When the BER performance changes from extremely poor (1.40×10-1) to excellent (1.51×10-6), the SNR of DSSS-DPSK scheme only needs to be improved by 16 dB. In contrast, when the BER performance changes from extremely poor (1.54×10-1) to good (1.65×10-5), the SNR of DPSK scheme needs to be improved by 25 dB. With a SNR of –5 dB, the BER ratios of the DPSK scheme is 7 times larger than the DSSS-DPSK scheme. Also, DSSS-DPSK scheme is more sensitive to changes in motion status than DPSK.