13 January 2020 in IEEE Access
Muscle fatigue, as a common physiological phenomenon, has attracted much attention in the fields of rehabilitation and athletic training. A wearable technology for monitoring the muscle fatigue anytime and anywhere is urgently needed. In this paper we apply Electrical impedance myography (EIM) technique, usually used for non-invasive detection of neuromuscular diseases with the four-electrode array, for evaluation of the local muscle fatigue status via the variation of electrical impedance. An equivalent multilayer inhomogeneous 3D finite element model of human arm was built in order to optimize the four-electrode configuration to improve EIM detection sensitivity. Current density in muscle layer and differential potential of induction electrodes were selected as the evaluation indexes for optimization. Then the in vivo experiments of dynamic contraction with different maximal voluntary contractions (MVC) were performed on the biceps brachii muscle of eight healthy volunteers. The results showed that muscle resistance (R) decreased almost 8 Ω from the completely relaxed muscle to exhaustion, which is the same trend as for the median frequency (MF) of measured surface electromyography (sEMG) signals. The model and experiments in this paper indicate the feasibility and efficiency of EIM for detection of muscle fatigue using wearable devices.
24 September 2019 in IEEE Access
Functional electrical stimulation (FES) has been widely used in limb rehabilitation. The first step for the precision rehabilition is to clarify the variation of limb angle induced by FES. In this study, an electric stimulator and an inertial sensor are used to build a human body experimental platform. Motion characteristics of ankle angle induced by electrical stimulation pulse variation are obtained through experiment. The obtained ankle angle characteristics are used to train a neural network-based Hammerstein (H) model and the model parameters are identified by the genetic algorithm, which can effectively predict the ankle angle change induced by electrical stimulation. The structural parameters of the H model are adjusted according to the normalized root mean square error value (NRMSE) of the training data. The 10-fold cross-validation is used to verify the feasibility and effectiveness of the model. Experimental results show that the neural network-based H model can effectively predict the output change of the ankle angle induced by the electrical stimulation pulse, and its root mean square error (RMSE) and NRMSE are 2.78 ± 0.33° and 23.70 ± 1.77%, respectively. Therefore, the proposed model can provide a theoretical basis for predicting ankle angle change in an electrical stimulation closed-loop control system.