Fabrice Vaussenat

Prof. Fabrice Vaussenat

orcid
Researcher in medical data science: Medical science modeling...

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2025 in Communications Engineering
Verified
Journal Article
Open access
PDF file
AWArjun Wadhwa
Arjun Wadhwa
APAlexandre Perrotton
Alexandre Perrotton
MTMohamad Hassan Hassan Taherian
Mohamad Hassan Hassan Taherian
AZAbbas Zirakjou
Abbas Zirakjou
JBJaime Alberto Benavides-Guerrero
Jaime Alberto Benavides-Guerrero
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier
Humidity sensors are essential components in modern technology, spanning applications from residential appliances to the Internet of Things (IoT). However, conventional commercial sensors are typically rigid, constrained by narrow relative humidity (%RH) operating ranges, and require complex fabrication processes. In this study, we present a highly sensitive cubic silicon carbide (3C–SiC) nanoparticle-based relative humidity sensor, fabricated via serigraphic printing on to 5 mil thick flexible polyimide (Kapton®) substrate. Devices are tested across a broad humidity range of 10–90%RH at ambient temperature and their performance is evaluated in a controlled humidity chamber. The sensor exhibits a robust response of 45.2% R/R0, with a sensitivity of 5.34 Ω/%RH, an adsorption time of 18 seconds, and a desorption time of 46 seconds. Additionally, the device demonstrates low hysteresis of 6.5% at 60%RH, with excellent repeatability and stability over 3.5 hours of continuous cycling. To showcase their potential for real-world applications, the printed sensors are integrated into a commercial KN95 mask for monitoring respiration parameters, such as respiration rate. This integration highlights the potential for future exploration in human health monitoring, utilizing fully printed, low-cost sensing devices.

15 January 2025 in Surfaces and Interfaces
Verified
Journal Article
Open access
JBJaime A. Benavides-Guerrero
Jaime A. Benavides-Guerrero
PFPaul Fourmont
Paul Fourmont
LGLuis Felipe Gerlein
Luis Felipe Gerlein
AAAstrid C. Angel-Ospina
Astrid C. Angel-Ospina
Fiderman Machuca-MartinezFiderman Machuca-Martinez
Fiderman Machuca-Martinez
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier

3 July 2024 in Sensors
Verified
Journal Article
Open access
PDF file
Fabrice VaussenatFabrice Vaussenat
Fabrice Vaussenat
ABAbhiroop Bhattacharya
Abhiroop Bhattacharya
PBPhilippe Boudreau
Philippe Boudreau
DBDiane B. Boivin
Diane B. Boivin
GGGhyslain Gagnon
Ghyslain Gagnon
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier
Sleep disorders can have harmful consequences in both the short and long term. They can lead to attention deficits, as well as cardiac, neurological and behavioral repercussions. One of the most widely used methods for assessing sleep disorders is polysomnography (PSG). A major challenge associated with this method is all the cables needed to connect the recording devices, making the examination more intrusive and usually requiring a clinical environment. This can have potential consequences on the test results and their accuracy. One simple way to assess the state of the central nervous system (CNS), a well-known indicator of sleep disorder, could be the use of a portable medical device. With this in mind, we implemented a simple model using both the RR interval (RRI) and its second derivative to accurately predict the awake and napping states of a subject using a feature classification model. For training and validation, we used a database providing measurements from nine healthy young adults (six men and three women), in which heart rate variability (HRV) associated with light-on, light-off, sleep onset and sleep offset events. Results show that using a 30 min RRI time series window suffices for this lightweight model to accurately predict whether the patient was awake or napping.

17 September 2025 in Additive Manufacturing
Verified
Journal Article
Open access
JBJaime Alberto Benavides-Guerrero
Jaime Alberto Benavides-Guerrero
LGLuis Felipe Gerlein
Luis Felipe Gerlein
AAAstrid C. Angel-Ospina
Astrid C. Angel-Ospina
PFPaul Fourmont
Paul Fourmont
ABAbhiroop Bhattacharya
Abhiroop Bhattacharya
SCSylvain G. Cloutier
Sylvain G. Cloutier

31 March 2024 in Sensors
Verified
Journal Article
Open access
PDF file
JPJulie Payette
Julie Payette
Fabrice VaussenatFabrice Vaussenat
Fabrice Vaussenat
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier
Currently, wearable technology is an emerging trend that offers remarkable access to our data through smart devices like smartphones, watches, fitness trackers and textiles. As such, wearable devices can enable health monitoring without disrupting our daily routines. In clinical settings, electrocardiograms (ECGs) and photoplethysmographies (PPGs) are used to monitor heart and respiratory behaviors. In more practical settings, accelerometers can be used to estimate the heart rate when they are attached to the chest. They can also help filter out some noise in ECG signals from movement. In this work, we compare the heart rate data extracted from the built-in accelerometer of a commercial smart pen equipped with sensors (STABILO’s DigiPen) to standard ECG monitor readouts. We demonstrate that it is possible to accurately predict the heart rate from the smart pencil. The data collection is carried out with eight volunteers writing the alphabet continuously for five minutes. The signal is processed with a Butterworth filter to cut off noise. We achieve a mean-squared error (MSE) better than 6.685 × 10−3 comparing the DigiPen’s computed Δt (time between pulses) with the reference ECG data. The peaks’ timestamps for both signals all maintain a correlation higher than 0.99. All computed heart rates (HR =60Δt) from the pen accurately correlate with the reference ECG signals.

25 October 2023 in JMIR Biomedical Engineering
Verified
Journal Article
Open access
Fabrice VaussenatFabrice Vaussenat
Fabrice Vaussenat
ABAbhiroop Bhattacharya
Abhiroop Bhattacharya
JPJulie Payette
Julie Payette
JBJaime Alberto Benavides-Guerrero
Jaime Alberto Benavides-Guerrero
APAlexandre Perrotton
Alexandre Perrotton
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier
Background: Accurate and portable respiratory parameter measurements are critical for properly managing chronic obstructive pulmonary diseases (COPDs) such as asthma or sleep apnea, as well as controlling ventilation for patients in intensive care units, during surgical procedures, or when using a positive airway pressure device for sleep apnea. Objective: The purpose of this research is to develop a new nonprescription portable measurement device that utilizes relative humidity sensors (RHS) to accurately measure key respiratory parameters at a cost that is approximately 10 times less than the industry standard. Methods: We present the development, implementation, and assessment of a wearable respiratory measurement device using the commercial Bosch BME280 RHS. In the initial stage, the RHS was connected to the pneumotach (PNT) gold standard device via its external connector to gather breathing metrics. Data collection was facilitated using the Arduino platform with a Bluetooth Low Energy connection, and all measurements were taken in real time without any additional data processing. The device’s efficacy was tested with 7 participants (5 men and 2 women), all in good health. In the subsequent phase, we specifically focused on comparing breathing cycle and respiratory rate measurements and determining the tidal volume by calculating the region between inhalation and exhalation peaks. Each participant's data were recorded over a span of 15 minutes. After the experiment, detailed statistical analysis was conducted using ANOVA and Bland-Altman to examine the accuracy and efficiency of our wearable device compared with the traditional methods. Results: The perfused air measured with the respiratory monitor enables clinicians to evaluate the absolute value of the tidal volume during ventilation of a patient. In contrast, directly connecting our RHS device to the surgical mask facilitates continuous lung volume monitoring. The results of the 1-way ANOVA showed high P values of .68 for respiratory volume and .89 for respiratory rate, which indicate that the group averages with the PNT standard are equivalent to those with our RHS platform, within the error margins of a typical instrument. Furthermore, analysis utilizing the Bland-Altman statistical method revealed a small bias of 0.03 with limits of agreement (LoAs) of –0.25 and 0.33. The RR bias was 0.018, and the LoAs were –1.89 and 1.89. Conclusions: Based on the encouraging results, we conclude that our proposed design can be a viable, low-cost wearable medical device for pulmonary parametric measurement to prevent and predict the progression of pulmonary diseases. We believe that this will encourage the research community to investigate the application of RHS for monitoring the pulmonary health of individuals.