Luis Felipe Gerlein

Dr. Luis Felipe Gerlein

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 January 2024 in RSC Advances
Verified
Journal Article
Open access
PDF file
LGLuis Felipe Gerlein
Luis Felipe Gerlein
JBJaime Alberto Benavides-Guerrero
Jaime Alberto Benavides-Guerrero
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier
Photonic postprocess of multimaterial, highly conductive transparent electrodes. Separate annealing of AgNWs and crystallization of a TiO 2 layer atop are proved. This novelty processing results in two opposing types of materials: nanowires and titania being transformed atop a PET substrate.

19 November 2019 in Advanced Engineering Materials
Verified
Journal Article
Closed access
PDF file
LGLuis Felipe Gerlein
Luis Felipe Gerlein
JBJaime Alberto Benavides-Guerrero
Jaime Alberto Benavides-Guerrero
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier

21 May 2025 in Materials
Verified
Journal Article
Open access
LGLuis Felipe Gerlein
Luis Felipe Gerlein
MTMohamad Hassan Hassan Taherian
Mohamad Hassan Hassan Taherian
Martin BolducMartin Bolduc
Martin Bolduc
This review article provides a comprehensive analysis of the photonic sintering conditions necessary to process non-oxide ceramics, to obtain similar material properties when compared with those of thermally annealed ones, for various applications in printed electronics. This article presents a thorough examination of the scientific literature on this topic, discussing the principles of photonic sintering applied to non-oxide ceramics, its advantages over traditional post-processing methods, and a quantitative overview of the performance of devices fabricated with the crystalline materials obtained.

15 January 2025 in Surfaces and Interfaces
Verified
Journal Article
Open access
JBJaime A. Benavides-Guerrero
Jaime A. Benavides-Guerrero
PFPaul Fourmont
Paul Fourmont
LGLuis Felipe Gerlein
Luis Felipe Gerlein
AAAstrid C. Angel-Ospina
Astrid C. Angel-Ospina
Fiderman Machuca-MartinezFiderman Machuca-Martinez
Fiderman Machuca-Martinez
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier

17 September 2025 in Additive Manufacturing
Verified
Journal Article
Open access
JBJaime Alberto Benavides-Guerrero
Jaime Alberto Benavides-Guerrero
LGLuis Felipe Gerlein
Luis Felipe Gerlein
AAAstrid C. Angel-Ospina
Astrid C. Angel-Ospina
PFPaul Fourmont
Paul Fourmont
ABAbhiroop Bhattacharya
Abhiroop Bhattacharya
SCSylvain G. Cloutier
Sylvain G. Cloutier

25 October 2023 in JMIR Biomedical Engineering
Verified
Journal Article
Open access
Fabrice VaussenatFabrice Vaussenat
Fabrice Vaussenat
ABAbhiroop Bhattacharya
Abhiroop Bhattacharya
JPJulie Payette
Julie Payette
JBJaime Alberto Benavides-Guerrero
Jaime Alberto Benavides-Guerrero
APAlexandre Perrotton
Alexandre Perrotton
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier
Background: Accurate and portable respiratory parameter measurements are critical for properly managing chronic obstructive pulmonary diseases (COPDs) such as asthma or sleep apnea, as well as controlling ventilation for patients in intensive care units, during surgical procedures, or when using a positive airway pressure device for sleep apnea. Objective: The purpose of this research is to develop a new nonprescription portable measurement device that utilizes relative humidity sensors (RHS) to accurately measure key respiratory parameters at a cost that is approximately 10 times less than the industry standard. Methods: We present the development, implementation, and assessment of a wearable respiratory measurement device using the commercial Bosch BME280 RHS. In the initial stage, the RHS was connected to the pneumotach (PNT) gold standard device via its external connector to gather breathing metrics. Data collection was facilitated using the Arduino platform with a Bluetooth Low Energy connection, and all measurements were taken in real time without any additional data processing. The device’s efficacy was tested with 7 participants (5 men and 2 women), all in good health. In the subsequent phase, we specifically focused on comparing breathing cycle and respiratory rate measurements and determining the tidal volume by calculating the region between inhalation and exhalation peaks. Each participant's data were recorded over a span of 15 minutes. After the experiment, detailed statistical analysis was conducted using ANOVA and Bland-Altman to examine the accuracy and efficiency of our wearable device compared with the traditional methods. Results: The perfused air measured with the respiratory monitor enables clinicians to evaluate the absolute value of the tidal volume during ventilation of a patient. In contrast, directly connecting our RHS device to the surgical mask facilitates continuous lung volume monitoring. The results of the 1-way ANOVA showed high P values of .68 for respiratory volume and .89 for respiratory rate, which indicate that the group averages with the PNT standard are equivalent to those with our RHS platform, within the error margins of a typical instrument. Furthermore, analysis utilizing the Bland-Altman statistical method revealed a small bias of 0.03 with limits of agreement (LoAs) of –0.25 and 0.33. The RR bias was 0.018, and the LoAs were –1.89 and 1.89. Conclusions: Based on the encouraging results, we conclude that our proposed design can be a viable, low-cost wearable medical device for pulmonary parametric measurement to prevent and predict the progression of pulmonary diseases. We believe that this will encourage the research community to investigate the application of RHS for monitoring the pulmonary health of individuals.