Alexandre Perrotton

Alexandre Perrotton

Auto-generated profile, based on publicly available information

Alexandre Perrotton

Department of Electrical Engineering, École de Technologie Supérieure, Montreal, Quebec, Canada

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 May 2025 in Communications Engineering
Verified
Journal Article
Open access
PDF file
AWArjun Wadhwa
Arjun Wadhwa
APAlexandre Perrotton
Alexandre Perrotton
MTMohamad Hassan Hassan Taherian
Mohamad Hassan Hassan Taherian
AZAbbas Zirakjou
Abbas Zirakjou
JBJaime Alberto Benavides-Guerrero
Jaime Alberto Benavides-Guerrero
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier
Humidity sensors are essential components in modern technology, spanning applications from residential appliances to the Internet of Things (IoT). However, conventional commercial sensors are typically rigid, constrained by narrow relative humidity (%RH) operating ranges, and require complex fabrication processes. In this study, we present a highly sensitive cubic silicon carbide (3C–SiC) nanoparticle-based relative humidity sensor, fabricated via serigraphic printing on to 5 mil thick flexible polyimide (Kapton®) substrate. Devices are tested across a broad humidity range of 10–90%RH at ambient temperature and their performance is evaluated in a controlled humidity chamber. The sensor exhibits a robust response of 45.2% R/R0, with a sensitivity of 5.34 Ω/%RH, an adsorption time of 18 seconds, and a desorption time of 46 seconds. Additionally, the device demonstrates low hysteresis of 6.5% at 60%RH, with excellent repeatability and stability over 3.5 hours of continuous cycling. To showcase their potential for real-world applications, the printed sensors are integrated into a commercial KN95 mask for monitoring respiration parameters, such as respiration rate. This integration highlights the potential for future exploration in human health monitoring, utilizing fully printed, low-cost sensing devices.

25 October 2023 in JMIR Biomedical Engineering
Verified
Journal Article
Open access
Fabrice VaussenatFabrice Vaussenat
Fabrice Vaussenat
ABAbhiroop Bhattacharya
Abhiroop Bhattacharya
JPJulie Payette
Julie Payette
JBJaime Alberto Benavides-Guerrero
Jaime Alberto Benavides-Guerrero
APAlexandre Perrotton
Alexandre Perrotton
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier
Background: Accurate and portable respiratory parameter measurements are critical for properly managing chronic obstructive pulmonary diseases (COPDs) such as asthma or sleep apnea, as well as controlling ventilation for patients in intensive care units, during surgical procedures, or when using a positive airway pressure device for sleep apnea. Objective: The purpose of this research is to develop a new nonprescription portable measurement device that utilizes relative humidity sensors (RHS) to accurately measure key respiratory parameters at a cost that is approximately 10 times less than the industry standard. Methods: We present the development, implementation, and assessment of a wearable respiratory measurement device using the commercial Bosch BME280 RHS. In the initial stage, the RHS was connected to the pneumotach (PNT) gold standard device via its external connector to gather breathing metrics. Data collection was facilitated using the Arduino platform with a Bluetooth Low Energy connection, and all measurements were taken in real time without any additional data processing. The device’s efficacy was tested with 7 participants (5 men and 2 women), all in good health. In the subsequent phase, we specifically focused on comparing breathing cycle and respiratory rate measurements and determining the tidal volume by calculating the region between inhalation and exhalation peaks. Each participant's data were recorded over a span of 15 minutes. After the experiment, detailed statistical analysis was conducted using ANOVA and Bland-Altman to examine the accuracy and efficiency of our wearable device compared with the traditional methods. Results: The perfused air measured with the respiratory monitor enables clinicians to evaluate the absolute value of the tidal volume during ventilation of a patient. In contrast, directly connecting our RHS device to the surgical mask facilitates continuous lung volume monitoring. The results of the 1-way ANOVA showed high P values of .68 for respiratory volume and .89 for respiratory rate, which indicate that the group averages with the PNT standard are equivalent to those with our RHS platform, within the error margins of a typical instrument. Furthermore, analysis utilizing the Bland-Altman statistical method revealed a small bias of 0.03 with limits of agreement (LoAs) of –0.25 and 0.33. The RR bias was 0.018, and the LoAs were –1.89 and 1.89. Conclusions: Based on the encouraging results, we conclude that our proposed design can be a viable, low-cost wearable medical device for pulmonary parametric measurement to prevent and predict the progression of pulmonary diseases. We believe that this will encourage the research community to investigate the application of RHS for monitoring the pulmonary health of individuals.

19 November 2025 in Flexible and Printed Electronics
Verified
Journal Article
Open access
FFFrançois-Xavier Fortier
François-Xavier Fortier
LGLuis Felipe Gerlein
Luis Felipe Gerlein
JBJaime Alberto Benavides-Guerrero
Jaime Alberto Benavides-Guerrero
AWArjun Wadhwa
Arjun Wadhwa
KSKrunal Shah
Krunal Shah
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier
Poor wettability of solder paste on printed copper (Cu) surfaces presents a significant limitation towards the reliable assembly of flexible hybrid electronic (FHE) circuits. This work addresses this challenge using a low-melting-point, bismuth-based solder on nanoparticle-based copper ink pads serigraphically printed on flexible polyimide. To improve solderability, we introduce a surface treatment involving mechanical polishing of the printed copper with sodium bicarbonate (NaHCO [t]3 ) to reduce surface porosity and remove organic residues. This treatment enhanced solder wettability by 66%, leading to superior component alignment and assembly quality. The fabricated circuits prove highly robust and withstand a 1000 h accelerated aging test at 85 ∘ C and 85% relative humidity. Cross-sectional analysis confirms formation of a 1.5 ± 0.5 μ m thick intermetallic layer, indicative of an industrial-quality FHE circuit.

10 March 2023 in JMIR Preprints
Verified
Preprint
Open access
Fabrice VaussenatFabrice Vaussenat
Fabrice Vaussenat
ABAbhiroop Bhattacharya
Abhiroop Bhattacharya
JPJulie Payette
Julie Payette
JBJaime Alberto Benavides-Guerrero
Jaime Alberto Benavides-Guerrero
APAlexandre Perrotton
Alexandre Perrotton
Sylvain CloutierSylvain Cloutier
Sylvain Cloutier
BACKGROUND Accurate and portable respiratory parameter measurements are critical for properly managing chronic obstructive pulmonary diseases (COPDs) such as asthma or sleep apnea, as well as controlling ventilation for patients in intensive care units, during surgical procedures, or when using a positive airway pressure device for sleep apnea. OBJECTIVE The purpose of this research is to develop a new nonprescription portable measurement device that utilizes relative humidity sensors (RHS) to accurately measure key respiratory parameters at a cost that is approximately 10 times less than the industry standard. METHODS We present the development, implementation, and assessment of a wearable respiratory measurement device using the commercial Bosch BME280 RHS. In the initial stage, the RHS was connected to the pneumotach (PNT) gold standard device via its external connector to gather breathing metrics. Data collection was facilitated using the Arduino platform with a Bluetooth Low Energy connection, and all measurements were taken in real time without any additional data processing. The device’s efficacy was tested with 7 participants (5 men and 2 women), all in good health. In the subsequent phase, we specifically focused on comparing breathing cycle and respiratory rate measurements and determining the tidal volume by calculating the region between inhalation and exhalation peaks. Each participant's data were recorded over a span of 15 minutes. After the experiment, detailed statistical analysis was conducted using ANOVA and Bland-Altman to examine the accuracy and efficiency of our wearable device compared with the traditional methods. RESULTS The perfused air measured with the respiratory monitor enables clinicians to evaluate the absolute value of the tidal volume during ventilation of a patient. In contrast, directly connecting our RHS device to the surgical mask facilitates continuous lung volume monitoring. The results of the 1-way ANOVA showed high P values of .68 for respiratory volume and .89 for respiratory rate, which indicate that the group averages with the PNT standard are equivalent to those with our RHS platform, within the error margins of a typical instrument. Furthermore, analysis utilizing the Bland-Altman statistical method revealed a small bias of 0.03 with limits of agreement (LoAs) of –0.25 and 0.33. The RR bias was 0.018, and the LoAs were –1.89 and 1.89. CONCLUSIONS Based on the encouraging results, we conclude that our proposed design can be a viable, low-cost wearable medical device for pulmonary parametric measurement to prevent and predict the progression of pulmonary diseases. We believe that this will encourage the research community to investigate the application of RHS for monitoring the pulmonary health of individuals.