In this paper we present an analysis of the voltage amplifier needed for double differential (DD) sEMG measurements and a novel, very simple circuit for implementing DD active electrodes. The three-input amplifier that standalone DD active electrodes require is inherently different from a differential amplifier, and general knowledge about its design is scarce in the literature. First, the figures of merit of the amplifier are defined through a decomposition of its input signal into three orthogonal modes. This analysis reveals a mode containing EMG crosstalk components that the DD electrode should reject. Then, the effect of finite input impedance is analyzed. Because there are three terminals, minimum bounds for interference rejection ratios due to electrode and input impedance unbalances with two degrees of freedom are obtained. Finally, a novel circuit design is presented, including only a quadruple operational amplifier and a few passive components. This design is nearly as simple as the branched electrode and much simpler than the three instrumentation amplifier design, while providing robust EMG crosstalk rejection and better input impedance using unity gain buffers for each electrode input. The interference rejection limits of this input stage are analyzed. An easily replicable implementation of the proposed circuit is described, together with a parameter design guideline to adjust it to specific needs. The electrode is compared with the established alternatives, and sample sEMG signals are obtained, acquired on different body locations with dry contacts, successfully rejecting interference sources.
This paper presents an improved driven right leg (DRL) circuit compensation together with a practical implementation. The proposed design allows to increase common mode voltage attenuation compared with the widely used dominant pole compensation while maintaining the same proven stability margin and design criteria, and requiring only a modification of its passive feedback network. A sample implementation of the proposed DRL was obtained estimating the values of interference model parameters for a dry electrode measurement system. A dominant pole compensated DRL with the same stability margin was also implemented in order to experimentally validate the proposed design against this established alternative. Measurements were conducted under both controlled and uncontrolled interference conditions. The proposed compensation experimentally demonstrated achieving a better reduction of power line harmonics, with a peak comparative improvement of around 18 dB at 50 Hz.
27 April 2023 in IEEE Transactions on Instrumentation and Measurement
In this work, a novel double-differential (DD) amplifier for electromyogram (EMG) measurements is presented, which requires only three electrodes, a reduced number of components, and is focused on wearable devices of reduced size. The proposed topology is dual-mode, since it can also be used as a conventional single-differential (SD) EMG amplifier. The front-end sets the measurement center node at a reference potential, and uses single-ended amplifiers to form the DD signal at the common-mode output. To be able to measure with negligible electromagnetic interference, it is necessary to achieve a sufficiently large isolation impedance. A simple circuit with discrete components was implemented that allowed validating the operation of the proposed topology. Experimental measurements were made for its characterization, and the results are: 3 dB-bandwidth from 5 Hz to 460 Hz, DD gain of 34 dB in the passband, differential mode rejection ratio greater than 40 dB in the passband, and total noise referred to the input of 2.1 μV RMS . Also, the measurement of DD signals from the amplifier was verified by comparison with an additional acquisition device. Finally, the circuit was tested inside a small wearable device to measure surface EMG (sEMG). The results of this work validate that the proposed amplifier measures DD sEMG signals with only three electrodes, and is suitable for use in portable and wearable systems. This topology requires one less electrode than usual and has an extremely simple design with a reduced number of components.
This work proposes a Double Differential (DD) amplifier topology which exploits the advantages of the current-mode approach. DD amplifiers are useful as front-ends in standalone active electrodes for superficial electromyography (sEMG) wearable applications and electroneurography (ENG) measurement devices. Front-ends for these applications need to attain low noise, high common-mode rejection ratio, and high input impedance to measure biopotential signals and can further benefit from low power operation, a small size, and an easily adaptable output. Presently published DD amplifiers are either complex in terms of a high part count, leading to higher power consumption and size, or suffer from limited interference-rejection capabilities and require further analog processing for compatibility with single-ended systems. Therefore, in this work, second-generation current conveyors have been leveraged to obtain a simple topology combining a small active-part count, a high common-mode rejection ratio, and a flexible output stage. The current-mode DD amplifier is presented and analyzed in detail to estimate its parameters and model the effects of nonidealities in the circuit. In order to validate the proposed topology, a discrete-component implementation was realized as a proof-of-concept. The results experimentally demonstrated the properties of the proposed topology and its feasibility for measuring superficial sEMG DD signals.
17 June 2022 in Journal of Medical and Biological Engineering
Objective: Fully differential topologies are well-suited for biopotential amplifiers, mainly for single-supply battery-powered circuits such as portable wearable devices where a reduced number of parts is desired. A novel fully differential biopotential amplifier is proposed with the goal of providing electrode offset rejection, bandwidth limitation, and a temporal response compliant with biomedical standards with only a single commercial quad operational amplifier (OA) integrated circuit. Methods: A novel compensation strategy was used to provide a transfer function with only one zero at the origin, which makes it easy to comply with the transient response imposed by biomedical standards. A topology with no grounded components was leveraged to obtain a common-mode rejection ratio (CMRR) ideally infinite and independent of components mismatches. Results: Design equations are presented and, as an example, an electrocardiogram (ECG) amplifier was built and tested. It features a CMRR of 102 dB at 50 Hz, 53 dB gain that supports DC input voltages up to ±300 mV when powered from a 0 V to 5 V single-supply voltage, and a cutoff frequency of less than 0.05 Hz with a first order response. Conclusion: A fully-differential biopotential front-end was designed and validated through experimental tests, demonstrating proper operation with only 4 OAs. Significance: The amplifier is intended for board-level design solutions, it can be built with off-the-shelf components that can be selected according to specific needs, such as reduced power consumption, low noise, or proper operation from a low-voltage power source.