Valentin Catacora

Dr. Valentin Catacora

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
VCValentin Catacora
Valentin Catacora
FGFederico Nicolas Guerrero
Federico Nicolas Guerrero
ESEnrique Mario Spinelli
Enrique Mario Spinelli
In this work, a novel double-differential (DD) amplifier for electromyogram (EMG) measurements is presented, which requires only three electrodes, a reduced number of components, and is focused on wearable devices of reduced size. The proposed topology is dual-mode, since it can also be used as a conventional single-differential (SD) EMG amplifier. The front-end sets the measurement center node at a reference potential, and uses single-ended amplifiers to form the DD signal at the common-mode output. To be able to measure with negligible electromagnetic interference, it is necessary to achieve a sufficiently large isolation impedance. A simple circuit with discrete components was implemented that allowed validating the operation of the proposed topology. Experimental measurements were made for its characterization, and the results are: 3 dB-bandwidth from 5 Hz to 460 Hz, DD gain of 34 dB in the passband, differential mode rejection ratio greater than 40 dB in the passband, and total noise referred to the input of 2.1 μV RMS . Also, the measurement of DD signals from the amplifier was verified by comparison with an additional acquisition device. Finally, the circuit was tested inside a small wearable device to measure surface EMG (sEMG). The results of this work validate that the proposed amplifier measures DD sEMG signals with only three electrodes, and is suitable for use in portable and wearable systems. This topology requires one less electrode than usual and has an extremely simple design with a reduced number of components.

17 June 2022 in Journal of Medical and Biological Engineering
Verified
Journal Article
Closed access
PDF file
VCValentin Catacora
Valentin Catacora
FGFederico Nicolas Guerrero
Federico Nicolas Guerrero
ESEnrique Mario Spinelli
Enrique Mario Spinelli

7 November 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ESEnrique Mario Spinelli
Enrique Mario Spinelli
FGFederico Nicolas Guerrero
Federico Nicolas Guerrero
PGPablo A. Garcia
Pablo A. Garcia
VCValentin Catacora
Valentin Catacora
MHMarcelo Haberman
Marcelo Haberman
Objective: Fully differential topologies are well-suited for biopotential amplifiers, mainly for single-supply battery-powered circuits such as portable wearable devices where a reduced number of parts is desired. A novel fully differential biopotential amplifier is proposed with the goal of providing electrode offset rejection, bandwidth limitation, and a temporal response compliant with biomedical standards with only a single commercial quad operational amplifier (OA) integrated circuit. Methods: A novel compensation strategy was used to provide a transfer function with only one zero at the origin, which makes it easy to comply with the transient response imposed by biomedical standards. A topology with no grounded components was leveraged to obtain a common-mode rejection ratio (CMRR) ideally infinite and independent of components mismatches. Results: Design equations are presented and, as an example, an electrocardiogram (ECG) amplifier was built and tested. It features a CMRR of 102 dB at 50 Hz, 53 dB gain that supports DC input voltages up to ±300 mV when powered from a 0 V to 5 V single-supply voltage, and a cutoff frequency of less than 0.05 Hz with a first order response. Conclusion: A fully-differential biopotential front-end was designed and validated through experimental tests, demonstrating proper operation with only 4 OAs. Significance: The amplifier is intended for board-level design solutions, it can be built with off-the-shelf components that can be selected according to specific needs, such as reduced power consumption, low noise, or proper operation from a low-voltage power source.

1 May 2024 in Electronics
Verified
Journal Article
Open access
PDF file
FGFederico Nicolas Guerrero
Federico Nicolas Guerrero
VCValentin Catacora
Valentin Catacora
Alfio GrassoAlfio Grasso
Alfio Grasso
Gaetano PalumboGaetano Palumbo
Gaetano Palumbo
In this work, a circuit topology for the implementation of a multi-electrode superficial electromyography (EMG) front-end is presented based on a type II current conveyor (CCII). The presented topology provides a feasible way to implement an amplifier capable of measuring several electrode locations and obtaining the signal of interest for posterior acquisition. In particular, a five-electrode normal double differential (NDD) EMG spatial filter is demonstrated. The signal modes necessary for the analysis of the circuit are derived, the respective rejection ratios are obtained, and the noise characteristic is calculated. A board-level electrode is implemented as a proof of concept, achieving a gain equal to 28 dB, a bandwidth of 17 Hz to 578 Hz, a noise voltage linked to the input of 3.7 μVrms and a common-mode rejection ratio higher than 95 dB at interference frequencies. The topology was validated after using it as an active electrode in experimental EMG measurements with an NDD dry-contact electrode in a flexible printed circuit board.

31 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
VCValentin Catacora
Valentin Catacora
ESEnrique Mario Spinelli
Enrique Mario Spinelli
Ferran ReverterFerran Reverter
Ferran Reverter
The measurement of remote capacitive sensors requires special shielding techniques to reduce the effects of the parasitic capacitance of the interconnecting cable. According to the literature, the passive-shielding technique is suggested for floating capacitive sensors (FCSs), whereas the active-shielding technique for grounded capacitive sensors (GCSs). This article focusses on the measurement of remote FCSs by analyzing the limitations of the conventional passive shielding and, then, proposing the application of the active shielding, which is typically restricted to the measurement of GCSs, to FCSs. The analysis is carried out theoretically, by simulations, and experimentally considering: a capacitive sensor of units of pF, cable capacitances from 100 pF to 1 nF that correspond to interconnecting cable lengths from 1 to 10 m, three commercial operational amplifiers (OAs) with different values of open-loop gain, and two operating frequencies (10 and 100 kHz). According to the results reported herein, the passive-shielding technique has significant limitations when the cable is long and the operating frequency is high. For example, at 10 m and using the best OA in terms of open-loop gain, the cable introduces an error (relative to the full scale) of around 2 % at 10 kHz, but 60 % at 100 kHz. The application of the active-shielding technique significantly reduces such errors, although an additional OA is required to drive the cable shield. For instance, under the same conditions indicated before, the resulting error is around 0.01 % at 10 kHz and 1 % at 100 kHz. Therefore, for scenarios with long interconnecting cables requiring high operating frequencies, the application of active shielding seems to be really necessary to avoid large measuring errors.

3 January 2022 in Research Square
Verified
Preprint
Open access
PDF file
VCValentin Catacora
Valentin Catacora
FGFederico Guerrero
Federico Guerrero
ESEnrique Spinelli
Enrique Spinelli
Purpose: In this work, it is shown that small, battery-powered wireless devices are so robust against electromagnetic interference that single-ended amplifiers can become a viable alternative for biopotential measurements, even without a Driven Right Leg (DRL) circuit. Methods: A power line interference analysis is presented for this case showing that this simple circuitry solution is feasible, and presenting the constraints under which it is so: small-size devices with dimensions less than 40 mm × 20 mm. Results: A functional prototype of a two-electrode wireless acquisition system was implemented using a single-ended amplifier. This allowed validating the power-line interference model with experimental results, including the acquisition of electromyographic (EMG) signals. The prototype, built with a size fulfilling the proposed guidelines, presented power-line interference voltages below 1.2 µVPP when working in an office environment. Conclusion: It can be concluded that a single-ended biopotential amplifier can be used if a sufficiently large isolation impedance is achieved with small-size wireless devices. This approach allows measurements with only two electrodes, a very simple front-end design, and a reduced number of components.