Marcelo Haberman

Dr. Marcelo Haberman

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2019 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MHMarcelo Haberman
Marcelo Haberman
ESEnrique M. Spinelli
Enrique M. Spinelli
This work presents the design and implementation details of a complete non-contact (NC) voltage acquisition system, which allows the measurement of power-line voltage waveforms without galvanic contact. The system is composed by a novel capacitive probe, an analog front-end, and a microcontroller-based digital signal processing stage. A deep experimental characterization of the non-contact measurement system was performed. The tests reported a high linearity (maximum non-linearity of ±0.2%), a low input-referred noise (11 mVRMS), and a low frequency response distortion. Measurements of ±330 V triangular waveform signals were performed with maximum instantaneous errors below ±1.5V. The power-line voltage (220 VRMS @ 50 Hz) was acquired without galvanic contact with an instantaneous error lower than ±3 V, whereas the mean error on RMS voltage measurements was 0.32% and the maximum 0.7%. A two-days continuous measurement of power line voltage was accomplished for testing system’s stability, resulting in negligible accuracy variations.

13 April 2012 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
MHMarcelo Haberman
Marcelo Haberman
ESEnrique Mario Spinelli
Enrique Mario Spinelli
Single ended (SE) amplifiers allow implementing biopotential front-ends with a reduced number of parts, being well suited for preamplified electrodes or compact EEG headboxes. On the other hand, given that each channel has independent gain; mismatching between these gains results in poor common-mode rejection ratios (CMRRs) (about 30 dB considering 1% tolerance components). This work proposes a scheme for multichannel EEG acquisition systems based on SE amplifiers and a novel digital driven right leg (DDRL) circuit, which overcome the poor CMRR of the front-end stage providing a high common mode reduction at power line frequency (up to 80 dB). A functional prototype was built and tested showing the feasibility of the proposed technique. It provided EEG records with negligible power line interference, even in very aggressive EMI environments.

1 February 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MHMarcelo Haberman
Marcelo Haberman
ESEnrique Mario Spinelli
Enrique Mario Spinelli
Ferran ReverterFerran Reverter
Ferran Reverter
This article presents a novel front-end circuit for remote grounded capacitive sensors. The circuit is insensitive to amplifier input capacitance and stray interconnecting-cable capacitances. It does not rely on neutralization or compensation techniques that require manual adjustments and high-accuracy reference components. The proposed solution reduces the circuit input capacitance below a few femptofarads using a simple but properly shielded custom transformer. In addition, the circuit keeps a nonlinearity error below 0.01% when measuring capacitances of units or tens of picofarad, even with up to 12-m interconnecting cables.

12 September 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MHMarcelo Haberman
Marcelo Haberman
ESEnrique Mario Spinelli
Enrique Mario Spinelli
Ferran ReverterFerran Reverter
Ferran Reverter
In this article, a novel supply-voltage driving (SVDR) scheme for capacitive sensor front-ends is proposed to eliminate the parasitic capacitance effects. The suggested circuit is intended for remote sensors (and, hence, connected to the circuit through a shielded cable) with one electrode grounded and of low capacitance (in the 0–10-pF range). The effects of the parasitic capacitance of the cable are avoided using the active-shielding technique, whereas those of the amplifier input through a smart driving of the reference node of the amplifier supply voltage. Thanks to these techniques, the input–output characteristic shows, without applying any adjustment and/or calibration, an offset error lower than 3 fF. The nonlinearity error (NLE) is in the order of 0.01% of the full-scale span (FSS), which corresponds to 1 fF. Different operational amplifiers (OAs) and different lengths (up to 15 m) of the interconnecting cable are experimentally tested to demonstrate the feasibility of the circuit. In comparison with similar circuits recently suggested in the literature, the proposed circuit does not require any bulky component, such as a transformer, and consequently, it is a lower-cost solution and suitable to be integrated.

1 August 2010
Verified
Conference Paper
Closed access
MHMarcelo Haberman
Marcelo Haberman
ESEnrique Spinelli
Enrique Spinelli
A novel scheme and a digital approach to the Driven Right Leg Circuit (DRL) are presented. It presents an ultra high common mode (CM) reduction of power line interference (higher than 80dB) without endangering stability. This improves by 40-50dB the CM reduction provided by a classical analog DRL, retaining the same stability criterion. The improvement comes from the inclusion of a high Q resonator in parallel with the common mode amplifier. It provides a large gain at power line frequency (50/60 Hz) whereas it does not significantly affect the open loop gain for high frequencies. The proposed scheme can be thought as an analog circuit, but the accuracy required, mainly in the resonator frequency response, leads to a digital implementation. In this way, component ageing and thermal fluctuation problems are avoided, as well as the need for manual adjusting. A prototype of the proposed DRL circuit was built and tested in laboratory conditions showing an open-loop gain of 74dB at 50Hz. It was also tested by acquiring real EEG signals.

7 November 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ESEnrique Mario Spinelli
Enrique Mario Spinelli
FGFederico Nicolas Guerrero
Federico Nicolas Guerrero
PGPablo A. Garcia
Pablo A. Garcia
VCValentin Catacora
Valentin Catacora
MHMarcelo Haberman
Marcelo Haberman
Objective: Fully differential topologies are well-suited for biopotential amplifiers, mainly for single-supply battery-powered circuits such as portable wearable devices where a reduced number of parts is desired. A novel fully differential biopotential amplifier is proposed with the goal of providing electrode offset rejection, bandwidth limitation, and a temporal response compliant with biomedical standards with only a single commercial quad operational amplifier (OA) integrated circuit. Methods: A novel compensation strategy was used to provide a transfer function with only one zero at the origin, which makes it easy to comply with the transient response imposed by biomedical standards. A topology with no grounded components was leveraged to obtain a common-mode rejection ratio (CMRR) ideally infinite and independent of components mismatches. Results: Design equations are presented and, as an example, an electrocardiogram (ECG) amplifier was built and tested. It features a CMRR of 102 dB at 50 Hz, 53 dB gain that supports DC input voltages up to ±300 mV when powered from a 0 V to 5 V single-supply voltage, and a cutoff frequency of less than 0.05 Hz with a first order response. Conclusion: A fully-differential biopotential front-end was designed and validated through experimental tests, demonstrating proper operation with only 4 OAs. Significance: The amplifier is intended for board-level design solutions, it can be built with off-the-shelf components that can be selected according to specific needs, such as reduced power consumption, low noise, or proper operation from a low-voltage power source.