Jan Leffler

Mr. Jan Leffler

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 April 2025 in Energies
Verified
Journal Article
Open access
PDF file
Pavel TrnkaPavel Trnka
Pavel Trnka
Jaroslav HornakJaroslav Hornak
Jaroslav Hornak
MTMagdalena Trnkova
Magdalena Trnkova
Ondřej MichalOndřej Michal
Ondřej Michal
ZMZdislava Mokrá
Zdislava Mokrá
ZFZdeněk Frána
Zdeněk Frána
The introduction of a new insulating oil or, for instance, a new type of insulation or sealing into a transformer necessitates tests for material compatibility. Compatibility tests of liquids with the structural internal materials of transformers are conducted to prevent undesired interactions between insulating fluids and the formation of products that could lead to the generation of undesirable ions, sediments, or chemical compounds that result in a reduction in the dielectric property performance of the fluid. This includes chemical reactions (hydrolysis, hydrogenation, oxidation, formation of sulfates or sulfides, etc.) and degradation, the formation of conductive suspensions, the generation of undesirable condensation, and alterations in other fluid properties, such as interfacial tension between oil and water, viscosity, flashpoint, etc. Changes must also not occur in the strength and hardness of gasket material, which could result in undesirable fluid leakage. This paper describes the novel methodology and results of several proposed tests, including the impact on oil viscosity, material hardness, FT-IR analysis of oils, partial discharges in different oils, dielectric properties, and more, conducted during compatibility and aging tests at 120 °C and 140 °C performed on materials used in particular distribution transformers being prepared for natural ester use. The results show notable differences in the behavior of insulating fluids and aged submerged materials. While mineral oils exhibit lower dissipation factors compared to natural esters, the latter demonstrate slower and less severe hardening effects on gaskets during high-temperature aging (e.g., Shore 35.25 in mineral oil vs. 21–22.5 in natural esters). The tensile strength of the tested cable ties decreased significantly (from 260 to approx. 60 N) in mineral oil but increased in natural ester (320 N/120 °C exposition). This study also highlights a novel insight into partial discharge mechanisms, where differences in viscosity, conductivity phenomena, and dielectric constants result in presented differences in inception voltages and prebreakdown activity.

16 July 2024 in Polymers
Verified
Journal Article
Open access
PDF file
JLJan Leffler
Jan Leffler
JKJan Kaska
Jan Kaska
Petr KadlecPetr Kadlec
Petr Kadlec
PPPavel Prosr
Pavel Prosr
VŠVáclav Šmídl
Václav Šmídl
Pavel TrnkaPavel Trnka
Pavel Trnka
The degradation of electrical insulating materials has been a subject of interest for decades as they are commonly applied in many fields of electrical engineering. Suitably modeling such a process is important since the known and well-described degradation process reveals the effect of ambient conditions, and this allows us to possibly estimate a material’s remaining useful life. However, not many studies are dealing with the effect of the hygrothermal degradation of impregnating mono-component epoxy resins in the context of electrical engineering. Therefore, this study deals with this issue and discusses both the dielectric response (based on the measurement of relative permittivity, dissipation factor, and dielectric strength) and the mechanical response (based on measurements of tensile strength and Shore D hardness) to a hygrothermal degradation experiment. In addition, the results of thermal analyses are presented for the evaluation of the pristine specimen manufacturing process and possible post-curing processes. Furthermore, this study presents several methodologies for modeling the degradation process, including a novel methodology in this area based on Bayesian experimental design. As an outcome, mechanical parameters are proven to be specific in terms of the actual condition of the material and the Bayesian enhanced degradation model seems to be superior to the conventional evaluation methods in this particular study.

18 May 2025
Verified
Conference Paper
Closed access
Pavel TrnkaPavel Trnka
Pavel Trnka
Jaroslav HornakJaroslav Hornak
Jaroslav Hornak
Ondřej MichalOndřej Michal
Ondřej Michal
ZMZdislava Mokrá
Zdislava Mokrá
SHStefan Hardon
Stefan Hardon
TTTetjana Tomaskova
Tetjana Tomaskova
The comparative study of the aging processes of cellulose paper and Nomex® paper in biodegradable insulating fluids in various condition is of importance to the electrical engineering field, particularly in the development and maintenance of sustainable high-voltage insulation systems. This research investigates the aging behavior of these insulation materials when immersed in eco-friendly, biodegradable fluids, aiming to evaluate their longevity and performance under various operational stress. Electrical insulating systems based on synthetic, natural and mineral oil are compared when solid part is created by cellulose and aramid paper.

16 February 2026 in TechRxiv
Verified
Preprint
Open access
JLJan Leffler
Jan Leffler
PTPavel Trnka
Pavel Trnka
There are various types of electrical rotating machines and transformers within various classes of power range and duty cycles applied within the industry. It is a matter of fact that every machine can eventually fail and both damage and subsequent immediate and additional losses might occur. Besides, the aging management approach might be implemented to utilize an asset portfolio in an organized manner. Therefore, it is necessary to analyze failure modes and evaluate failure rates and their distribution over certain electrical machine types and their subsystems to better understand the operation conditions and limits. Based on this information, it is also important to identify suitable subsystems and locations for monitoring and testing. This goes hand in hand with a better assessment of an asset's condition and potential risks which is part of the asset management concept. This paper presents a comprehensive failure analysis based on publicly available data, summarizes, categorizes, and compares results obtained from various studies for various electrical machine types, and offers a broad context. It identifies important machines’ subsystems in terms of failure modes and presents a solid overview of failure rates. The cause and rate of failures and affected subsystems are also discussed in the context of maintenance. Furthermore, this paper suggests general possible procedures for failure elimination or mitigation of the risks, through described maintenance strategies, condition monitoring instrumentation, and assessment approaches including prognostics.