Mohammed Salman j. Almalki

Dr. Mohammed Salman j. Almalki

orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DLDr.Honey Lunkad
Dr.Honey Lunkad
Mohammed SayedMohammed Sayed
Mohammed Sayed
AAAbdullah Essa Alhazmi
Abdullah Essa Alhazmi
BABandar Alwadani
Bandar Alwadani
ASAmeen Marwei Shafei
Ameen Marwei Shafei
SJSaurabh Jain
Saurabh Jain
A well-made provisional fixed prosthesis must present as a preview of the future prosthesis and may also augment the health of the abutments and periodontium. Provisional restorations have been prepared chairside with polymethyl methacrylate (PMMA) since time immemorial. CAD/CAM additive and subtractive technologies have revolutionized the fabrication of interim restorations in dental clinics. The current literature lacks substantial data about retention of provisional crowns manufactured using Computer-Aided Design/Computer-Aided Manufacturing (CAD/CAM) additive and subtractive techniques with various temporary cements. This in vitro study aims to assess and compare the retention of temporary/provisional anterior crowns based on the combined effect of different digital manufacturing techniques, preparation tapers, and the temporary cements used for cementation. Two maxillary right central incisor typodont teeth were prepared to receive all-ceramic crowns, one with a 10-degree taper and the other with a 20-degree taper. Forty 3D-printed working models with the 10° taper and forty working models with the 20° taper were prepared to receive the temporary crowns. Forty temporary crowns were 3D-printed and forty crowns were milled (20 from each taper group). Kerr Temp-Bond NE conventional cement and Kerr Temp-Bond clear cement were used for cementation in the two groups. The number of samples per test group was 10. All samples were thermocycled and subjected to a universal testing machine to measure the pull-off force until retention loss (N) under tension with a crosshead speed of 5 mm/min. The pull-off force was highest for group 8, i.e., 3D-printed crowns with a 20° taper and cemented with Kerr Temp-Bond clear cement, followed by groups 6, 7, 4, 5, 3, and 2. Group 1, i.e., milled crowns with 10° taper cemented with Kerr Temp-Bond NE conventional cement, exhibited the lowest pull-off retentive force. The clinical selection of long-term provisional crowns fabricated using 3D-printing technology, prepared with 10° or 20° tapers, and cemented with clear cement, is the most favorable in terms of the retention of provisional crowns. 3D-printed provisional crowns can be used as an alternative to conventional and CAD/CAM-milled crowns for long-term provisionalization.

23 December 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
SASaeed M. Alqahtani
Saeed M. Alqahtani
MAMohammed Salman j. Almalki
Mohammed Salman j. Almalki
MAMai Almarzouki
Mai Almarzouki
SASaad AlResayes
Saad AlResayes
NHNisreen Nabiel Hassan
Nisreen Nabiel Hassan
Mohammed SayedMohammed Sayed
Mohammed Sayed
Background: This study aims to perform a review by selecting, analyzing, and evaluating articles that discuss the accuracy of intraoral scanners (IOSs) in recording post space compared to conventional impression-making techniques. Methods: The review question framed using the PITR framework (participant, index test, targeted condition, and reference standard) is as follows: What is the dimensional accuracy (T) of impressions made using intraoral scanners (I) for post space (P) compared to impressions made using conventional techniques and digitalized using extraoral scanners (R)? Four electronic databases were searched using pre-set keywords. The guidelines and strategies recommended by PRISMA formed the basis for planning, executing, and documenting this systematic review. QUADAS-2 was used to critically analyze the quality of all the selected articles. Results: After excluding ineligible articles, the end synthesis has nine studies (n = 9) for qualitative analysis. All nine evaluated studies were found to be at risk of bias, with high or unclear risk in one or more domains. Three out of nine evaluated studies had unclear concerns regarding the applicability, and the remaining six had low concerns. In all the included studies, the IOSs were reported to have deviations in accuracy compared to the conventional techniques for making digital impressions of post space. Conclusions: The accuracy of IOSs was found to be inversely proportional to the length of post space and directly proportional to the diameter of post space. IOSs, when used adequately in short post spaces, can be an alternative to conventional impression-making for making custom posts and cores.