Tobacco consumption in its different forms can affect the optical and surface properties of dental materials that are used in the oral cavity. Thus, the present study was conducted to evaluate the effects of two commercially available smokeless tobacco products on the color stability and surface roughness of denture base resins that were fabricated using three different techniques (CAD/CAM milling, 3D printing, and conventional heat polymerization). A total of 126 denture base resin specimens were fabricated using the three different manufacturing techniques (n = 42 each). Specimens from each group were further subdivided into three subgroups (n = 14 each) and immersed in three different immersion media (a khaini suspension, a tabbaq suspension, and artificial saliva). The differences in color and surface roughness were assessed according to data that were collected and statistically analyzed using SPSS version 24.0. The tabbaq smokeless tobacco was found to cause greatest changes in color and surface roughness; the effect was observed to be highest in the 3D-printed specimens followed by the conventional heat-polymerized and CAD/CAM milled specimens. The mean changes in color and surface roughness were the highest for the tabbaq smokeless tobacco followed by the khaini smokeless tobacco and the artificial saliva. Statistically significant (p-value < 0.05) differences were observed among all techniques and suspensions. We concluded that the mean changes in color and surface roughness were significantly higher for the 3D-printed dentures compared to the conventional heat-polymerized and CAD/CAM-milled dentures. Thus, the results of the present study strengthened the concept that tobacco in any form can lead to changes in the color and surface roughness of denture base materials.
The aim of this study was to assess the shear bond strength of 3D-printed and milled provisional restorations using various resin materials and surface finishes. There were 160 preliminary samples in all, and they were split into two groups: the milled group and the 3D-printed group. Based on the resin used for repair (composite or polymethylmethacrylate (PMMA)) and the type of surface treatment utilized (chemical or mechanical), each group was further divided into subgroups. The specimens were subjected to thermocycling from 5 °C to 55 °C for up to 5000 thermal cycles with a dwell time of 30 s. The mechanical qualities of the repaired material underwent testing for shear bond strength (SBS). To identify the significant differences between the groups and subgroups, a statistical analysis was carried out. Three-way ANOVA was used to analyze the effects of each independent component (the material and the bonding condition), as well as the interaction between the independent factors on shear bond strength. Tukey multiple post-hoc tests were used to compare the mean results for each material under various bonding circumstances. The shear bond strengths of the various groups and subgroups differed significantly (p < 0.05). When compared to the milled group, the 3D-printed group had a much greater mean shear bond strength. When compared to PMMA repair, the composite resin material showed a noticeably greater shear bond strength. In terms of surface treatments, the samples with mechanical and chemical surface treatments had stronger shear bonds than those that had not received any. The results of this study demonstrate the effect of the fabrication method, resin type, and surface treatment on the shear bond strength of restored provisional restorations. Particularly when made using composite material and given surface treatments, 3D-printed provisional restorations showed exceptional mechanical qualities. These results can help dentists choose the best fabrication methods, resin materials, and surface treatments through which to increase the durability and bond strength of temporary prosthesis.
Purpose: This study aimed to investigate the effect of chlorhexidine (CHX) cavity disinfectant on interfacial microleakage and micro-tensile bond strength (μTBS) of a universal adhesive bonded to dentin in both self-etch (SE) and etch-and-rinse (ER) modes. Methods: Class I cavities were prepared in the coronal dentin of extracted human teeth and assigned to two etching modes (SE or ER), then subdivided by disinfection with or without CHX (n = 5). Cavities were restored using Single Bond Universal Adhesive and Filtek Z350 XT composite. After 10,000 thermal cycles, interfacial microleakage was assessed on serial B-scans obtained for each specimen using cross-polarization optical coherence tomography. For μTBS testing, resin composite was bonded to dentin discs, sectioned into beams, and subjected to tensile load until failure using a universal testing machine. Failure modes in fractured beams were analyzed under a stereomicroscope and categorized as adhesive, cohesive, or mixed. ANOVA with Bonferroni post-hoc at a significance level of 0.05 was used to compare the groups. Results: Microleakage was not significantly influenced by the etching mode or CHX disinfection (p-value = 0.068). For μTBS, the ER group exhibited the highest values, and CHX disinfection did not significantly alter these results (p-value = 1.000). In contrast, the SE-CHX group displayed significantly lower μTBS than the ER, ER-CHX, and SE groups (p-values of <0.001, <0.001 and 0.012, respectively). ER mode primarily resulted in adhesive failures, regardless of CHX. SE group exhibited both adhesive and cohesive failures, while SE-CHX mostly showed adhesive failures. Conclusion: The use of CHX disinfectant influences the bonding performance of universal adhesive differently depending on the application mode. Specifically, in the SE mode, CHX adversely affects bond strength to dentin. This suggests that when using universal adhesives in SE mode, clinicians should carefully consider the use of CHX disinfectants, as they may interfere with the adhesive’s effectiveness.
This study determined the influence of surface treatment and protracted ageing on the shear bond strength (SBS) of orthodontic brackets bonded to CADCAM (milled) and 3D-printed polymethylmethacrylate (PMMA) provisional crowns (PCs). Eighty disc-shaped specimens [forty milled (CopraTemp WhitePeaks) [group (Gp) M] and forty printed (Asiga DentaTooth) (Gp P)] were divided into eight subgroups (Gp) based on surface treatment [no treatment (control) (Gp MC and Gp PC), coarse diamond (Gp MCD and Gp PCD), fine diamond (Gp MFD, and GP PFD) and sandblast (Gp MSB and Gp PSB)]. Orthodontic brackets were bonded (Assure Plus, Transbond XT), thermocycled (2200 cycles), and tested for SBS and failure (Adhesive Remnant Index) (ARI). Statistical tests included analysis of variance (ANOVA); Kruskal–Wallis (ARI ranks); and post hoc (Tukey, Dunn, and Bonferroni) for determining group differences at predetermined probability p-values less than 0.05. SBS was significantly increased in Gp MSB (15.51 Mpa) and Gp PSB (14.11 Mpa), while the coarse diamond subgroups yielded the lowest mean SBS values [Gp MCD (11.28 Mpa) and Gp PCD (11.62 Mpa)]. The SBS of subgroups MFD, MSB, PCD, and PSB showed significant differences from those of their respective controls (Gp MC and Gp PC). Low ARI scores were observed in Gp MC (0.40) and Gp MSB (0.80), while higher scores were observed in Gp PCD (2.10). Both milled and printed PCs fulfil the clinical criteria of the minimum SBS for orthodontic brackets for long-term use. However, milled PC has better SBS and low ARI scores, which make it more clinically feasible for orthodontic treatments.
Background: This study aims to perform a review by selecting, analyzing, and evaluating articles that discuss the accuracy of intraoral scanners (IOSs) in recording post space compared to conventional impression-making techniques. Methods: The review question framed using the PITR framework (participant, index test, targeted condition, and reference standard) is as follows: What is the dimensional accuracy (T) of impressions made using intraoral scanners (I) for post space (P) compared to impressions made using conventional techniques and digitalized using extraoral scanners (R)? Four electronic databases were searched using pre-set keywords. The guidelines and strategies recommended by PRISMA formed the basis for planning, executing, and documenting this systematic review. QUADAS-2 was used to critically analyze the quality of all the selected articles. Results: After excluding ineligible articles, the end synthesis has nine studies (n = 9) for qualitative analysis. All nine evaluated studies were found to be at risk of bias, with high or unclear risk in one or more domains. Three out of nine evaluated studies had unclear concerns regarding the applicability, and the remaining six had low concerns. In all the included studies, the IOSs were reported to have deviations in accuracy compared to the conventional techniques for making digital impressions of post space. Conclusions: The accuracy of IOSs was found to be inversely proportional to the length of post space and directly proportional to the diameter of post space. IOSs, when used adequately in short post spaces, can be an alternative to conventional impression-making for making custom posts and cores.
Introduction: The objective of the study is to assess the level of light-curing unit (LCU) knowledge and clinical practice held by dental professionals working in the Western Region of Saudi Arabia. Methods: The study used a cross-sectional design with an online questionnaire distributed among dental practitioners in the Western Region of Saudi Arabia (n=379). The questionnaire included knowledge of LCUs and material science, clinical practice related to LCUs, maintenance of LCUs, and the level of satisfaction. Descriptive statistics and Pearson's chi-squared test were used for statistical analysis. Results: Low level of knowledge was reported among participants with significant associations among different specialties, education level, and years of experience (p<0.05). Most participants reported acceptable clinical practice but below-standard maintenance and control of LCUs. Discussion: Knowledge of LCUs was generally insufficient, with higher levels observed among specialists and those with advanced qualifications. However, the findings may be influenced by the sample's limited geographic diversity and predominance of less experienced general practitioners. Conclusion: Within the limitations of the study, dental practitioners in the Western Region of Saudi Arabia demonstrated inadequate knowledge and improper maintenance of LCUs despite their acceptable clinical practice of LCUs. This could impact the longevity of the delivered restorations.