The present article describes the diagnostics of a compressor that is compressing a mixture of H2 and N2 on the basis of the results that were obtained by operational measurements of the flow rates and temperatures at selected compressor sites, as well as of the acoustic pressure levels during the full loading thereof. The obtained data were subsequently used to determine the limit conditions of the compressor operations in terms of the cooling capacity. A thermodynamic analysis of the compression of the H2/N2 gas mixture was carried out with subsequent heat and energy flow calculation and the determination of the minimum cooling water flow rate that is required to ensure the continuous compressor operations.
This article presents a description of a novel method for the identification of a decrease in the temperature of a liquid medium transported by railroad tank cars. No exact analytical solution exists for this phenomenon; therefore, the authors of this article have prepared a mathematical expression for the cooling process of the transported fluid by applying a dimensional analysis, which facilitated the identification of the dimensionless criteria using the relevant dimensional parameters. A functional dependence between the criteria can be identified through a physical or numerical experiment. In this case, a database of the results from a detailed numerical model was used; however, its disadvantage is that the calculation takes much longer than in a simpler similarity model. The output of the similarity model was a function of the average temperature of the fluid at a time applicable to various alternatives in the geometrical, physical, and boundary conditions. The standard deviation of the difference between the temperatures predicted by the similarity model and those calculated by the numerical simulation Tmod − Tsim represented 4.8% relative to the simulated fluid temperature.
This article describes an innovative method for the determination of heat flow (specific heat loss; linear heat flow density) from a one-metre length of a twin pipe directly-buried heat network. Such heat losses are currently described by applying analytical procedures based on the heat transfer theory. It is rather complicated to accurately express the heat loss using such procedures, due to the necessity to determine the individual values of thermal resistance. A simpler method to express heat loss is the balance method, as it requires measuring a temperature gradient Δt between the starting point of the heat network and the end point of the heat collection. A suitable measuring device must provide high-accuracy measurements of the temperature. In the case of very well-insulated distribution pipelines and short pipes, the temperature measurements must be accurate to the hundredths of a degree Celsius. It is impossible to install such devices as fixed equipment on every heat distribution network, due to such networks measuring many kilometres and the cost of the appropriate measuring technology. For the aforesaid reasons, the authors created a mathematical model for specific heat losses based on dimensional analysis. This method facilitates the identification of dimensionless criteria based on the relevant dimensional quantities. Functional correlations between the identified criteria may be identified on the basis of the results of physical or numerical experiments. In this study, a database of the results obtained from physical experiments conducted on two heat networks was used. The output of the similarity model was a function describing the heat flow from a one-meter pipe length that was applicable to various alternatives in relation to the geometrical, physical and boundary conditions. The standard deviation of a difference in the heat losses identified by applying the balance method and using the proposed criterial equation for a twin pipe directly-buried pre-insulated heat network was 0.515 W·m−1.
This article presents an analysis of three different approaches to the identification of the thickness of the fouling layer inside the pipes of natural gas (NG) coolers. At present, there is no existing simple analytical procedure for the identification of the fouling layer thickness. The authors of this article describe in detail the balance method, which required the use of a large number of physical parameters, changes in their sizes depending on the output temperature of the gas, the temperature of the cooling air, the air quantity, as well as the physical properties of both media. The computational model was robust, and its disadvantage was the iterative computation. The second analysed method was a dimensional analysis. It was applied using the Buckingham’s theorem to express the individual similarity criteria. In this method, 10 simplexes and two complexes were created. The fouling layer thickness, expressed using a derived criterial equation, exhibited real results. The third analysed method was based on analysing selected physical parameters with the use of a multiple regression analysis in MinitabX 18 software. The analysis showed that the fouling layer thickness depended on fewer parameters than the number of parameters assumed in the dimensional analysis or the balance method. The standard deviation that was identified in the multiple linear regression for a double crossflow cooler was 0.0667 and the value of reliability (the coefficient of determination of the multiple linear regression) R2 was 0.9985.
This paper deals with the comparison of an analytical solution of the temperature field of a steam boiler pipe membrane wall using a numerical method calculation in the COSMOS/M programme. The result analysis showed that analytical calculating...