Romana Dobáková

Dr. Romana Dobáková

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MLMarián Lázár
Marián Lázár
IMIvan Mihalik
Ivan Mihalik
TBTomáš Brestovič
Tomáš Brestovič
NJNatália Jasminská
Natália Jasminská
LTLukáš Tóth
Lukáš Tóth
ŠHŠimon Hudák
Šimon Hudák
The utilisation of hydrogen in ships has important potential in terms of achieving the decarbonisation of waterway transport, which produces approximately 3% of the world’s total emissions. However, the utilisation of hydrogen drives in maritime and inland shipping is conditioned by the efficient and safe storage of hydrogen as an energy carrier on ship decks. Regardless of the type, the constructional design and the purpose of the aforesaid vessels, the preferred method for hydrogen storage on ships is currently high-pressure storage, with an operating pressure of the fuel storage tanks amounting to tens of MPa. Alternative methods for hydrogen storage include storing the hydrogen in its liquid form, or in hydrides as adsorbed hydrogen and reformed fuels. In the present article, a method for hydrogen storage in metal hydrides is discussed, particularly in a certified low-pressure metal hydride storage tank—the MNTZV-159. The article also analyses the 2D heat conduction in a transversal cross-section of the MNTZV-159 storage tank, for the purpose of creating a final design of the shape of a heat exchanger (intensifier) that will help to shorten the total time of hydrogen absorption into the alloy, i.e., the filling process. Based on the performed 3D calculations for heat conduction, the optimisation and implementation of the intensifier into the internal volume of a metal hydride alloy will increase the performance efficiency of the shell heat exchanger of the MNTZV-159 storage tank. The optimised design increased the cooling power by 46.1%, which shortened the refuelling time by 41% to 2351 s. During that time, the cooling system, which comprised the newly designed internal heat transfer intensifier, was capable of eliminating the total heat from the surface of the storage tank, thus preventing a pressure increase above the allowable value of 30 bar.

1 December 2016 in Measurement
Verified
Journal Article
Closed access
MČMária Čarnogurská
Mária Čarnogurská
MPMiroslav Příhoda
Miroslav Příhoda
MPMichal Puškár
Michal Puškár
MFMichal Fabian
Michal Fabian
RDRomana Dobáková
Romana Dobáková
MKMichal Kubík
Michal Kubík

17 April 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
TBTomáš Brestovič
Tomáš Brestovič
MČMária Čarnogurská
Mária Čarnogurská
MPMiroslav Příhoda
Miroslav Příhoda
PLPeter Lukáč
Peter Lukáč
MLMarián Lázár
Marián Lázár
RDRomana Dobáková
Romana Dobáková
The present article describes the diagnostics of a compressor that is compressing a mixture of H2 and N2 on the basis of the results that were obtained by operational measurements of the flow rates and temperatures at selected compressor sites, as well as of the acoustic pressure levels during the full loading thereof. The obtained data were subsequently used to determine the limit conditions of the compressor operations in terms of the cooling capacity. A thermodynamic analysis of the compression of the H2/N2 gas mixture was carried out with subsequent heat and energy flow calculation and the determination of the minimum cooling water flow rate that is required to ensure the continuous compressor operations.

29 January 2021 in Processes
Verified
Journal Article
Open access
PDF file
TBTomáš Brestovič
Tomáš Brestovič
MLMarián Lázár
Marián Lázár
NJNatália Jasminská
Natália Jasminská
JZJozef Zivcak
Jozef Zivcak
LTLukáš Tóth
Lukáš Tóth
ĽBĽubomíra Bednárová
Ľubomíra Bednárová
The present article discusses the potential for hydrogen separation using a metal hydride separator, which facilitates the generation of hydrogen contained in syngas following the thermal recovery of wastes. The article provides a detailed description of the separator heat balance using analytical calculations and optimised calculations, and by applying numerical methods. The proposed concept of a separator intended for hydrogen separation from syngas offers a solution to a problem associated with the use of metal hydride alloy powders; in particular, their low thermal conductivity. In order to eliminate big temperature differences in the alloy, a heat transfer intensifier was implemented in the metal hydride alloy volume; the intensifier was made of metal and exhibited high thermal conductivity. For the purpose of comparing the thermal fields, the first stage comprised the creation of a numerical simulation of hydrogen absorption without the use of an intensifier. Subsequently, three different geometries were created for an intensifier intended to remove heat from the metal hydride alloy powder towards the separator cover, and the effects of these three geometries were analysed. The implementation of heat transfer intensifiers into the metal hydride alloy powder improved the heat removal by as much as 43.9% and increased the thermal field homogeneity by 77%. A result of the heat removal optimisation was an increase in the hydrogen absorption kinetics and the efficiency of the separator operation.

1 January 2020 in Fire Safety Journal
Verified
Journal Article
Closed access
TBTomáš Brestovič
Tomáš Brestovič
MPMichal Puškár
Michal Puškár
NJNatália Jasminská
Natália Jasminská
MLMarián Lázár
Marián Lázár
RDRomana Dobáková
Romana Dobáková
LTLukáš Tóth
Lukáš Tóth

30 September 2017 in International Journal of Engineering Research & Science
Verified
Journal Article
Closed access
NJNatália Jasminská
Natália Jasminská
TBTomáš Brestovič
Tomáš Brestovič
LBLubica Bendarova
Lubica Bendarova
MLMarián Lázár
Marián Lázár
RDRomana Dobáková
Romana Dobáková