Jean-Marie Aerts

Prof. Jean-Marie Aerts

KU Leuven, Division Animal and Human Health Engineering, 3000 Leuven, Belgium
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
JBJoren Buekers
Joren Buekers
JTJan Theunis
Jan Theunis
Patrick De BoeverPatrick De Boever
Patrick De Boever
AVAnouk Vaes
Anouk Vaes
MKMaud Koopman
Maud Koopman
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts
Background: Chronic obstructive pulmonary disease (COPD) patients can suffer from low blood oxygen concentrations. Peripheral blood oxygen saturation (SpO2), as assessed by pulse oximetry, is commonly measured during the day using a spot check, or continuously during one or two nights to estimate nocturnal desaturation. Sampling at this frequency may overlook natural fluctuations in SpO2. Objective: This study used wearable finger pulse oximeters to continuously measure SpO2 during daily home routines of COPD patients and assess natural SpO2 fluctuations. Methods: A total of 20 COPD patients wore a WristOx2 pulse oximeter for 1 week to collect continuous SpO2 measurements. A SenseWear Armband simultaneously collected actigraphy measurements to provide contextual information. SpO2 time series were preprocessed and data quality was assessed afterward. Mean SpO2, SpO2 SD, and cumulative time spent with SpO2 below 90% (CT90) were calculated for every (1) day, (2) day in rest, and (3) night to assess SpO2 fluctuations. Results: A high percentage of valid SpO2 data (daytime: 93.27%; nocturnal: 99.31%) could be obtained during a 7-day monitoring period, except during moderate-to-vigorous physical activity (MVPA) (67.86%). Mean nocturnal SpO2 (89.9%, SD 3.4) was lower than mean daytime SpO2 in rest (92.1%, SD 2.9; P<.001). On average, SpO2 in rest ranged over 10.8% (SD 4.4) within one day. Highly varying CT90 values between different nights led to 50% (10/20) of the included patients changing categories between desaturator and nondesaturator over the course of 1 week. Conclusions: Continuous SpO2 measurements with wearable finger pulse oximeters identified significant SpO2 fluctuations between and within multiple days and nights of patients with COPD. Continuous SpO2 measurements during daily home routines of patients with COPD generally had high amounts of valid data, except for motion artifacts during MVPA. The identified fluctuations can have implications for telemonitoring applications that are based on daily SpO2 spot checks. CT90 values can vary greatly from night to night in patients with a nocturnal mean SpO2 around 90%, indicating that these patients cannot be consistently categorized as desaturators or nondesaturators. We recommend using wearable sensors for continuous SpO2 measurements over longer time periods to determine the clinical relevance of the identified SpO2 fluctuations.

27 March 2024 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
ASAn-Marie Schyvens
An-Marie Schyvens
COCatharina Nina Van Oost
Catharina Nina Van Oost
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts
FMFederica Masci
Federica Masci
BPBrent PETERS
Brent PETERS
JVJohan Verbraecken
Johan Verbraecken
Background: Despite being the gold-standard method for objectively assessing sleep, polysomnography (PSG) faces several limitations as it is expensive, time-consuming, and labor-intensive; requires various equipment and technical expertise; and is impractical for long-term or in-home use. Consumer wrist-worn wearables are able to monitor sleep parameters and thus could be used as an alternative for PSG. Consequently, wearables gained immense popularity over the past few years, but their accuracy has been a major concern. Objective: A systematic review of the literature was conducted to appraise the performance of 3 recent-generation wearable devices (Fitbit Charge 4, Garmin Vivosmart 4, and WHOOP) in determining sleep parameters and sleep stages. Methods: Per the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement, a comprehensive search was conducted using the PubMed, Web of Science, Google Scholar, Scopus, and Embase databases. Eligible publications were those that (1) involved the validity of sleep data of any marketed model of the candidate wearables and (2) used PSG or an ambulatory electroencephalogram monitor as a reference sleep monitoring device. Exclusion criteria were as follows: (1) incorporated a sleep diary or survey method as a reference, (2) review paper, (3) children as participants, and (4) duplicate publication of the same data and findings. Results: The search yielded 504 candidate articles. After eliminating duplicates and applying the eligibility criteria, 8 articles were included. WHOOP showed the least disagreement relative to PSG and Sleep Profiler for total sleep time (−1.4 min), light sleep (−9.6 min), and deep sleep (−9.3 min) but showed the largest disagreement for rapid eye movement (REM) sleep (21.0 min). Fitbit Charge 4 and Garmin Vivosmart 4 both showed moderate accuracy in assessing sleep stages and total sleep time compared to PSG. Fitbit Charge 4 showed the least disagreement for REM sleep (4.0 min) relative to PSG. Additionally, Fitbit Charge 4 showed higher sensitivities to deep sleep (75%) and REM sleep (86.5%) compared to Garmin Vivosmart 4 and WHOOP. Conclusions: The findings of this systematic literature review indicate that the devices with higher relative agreement and sensitivities to multistate sleep (ie, Fitbit Charge 4 and WHOOP) seem appropriate for deriving suitable estimates of sleep parameters. However, analyses regarding the multistate categorization of sleep indicate that all devices can benefit from further improvement in the assessment of specific sleep stages. Although providers are continuously developing new versions and variants of wearables, the scientific research on these wearables remains considerably limited. This scarcity in literature not only reduces our ability to draw definitive conclusions but also highlights the need for more targeted research in this domain. Additionally, future research endeavors should strive for standardized protocols including larger sample sizes to enhance the comparability and power of the results across studies.

27 March 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
GAGenet Tadese Aboye
Genet Tadese Aboye
GSGizeaddis Lamesgin Simegn
Gizeaddis Lamesgin Simegn
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts
Background: Digital technologies are increasingly being used to deliver health care services and promote public health. Mobile wireless technologies or mobile health (mHealth) technologies are particularly relevant owing to their ease of use, broad reach, and wide acceptance. Unlike developed countries, Sub-Saharan Africa experiences more challenges and obstacles when it comes to deploying, using, and expanding mHealth systems. In addition to barriers, there are enabling factors that could be exploited for the design, implementation, and scaling up of mHealth systems. Sub-Saharan Africa may require tailored solutions that address the specific challenges facing the region. Objective: The overall aim of this study was to identify the barriers and enablers for using mHealth systems in Sub-Saharan Africa from the perspectives of patients, physicians, and health care executives. Methods: Multi-level and multi-actor in-depth semistructured interviews were employed to qualitatively explore the barriers and enablers of the use of mHealth systems. Data were collected from patients, physicians, and health care executives. The interviews were audio recorded, transcribed verbatim, translated, and coded. Thematic analysis methodology was adopted, and NVivo software was used for the data analysis. Results: Through this rigorous study, a total of 137 determinants were identified. Of these determinants, 68 were identified as barriers and 69 were identified as enablers. Perceived barriers in patients included lack of awareness about mHealth systems and language barriers. Perceived enablers in patients included need for automated tools for health monitoring and an increasing literacy level of the society. According to physicians, barriers included lack of available digital health systems in the local context and concern about patients’ mHealth capabilities, while enablers included the perceived usefulness in reducing workload and improving health care service quality, as well as the availability of mobile devices and the internet. As perceived by health care executives, barriers included competing priorities alongside digitalization in the health sector and lack of interoperability and complete digitalization of implemented digital health systems, while enablers included the perceived usefulness of digitalization for the survival of the highly overloaded health care system and the abundance of educated manpower specializing in technology. Conclusions: mHealth systems in Sub-Saharan Africa are hindered and facilitated by various factors. Common barriers and enablers were identified by patients, physicians, and health care executives. To promote uptake, all relevant stakeholders must actively mitigate the barriers. This study identified a promising outlook for mHealth in Sub-Saharan Africa, despite the present barriers. Opportunities exist for successful integration into health care systems, and a user-centered design is crucial for maximum uptake.

1 August 2021 in Science of The Total Environment
Verified
Journal Article
Closed access
MSMichiel Stas
Michiel Stas
RARaf Aerts
Raf Aerts
MHMarijke Hendrickx
Marijke Hendrickx
ADAndy Delcloo
Andy Delcloo
NDNicolas Dendoncker
Nicolas Dendoncker
BSBen Somers
Ben Somers

16 September 2023 in Health Policy and Technology
Verified
Journal Article
Open access
GAGenet Tadese Aboye
Genet Tadese Aboye
MWMartijn Vande Walle
Martijn Vande Walle
GSGizeaddis Lamesgin Simegn
Gizeaddis Lamesgin Simegn
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts

1 September 2016 in Cytotherapy
Verified
Journal Article
Closed access
TLToon Lambrechts
Toon Lambrechts
IPIoannis Papantoniou
Ioannis Papantoniou
BRBrent Rice
Brent Rice
JSJan Schrooten
Jan Schrooten
FLFrank P. Luyten
Frank P. Luyten
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts