An-Marie Schyvens

Ms. An-Marie Schyvens


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2024 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
ASAn-Marie Schyvens
An-Marie Schyvens
COCatharina Nina Van Oost
Catharina Nina Van Oost
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts
FMFederica Masci
Federica Masci
BPBrent PETERS
Brent PETERS
JVJohan Verbraecken
Johan Verbraecken
Background: Despite being the gold-standard method for objectively assessing sleep, polysomnography (PSG) faces several limitations as it is expensive, time-consuming, and labor-intensive; requires various equipment and technical expertise; and is impractical for long-term or in-home use. Consumer wrist-worn wearables are able to monitor sleep parameters and thus could be used as an alternative for PSG. Consequently, wearables gained immense popularity over the past few years, but their accuracy has been a major concern. Objective: A systematic review of the literature was conducted to appraise the performance of 3 recent-generation wearable devices (Fitbit Charge 4, Garmin Vivosmart 4, and WHOOP) in determining sleep parameters and sleep stages. Methods: Per the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement, a comprehensive search was conducted using the PubMed, Web of Science, Google Scholar, Scopus, and Embase databases. Eligible publications were those that (1) involved the validity of sleep data of any marketed model of the candidate wearables and (2) used PSG or an ambulatory electroencephalogram monitor as a reference sleep monitoring device. Exclusion criteria were as follows: (1) incorporated a sleep diary or survey method as a reference, (2) review paper, (3) children as participants, and (4) duplicate publication of the same data and findings. Results: The search yielded 504 candidate articles. After eliminating duplicates and applying the eligibility criteria, 8 articles were included. WHOOP showed the least disagreement relative to PSG and Sleep Profiler for total sleep time (−1.4 min), light sleep (−9.6 min), and deep sleep (−9.3 min) but showed the largest disagreement for rapid eye movement (REM) sleep (21.0 min). Fitbit Charge 4 and Garmin Vivosmart 4 both showed moderate accuracy in assessing sleep stages and total sleep time compared to PSG. Fitbit Charge 4 showed the least disagreement for REM sleep (4.0 min) relative to PSG. Additionally, Fitbit Charge 4 showed higher sensitivities to deep sleep (75%) and REM sleep (86.5%) compared to Garmin Vivosmart 4 and WHOOP. Conclusions: The findings of this systematic literature review indicate that the devices with higher relative agreement and sensitivities to multistate sleep (ie, Fitbit Charge 4 and WHOOP) seem appropriate for deriving suitable estimates of sleep parameters. However, analyses regarding the multistate categorization of sleep indicate that all devices can benefit from further improvement in the assessment of specific sleep stages. Although providers are continuously developing new versions and variants of wearables, the scientific research on these wearables remains considerably limited. This scarcity in literature not only reduces our ability to draw definitive conclusions but also highlights the need for more targeted research in this domain. Additionally, future research endeavors should strive for standardized protocols including larger sample sizes to enhance the comparability and power of the results across studies.

22 March 2025 in SLEEP Advances
Verified
Journal Article
Open access
ASAn-Marie Schyvens
An-Marie Schyvens
BPBrent Peters
Brent Peters
NONina Catharina Van Oost
Nina Catharina Van Oost
JAJean-Marie Aerts
Jean-Marie Aerts
FMFederica Masci
Federica Masci
JVJohan Verbraecken
Johan Verbraecken
Study Objectives: The aim of this study is to assess the performance of six different consumer wearable sleep-tracking devices, namely the Fitbit Charge 5, Fitbit Sense, Withings Scanwatch, Garmin Vivosmart 4, Whoop 4.0, and the Apple Watch Series 8, for detecting sleep parameters compared to the gold standard, polysomnography (PSG). Methods: Sixty-two adults (52 males and 10 females, mean age ± SD = 46.0 ± 12.6 years) spent a single night in the sleep laboratory with PSG while simultaneously using two to four wearable devices. Results: The results indicate that most wearables displayed significant differences with PSG for total sleep time, sleep efficiency, wake after sleep onset, and light sleep (LS). Nevertheless, all wearables demonstrated a higher percentage of correctly identified epochs for deep sleep and rapid eye movement sleep compared to wake (W) and LS. All devices detected >90% of sleep epochs (ie, sensitivity), but showed lower specificity (29.39%–52.15%). The Cohen’s kappa coefficients of the wearable devices ranged from 0.21 to 0.53, indicating fair to moderate agreement with PSG. Conclusions: Our results indicate that all devices can benefit from further improvement for multistate categorization. However, the devices with higher Cohen’s kappa coefficients, such as the Fitbit Sense (κ = 0.42), Fitbit Charge 5 (κ = 0.41), and Apple Watch Series 8 (κ = 0.53), could be effectively used to track prolonged and significant changes in sleep architecture.

13 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
COCatharina Nina Van Oost
Catharina Nina Van Oost
FMFederica Masci
Federica Masci
AMAdelien Malisse
Adelien Malisse
ASAn-Marie Schyvens
An-Marie Schyvens
BPBrent PETERS
Brent PETERS
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts
Wearable devices are increasingly used for health and stress monitoring, yet their accuracy under dynamic, real-world conditions remains uncertain. This study validated the heart rate measurement accuracy of one chest-worn device (Zephyr BioHarness 3.0), a research-grade wrist-worn device (EmbracePlus), and five commercial wrist-worn wearable devices (Fitbit Charge 5, Fitbit Sense 2, Garmin Vivosmart 4, WHOOP 4.0, and Withings Scanwatch) against a 12-lead ECG using a 20 min protocol simulating real-life dynamics, including rest and varied-intensity walking. Device performance was evaluated across the full protocol and during transient states, defined as periods of rapid heart rate change. Accuracy and agreement were evaluated across per-second, 10 s, and 60 s resolutions. The Zephyr device showed a strong performance during all dynamic conditions. Among the wrist-worn devices, the Fitbit Charge 5 and Sense 2 showed the highest accuracy overall, while the Garmin Vivosmart 4 demonstrated greater stability during transitions. The WHOOP 4.0, Withings Scanwatch, and EmbracePlus devices performed acceptably during steady-state conditions, but were less accurate during transitions. Performance notably declined across all wrist-worn devices during transient states, with motion onset and large step changes in heart rate exacerbating measurement errors. Larger averaging windows improved accuracy by smoothing variability. The findings underscore that wrist-worn wearable devices may be better suited for average and trend heart rate monitoring rather than capturing acute dynamics. However, the Garmin and Fitbit devices showed suitable when requiring moderate accuracy during dynamic conditions. These results highlight the importance of context-specific validation and informed device selection to ensure effective use in health and stress-related applications.

22 August 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Alam ZebAlam Zeb
Alam Zeb
ANAn Neven
An Neven
CBChris Burtin
Chris Burtin
LJLotte Janssens
Lotte Janssens
BPBrent PETERS
Brent PETERS
JVJonas Verbrugghe
Jonas Verbrugghe
This study assessed the feasibility of a technology-supported high-intensity interval training (HIIT) program for occupational drivers. A multiphase feasibility study incorporating participant feedback was conducted in Flanders, Belgium, including consultation, pilot, and intervention phases. Occupational drivers were randomized to a HIIT group, an active control group (mindfulness program), or a passive control group (no intervention). The 16-week, equipment-free HIIT program consisted of two 15-min sessions per week, delivered via a technology-supported mobile application, preceded by a 2-week baseline. Primary feasibility outcomes included program completion, session adherence, intervention fidelity, adverse events, and participant experiences, while changes in health-related outcomes were assessed as secondary exploratory outcomes using validated questionnaires. During the consultation (n = 11) and pilot (n = 2) phases, participants reported positive attitudes toward the intervention. Key barriers, including scheduling constraints (n = 5) and bicycle transportation (n = 4), informed refinements such as an equipment-free, technology-supported protocol and flexible scheduling. Of the 23 randomized participants across all groups, 16 participants initiated their assigned study protocol, and 10 completed all assessment points and were included in the final analysis. Of the nine participants allocated to the HIIT group, four initiated the intervention (44.4%), and three completed the program (33.3% of those allocated; 75% of those who initiated). Among the three completers, mean session attendance was 80.2%. Session fidelity was well maintained, but exercise-intensity fidelity could not be objectively confirmed. No exercise-related adverse events were reported. Participant feedback indicated generally positive usability but mixed acceptability of the technology-supported HIIT program among the three participants who completed the intervention. Exploratory individual-level changes in health-related outcomes were heterogeneous, with lower mean scores for depression, anxiety, stress, and fatigue. A technology-supported HIIT program was feasible among the small subgroup of occupational drivers who initiated it, with high session attendance. However, considerable pre-initiation attrition and low retention limit its feasibility for the broader target population. Observed health-related outcomes were heterogeneous and should be interpreted descriptively, warranting evaluation in a fully powered randomized controlled trial.

16 October 2025 in ERJ Open Research
Verified
Journal Article
Open access
FVFrederik Veys
Frederik Veys
ASAn-Marie Schyvens
An-Marie Schyvens
IVIlse De Volder
Ilse De Volder
AGAnn Van Gastel
Ann Van Gastel
Marijke DieltjensMarijke Dieltjens
Marijke Dieltjens
JVJohan Verbraecken
Johan Verbraecken
Background: Type D personality, characterised by social inhibition and negative affectivity, has been linked to lower compliance with continuous positive airway pressure (CPAP) and mandibular advancement device treatment, and increased side-effects in obstructive sleep apnoea (OSA) patients. Bilevel positive airway pressure (BiPAP) is often prescribed as an alternative when CPAP is poorly tolerated. However, the influence of type D personality on BiPAP compliance and related side-effects has not been studied. Regarding overall treatment success, mean disease alleviation (MDA) must also be considered. Methods: An observational cohort study was conducted in 365 adult patients with OSA or central sleep apnoea who received BiPAP therapy. Type D personality was assessed using the 14-item Type D Scale questionnaire. Data were collected from medical patient records. Compliant users were defined as patients using the device for ≥4 h·night −1 . MDA was calculated by multiplying therapeutic efficacy and adjusted compliance. Side-effects were assessed through patient-reported questionnaires. Results: The cohort included 291 men and 74 women (mean± sd age 56±12 years, median body mass index 32.0 (interquartile range (IQR) 28.7–36.7) kg·m −2 , median baseline apnoea–hypopnoea index 44.7 (IQR 28.1–66.7) events·h −1 ). Type D personality was present in 33% of the cohort. BiPAP compliance was significantly lower in the type D group (median 5.94, IQR 3.29–7.22 h·night −1 ) compared to the non-type D group (6.27, 4.53–7.63 h·night −1 ; p=0.023). Six out of 19 studied side-effects were significantly more common in type D patients, with another 12 side-effects showing a trend to higher prevalence. Conclusion: In conclusion, type D personality significantly lowers BiPAP compliance and increases occurrence of side-effects.

3 September 2025
Verified
Book Chapter
Open access
PDF file
BPBrent PETERS
Brent PETERS
ANAn Neven
An Neven
HDHélène Dirix
Hélène Dirix
VRVeerle Ross
Veerle Ross
JVJohan Verbraecken
Johan Verbraecken
GWGeert Wets
Geert Wets
European occupational road freight drivers face difficulties such as traffic jams, deadlines and demanding customers during their job. Therefore, they often suffer from stress, a problem that may worsen as traffic increases. Europe has a severe driver shortage, so insight into the issues of occupational drivers is needed to improve their working conditions. Through two online focus group discussions with eleven occupational drivers, this study gathered data on stressors and strategies against stress. The data was analysed through thematic analysis, revealing four different stressor types: stressors related to company operations (e.g. dispatching issues), job tasks (e.g. time-related stressors), client-related factors (e.g. disrespect from the client), and non-work-related stressors (e.g. an ill partner). Strategies against stress include coping strategies (e.g. social contact) and solutions such as an improved attitude towards freight drivers, improved communication between drivers and other parties, better equipment and facilities and changes to the law. The insights of this study about occupational driver stressors could be used for e.g. intervention development.