Federica Masci

Dr. Federica Masci


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2024 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
ASAn-Marie Schyvens
An-Marie Schyvens
COCatharina Nina Van Oost
Catharina Nina Van Oost
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts
FMFederica Masci
Federica Masci
BPBrent PETERS
Brent PETERS
JVJohan Verbraecken
Johan Verbraecken
Background: Despite being the gold-standard method for objectively assessing sleep, polysomnography (PSG) faces several limitations as it is expensive, time-consuming, and labor-intensive; requires various equipment and technical expertise; and is impractical for long-term or in-home use. Consumer wrist-worn wearables are able to monitor sleep parameters and thus could be used as an alternative for PSG. Consequently, wearables gained immense popularity over the past few years, but their accuracy has been a major concern. Objective: A systematic review of the literature was conducted to appraise the performance of 3 recent-generation wearable devices (Fitbit Charge 4, Garmin Vivosmart 4, and WHOOP) in determining sleep parameters and sleep stages. Methods: Per the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement, a comprehensive search was conducted using the PubMed, Web of Science, Google Scholar, Scopus, and Embase databases. Eligible publications were those that (1) involved the validity of sleep data of any marketed model of the candidate wearables and (2) used PSG or an ambulatory electroencephalogram monitor as a reference sleep monitoring device. Exclusion criteria were as follows: (1) incorporated a sleep diary or survey method as a reference, (2) review paper, (3) children as participants, and (4) duplicate publication of the same data and findings. Results: The search yielded 504 candidate articles. After eliminating duplicates and applying the eligibility criteria, 8 articles were included. WHOOP showed the least disagreement relative to PSG and Sleep Profiler for total sleep time (−1.4 min), light sleep (−9.6 min), and deep sleep (−9.3 min) but showed the largest disagreement for rapid eye movement (REM) sleep (21.0 min). Fitbit Charge 4 and Garmin Vivosmart 4 both showed moderate accuracy in assessing sleep stages and total sleep time compared to PSG. Fitbit Charge 4 showed the least disagreement for REM sleep (4.0 min) relative to PSG. Additionally, Fitbit Charge 4 showed higher sensitivities to deep sleep (75%) and REM sleep (86.5%) compared to Garmin Vivosmart 4 and WHOOP. Conclusions: The findings of this systematic literature review indicate that the devices with higher relative agreement and sensitivities to multistate sleep (ie, Fitbit Charge 4 and WHOOP) seem appropriate for deriving suitable estimates of sleep parameters. However, analyses regarding the multistate categorization of sleep indicate that all devices can benefit from further improvement in the assessment of specific sleep stages. Although providers are continuously developing new versions and variants of wearables, the scientific research on these wearables remains considerably limited. This scarcity in literature not only reduces our ability to draw definitive conclusions but also highlights the need for more targeted research in this domain. Additionally, future research endeavors should strive for standardized protocols including larger sample sizes to enhance the comparability and power of the results across studies.

FMFederica Masci
Federica Masci
Spatari GiovannaSpatari Giovanna
Spatari Giovanna
SBSara Bortolotti
Sara Bortolotti
GCGiorgianni Concetto
Giorgianni Concetto
Laura Maria AntonangeliLaura Maria Antonangeli
Laura Maria Antonangeli
Claudio ColosioClaudio Colosio
Claudio Colosio
Occupational logging activities expose workers to a wide range of risk factors, such as lifting heavy loads, prolonged, awkward positioning of the lower back, repetitive movements, and insufficient work pauses. Body posture has an important impact on the level of physiological load. The present study involved a group of 40 loggers in the province of Enna (Sicily, Italy) with the aim of defining the impact of logging activities on the workers’ physiological strain during the three primary work tasks of felling, delimbing, and bucking. The Zephyr Bioharness measurement system was used to record trunk posture and heart rate data during work tasks. The NASA TLX questionnaire was used to explore workers’ effort perception of the work tasks. Based on our results, the most demanding work task was tree felling, which requires a higher level of cardiac cost and longer periods spent in awkward trunk postures. The perceived physiological workload was consistently underestimated, especially by the more experienced loggers. Lastly, as the weight of the chainsaw increased, the cardiac load increased.

13 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
COCatharina Nina Van Oost
Catharina Nina Van Oost
FMFederica Masci
Federica Masci
AMAdelien Malisse
Adelien Malisse
ASAn-Marie Schyvens
An-Marie Schyvens
BPBrent PETERS
Brent PETERS
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts
Wearable devices are increasingly used for health and stress monitoring, yet their accuracy under dynamic, real-world conditions remains uncertain. This study validated the heart rate measurement accuracy of one chest-worn device (Zephyr BioHarness 3.0), a research-grade wrist-worn device (EmbracePlus), and five commercial wrist-worn wearable devices (Fitbit Charge 5, Fitbit Sense 2, Garmin Vivosmart 4, WHOOP 4.0, and Withings Scanwatch) against a 12-lead ECG using a 20 min protocol simulating real-life dynamics, including rest and varied-intensity walking. Device performance was evaluated across the full protocol and during transient states, defined as periods of rapid heart rate change. Accuracy and agreement were evaluated across per-second, 10 s, and 60 s resolutions. The Zephyr device showed a strong performance during all dynamic conditions. Among the wrist-worn devices, the Fitbit Charge 5 and Sense 2 showed the highest accuracy overall, while the Garmin Vivosmart 4 demonstrated greater stability during transitions. The WHOOP 4.0, Withings Scanwatch, and EmbracePlus devices performed acceptably during steady-state conditions, but were less accurate during transitions. Performance notably declined across all wrist-worn devices during transient states, with motion onset and large step changes in heart rate exacerbating measurement errors. Larger averaging windows improved accuracy by smoothing variability. The findings underscore that wrist-worn wearable devices may be better suited for average and trend heart rate monitoring rather than capturing acute dynamics. However, the Garmin and Fitbit devices showed suitable when requiring moderate accuracy during dynamic conditions. These results highlight the importance of context-specific validation and informed device selection to ensure effective use in health and stress-related applications.

3 September 2025
Verified
Book Chapter
Open access
PDF file
BPBrent PETERS
Brent PETERS
ANAn Neven
An Neven
HDHélène Dirix
Hélène Dirix
VRVeerle Ross
Veerle Ross
JVJohan Verbraecken
Johan Verbraecken
GWGeert Wets
Geert Wets
European occupational road freight drivers face difficulties such as traffic jams, deadlines and demanding customers during their job. Therefore, they often suffer from stress, a problem that may worsen as traffic increases. Europe has a severe driver shortage, so insight into the issues of occupational drivers is needed to improve their working conditions. Through two online focus group discussions with eleven occupational drivers, this study gathered data on stressors and strategies against stress. The data was analysed through thematic analysis, revealing four different stressor types: stressors related to company operations (e.g. dispatching issues), job tasks (e.g. time-related stressors), client-related factors (e.g. disrespect from the client), and non-work-related stressors (e.g. an ill partner). Strategies against stress include coping strategies (e.g. social contact) and solutions such as an improved attitude towards freight drivers, improved communication between drivers and other parties, better equipment and facilities and changes to the law. The insights of this study about occupational driver stressors could be used for e.g. intervention development.

16 June 2025 in One Health
Verified
Journal Article
Open access
FMFederica Masci
Federica Masci
JGJ. Gielen
J. Gielen
GAG. Tadese Aboye
G. Tadese Aboye
JAJ.M. Aerts
J.M. Aerts
The integration of digital tools in healthcare is profoundly reshaping global health systems, particularly within the One Health framework, which emphasizes the interconnectedness of human, animal, and environmental health. This article advocates for transitioning from a “human-centered” to a “humanity-centered” design approach to address the multifaceted health challenges faced by diverse populations. By embracing this paradigm, the article underscores the potential of digital health technologies to reduce health inequities, promote inclusivity, and foster multisectorial collaboration. It further highlights the necessity of bridging the digital divide to ensure that innovations are both equitable and sustainable, aligning with the overarching goals of global health advancement.

24 July 2025
Verified
Book Chapter
Closed access
PDF file
FMFederica Masci
Federica Masci
NONina Van Oost
Nina Van Oost
JWJenna Van Win
Jenna Van Win
ASAn-Marie Schyvens
An-Marie Schyvens
BPBrent PETERS
Brent PETERS
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts