Catharina Nina Van Oost

Ms. Catharina Nina Van Oost

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2024 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
ASAn-Marie Schyvens
An-Marie Schyvens
COCatharina Nina Van Oost
Catharina Nina Van Oost
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts
FMFederica Masci
Federica Masci
BPBrent PETERS
Brent PETERS
JVJohan Verbraecken
Johan Verbraecken
Background: Despite being the gold-standard method for objectively assessing sleep, polysomnography (PSG) faces several limitations as it is expensive, time-consuming, and labor-intensive; requires various equipment and technical expertise; and is impractical for long-term or in-home use. Consumer wrist-worn wearables are able to monitor sleep parameters and thus could be used as an alternative for PSG. Consequently, wearables gained immense popularity over the past few years, but their accuracy has been a major concern. Objective: A systematic review of the literature was conducted to appraise the performance of 3 recent-generation wearable devices (Fitbit Charge 4, Garmin Vivosmart 4, and WHOOP) in determining sleep parameters and sleep stages. Methods: Per the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) statement, a comprehensive search was conducted using the PubMed, Web of Science, Google Scholar, Scopus, and Embase databases. Eligible publications were those that (1) involved the validity of sleep data of any marketed model of the candidate wearables and (2) used PSG or an ambulatory electroencephalogram monitor as a reference sleep monitoring device. Exclusion criteria were as follows: (1) incorporated a sleep diary or survey method as a reference, (2) review paper, (3) children as participants, and (4) duplicate publication of the same data and findings. Results: The search yielded 504 candidate articles. After eliminating duplicates and applying the eligibility criteria, 8 articles were included. WHOOP showed the least disagreement relative to PSG and Sleep Profiler for total sleep time (−1.4 min), light sleep (−9.6 min), and deep sleep (−9.3 min) but showed the largest disagreement for rapid eye movement (REM) sleep (21.0 min). Fitbit Charge 4 and Garmin Vivosmart 4 both showed moderate accuracy in assessing sleep stages and total sleep time compared to PSG. Fitbit Charge 4 showed the least disagreement for REM sleep (4.0 min) relative to PSG. Additionally, Fitbit Charge 4 showed higher sensitivities to deep sleep (75%) and REM sleep (86.5%) compared to Garmin Vivosmart 4 and WHOOP. Conclusions: The findings of this systematic literature review indicate that the devices with higher relative agreement and sensitivities to multistate sleep (ie, Fitbit Charge 4 and WHOOP) seem appropriate for deriving suitable estimates of sleep parameters. However, analyses regarding the multistate categorization of sleep indicate that all devices can benefit from further improvement in the assessment of specific sleep stages. Although providers are continuously developing new versions and variants of wearables, the scientific research on these wearables remains considerably limited. This scarcity in literature not only reduces our ability to draw definitive conclusions but also highlights the need for more targeted research in this domain. Additionally, future research endeavors should strive for standardized protocols including larger sample sizes to enhance the comparability and power of the results across studies.

13 October 2025 in Sensors
Verified
Journal Article
Open access
PDF file
COCatharina Nina Van Oost
Catharina Nina Van Oost
FMFederica Masci
Federica Masci
AMAdelien Malisse
Adelien Malisse
ASAn-Marie Schyvens
An-Marie Schyvens
BPBrent PETERS
Brent PETERS
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts
Wearable devices are increasingly used for health and stress monitoring, yet their accuracy under dynamic, real-world conditions remains uncertain. This study validated the heart rate measurement accuracy of one chest-worn device (Zephyr BioHarness 3.0), a research-grade wrist-worn device (EmbracePlus), and five commercial wrist-worn wearable devices (Fitbit Charge 5, Fitbit Sense 2, Garmin Vivosmart 4, WHOOP 4.0, and Withings Scanwatch) against a 12-lead ECG using a 20 min protocol simulating real-life dynamics, including rest and varied-intensity walking. Device performance was evaluated across the full protocol and during transient states, defined as periods of rapid heart rate change. Accuracy and agreement were evaluated across per-second, 10 s, and 60 s resolutions. The Zephyr device showed a strong performance during all dynamic conditions. Among the wrist-worn devices, the Fitbit Charge 5 and Sense 2 showed the highest accuracy overall, while the Garmin Vivosmart 4 demonstrated greater stability during transitions. The WHOOP 4.0, Withings Scanwatch, and EmbracePlus devices performed acceptably during steady-state conditions, but were less accurate during transitions. Performance notably declined across all wrist-worn devices during transient states, with motion onset and large step changes in heart rate exacerbating measurement errors. Larger averaging windows improved accuracy by smoothing variability. The findings underscore that wrist-worn wearable devices may be better suited for average and trend heart rate monitoring rather than capturing acute dynamics. However, the Garmin and Fitbit devices showed suitable when requiring moderate accuracy during dynamic conditions. These results highlight the importance of context-specific validation and informed device selection to ensure effective use in health and stress-related applications.

17 February 2026 in JMIR Formative Research
Verified
Journal Article
Open access
JGJasper Gielen
Jasper Gielen
COCatharina Nina Van Oost
Catharina Nina Van Oost
GDGlen Debard
Glen Debard
RSRomy Sels
Romy Sels
NWNele A J De Witte
Nele A J De Witte
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts
Background: Commercial wearable devices allow for continuous heart rate (HR) monitoring in daily life. Their accuracy under ecologically valid conditions, however, remains insufficiently independently tested, especially during irregular activity, cognitive stress, and variable climates. Objective: This study evaluated the HR accuracy of 10 commercially available wearables under controlled variations in physical activity, cognitive stress, and temperature. We hypothesized that physical activity irregularity, cognitive stress, and thermal climate conditions would affect measurement accuracy. Methods: Forty-five healthy adults (21‐68, mean 34, SD 12 y) completed a standardized protocol in climate-controlled chambers simulating neutral (23 °C), hot (36 °C), and cold (10 °C) conditions. Tasks included rest, cognitive stress (Montreal Imaging Stress Task), steady walking, and intermittent walking. Each of the 10 devices (Fitbit Charge 6, Fitbit Inspire 3, Garmin Vivosmart 5, Garmin Vivoactive 5, Apple Watch SE, Google Pixel Watch 2, Polar Ignite 3, Polar Pacer, Xiaomi Watch 2, and Oura Ring Gen 3) was compared against electrocardiogram-derived HR from a Zephyr BioHarness chest strap. Accuracy was assessed using mean absolute error (MAE), mean absolute percentage error (MAPE), repeated-measures concordance correlation coefficient (CCC), and Bland-Altman analysis. Results: Significant variability across the devices was observed. Fitbit Charge 6 (MAE 4.5 bpm, MAPE 5.5%, CCC 0.93) and Google Pixel Watch 2 (MAE 4.9 bpm, MAPE 6.7%, CCC 0.87) showed strong agreement with the gold standard. In contrast, Fitbit Inspire 3, Polar Ignite 3, Polar Pacer, and Oura Ring displayed larger errors (MAE 9‐14 bpm, MAPE 11%‐16%) and lower CCC values (0.45‐0.66). The climate conditions did not significantly affect the measurement accuracy of the test devices. The activity type, however, did have a significant effect: intermittent walking increased errors for multiple devices. Conclusions: Wearable HR measurement accuracy is device-specific and context-dependent. Moderate climates did not impair performance, but irregular movement reduced accuracy. Fitbit Charge 6 and Google Pixel Watch 2 demonstrated the highest reliability, supporting their use in health and sports monitoring. Careful device selection and context-aware interpretation remain critical for applied and clinical applications.

22 August 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Alam ZebAlam Zeb
Alam Zeb
ANAn Neven
An Neven
CBChris Burtin
Chris Burtin
LJLotte Janssens
Lotte Janssens
BPBrent PETERS
Brent PETERS
JVJonas Verbrugghe
Jonas Verbrugghe
This study assessed the feasibility of a technology-supported high-intensity interval training (HIIT) program for occupational drivers. A multiphase feasibility study incorporating participant feedback was conducted in Flanders, Belgium, including consultation, pilot, and intervention phases. Occupational drivers were randomized to a HIIT group, an active control group (mindfulness program), or a passive control group (no intervention). The 16-week, equipment-free HIIT program consisted of two 15-min sessions per week, delivered via a technology-supported mobile application, preceded by a 2-week baseline. Primary feasibility outcomes included program completion, session adherence, intervention fidelity, adverse events, and participant experiences, while changes in health-related outcomes were assessed as secondary exploratory outcomes using validated questionnaires. During the consultation (n = 11) and pilot (n = 2) phases, participants reported positive attitudes toward the intervention. Key barriers, including scheduling constraints (n = 5) and bicycle transportation (n = 4), informed refinements such as an equipment-free, technology-supported protocol and flexible scheduling. Of the 23 randomized participants across all groups, 16 participants initiated their assigned study protocol, and 10 completed all assessment points and were included in the final analysis. Of the nine participants allocated to the HIIT group, four initiated the intervention (44.4%), and three completed the program (33.3% of those allocated; 75% of those who initiated). Among the three completers, mean session attendance was 80.2%. Session fidelity was well maintained, but exercise-intensity fidelity could not be objectively confirmed. No exercise-related adverse events were reported. Participant feedback indicated generally positive usability but mixed acceptability of the technology-supported HIIT program among the three participants who completed the intervention. Exploratory individual-level changes in health-related outcomes were heterogeneous, with lower mean scores for depression, anxiety, stress, and fatigue. A technology-supported HIIT program was feasible among the small subgroup of occupational drivers who initiated it, with high session attendance. However, considerable pre-initiation attrition and low retention limit its feasibility for the broader target population. Observed health-related outcomes were heterogeneous and should be interpreted descriptively, warranting evaluation in a fully powered randomized controlled trial.

3 September 2025
Verified
Book Chapter
Open access
PDF file
BPBrent PETERS
Brent PETERS
ANAn Neven
An Neven
HDHélène Dirix
Hélène Dirix
VRVeerle Ross
Veerle Ross
JVJohan Verbraecken
Johan Verbraecken
GWGeert Wets
Geert Wets
European occupational road freight drivers face difficulties such as traffic jams, deadlines and demanding customers during their job. Therefore, they often suffer from stress, a problem that may worsen as traffic increases. Europe has a severe driver shortage, so insight into the issues of occupational drivers is needed to improve their working conditions. Through two online focus group discussions with eleven occupational drivers, this study gathered data on stressors and strategies against stress. The data was analysed through thematic analysis, revealing four different stressor types: stressors related to company operations (e.g. dispatching issues), job tasks (e.g. time-related stressors), client-related factors (e.g. disrespect from the client), and non-work-related stressors (e.g. an ill partner). Strategies against stress include coping strategies (e.g. social contact) and solutions such as an improved attitude towards freight drivers, improved communication between drivers and other parties, better equipment and facilities and changes to the law. The insights of this study about occupational driver stressors could be used for e.g. intervention development.

26 February 2026 in JMIR Preprints
Verified
Preprint
Open access
TCToon Colman
Toon Colman
TDTom Van Daele
Tom Van Daele
BBBert Bonroy
Bert Bonroy
Jean-Marie AertsJean-Marie Aerts
Jean-Marie Aerts
GDGlen Debard
Glen Debard
NWNele A J De Witte
Nele A J De Witte
BACKGROUND Smartphone-based self-assessment methods, such as ecological momentary assessment (EMA), are increasingly used to measure perceived stress in research and emerging clinical applications. However, the proliferation of studies and methods has made it difficult for researchers and practitioners to maintain an overview and make informed methodological choices. An updated synthesis of smartphone-based self-report methods is therefore needed. OBJECTIVE This scoping review aims to systematically map smartphone-based methods for assessing self-reported perceived stress in healthy adults during daily life, to describe measurement characteristics and methodological choices, and to narratively examine the extent to which validity and reliability evidence are reported. METHODS Following PRISMA‑ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews) guidelines, we searched a total of 7 databases: Web of Science, Embase, MEDLINE, PubMed, IEEE Xplore, ACM, and PsycInfo. Eligible studies assessed general perceived stress in healthy adults using smartphone-based self-report measures in daily life. Screening was conducted independently by at least 2 reviewers at the abstract and full‑text levels. Methodological characteristics of stress measurement were extracted and summarized descriptively. RESULTS From 8777 deduplicated records, 108 studies met all eligibility criteria. Publication frequency increased notably over the review period. Most studies used observational designs, with EMA-style prompting schedules. Stress was typically assessed using very brief measures: most instruments (84/114, 74%) consisted of a single item, most commonly answered using a Likert-type scale or a visual analog scale. Measurement frequency ranged from once per week to multiple prompts per day, with intensive approaches (≥3 prompts per day) being most common. Despite the prevalence of these instruments, only a minority of studies reported validity or reliability measures. When provided, evidence typically consisted of correlations with established stress questionnaires or affective measures. A small subset conducted elaborate psychometric analyses or validation of instruments. CONCLUSIONS Smartphone-based stress assessment is widespread but methodologically heterogeneous. This review provides an updated methodological overview to support researchers in selecting or developing robust smartphone-based measures of perceived stress. Only a small minority of studies reported formal psychometric evaluations, highlighting the need for more systematic validation of smartphone-based stress assessment. CLINICALTRIAL OSF Registries 7UM6B; https://osf.io/7um6b