Transmission lines are affected by external environmental factors such as strong winds and ice cover. In recent years, extreme weather events have increased, leading to recurrent disturbances in transmission lines because of wind deflection. These incidents have resulted in significant financial losses and have disrupted regular industrial and domestic activities. In this paper, the ANSYS Workbench 2020 R2 finite element analysis platform was used to establish a transmission line-hanging insulator string system model. Calculations on transmission lines were conducted considering variations in different stall spacing, height differences, wind speed, and the wind attack angle. The impact of these diverse factors on the wind deflection of insulators was scrutinized, leading to the derivation of patterns describing how the wind deflection angle shifts in response to changes in stall spacing, height differences, wind speed, and the wind attack angle. Based on the generalized linear regression network and particle swarm improved support vector machine algorithm, a meteorological prediction-based early warning method for wind deflection of transmission lines was proposed, a transmission line wind deflection early warning model was established, and the practical effect of the model was evaluated. The outcomes of this study provide crucial data for the formulation and development of ultra-high voltage (UHV) and extra-high voltage (EHV) transmission networks. Furthermore, they can contribute to the advanced detection of wind deflection issues.
Phase-to-ground discharge of transmission lines due to ice cover is a common issue. To assess the risk of phase-to-ground discharge of overhead lines under complex ice-covering conditions, this study used finite element analysis to model the interaction between ground wire, conductor, and insulator. The study examined how different factors affect the minimum safe distance between the conductor and ground wire, as well as the risk coefficient of phase-to-ground discharge and the risk zone. The finding reveals that as icing thickness increases, conductor bouncing intensifies, reducing the phase-to-ground distance, and placing one half of the line span within the risk zone for the given conditions. For the same length of de-icing, the closer the de-icing region is to the midpoint, the greater is the maximum jump height of the conductor. When the span is extended to 600 m, the risk range covers approximately 70% of the total line length. Under strong winds, conductor lateral displacement increases with wind speed, which leads to a higher risk of discharge.
The safety of transmission lines is a crucial guarantee for the operation of the power grid. To address the issue of low detection accuracy for icing transmission line defects with existing models, this paper proposes a defect detection algorithm for icing transmission line defects under different weather conditions based on a Large Dynamic Kernel Aggregation Net (LDKA-NET). First, a wide field of view convolutional network (WFVC Net) is introduced to enhance the network’s perception and generalization capabilities, enabling better adaptation to complex scene targets. Secondly, a full-dimensional dynamic convolutional feature fusion network is proposed, which strengthens the model’s feature extraction ability by learning linear combinations of multiple convolution kernels and their weighted input-related attention. Finally, an Expectation Maximization Dynamic Convolutional Attention (EM-DCA) mechanism is introduced, which focuses on and utilizes important information in the input data to help the model better allocate attention, thereby improving its generalization and robustness. Experimental results show that on the dataset proposed in this paper, the average accuracy of the improved algorithm (mAP@0.5) reaches 99.01%. The model parameters decreased by 47.7 M compared with the baseline model and 91.26 M compared with the Faster region with CNN feature (Faster R-CNN) model. The accuracy is 4.81% and 3.11% higher than the SSD model and YOLOv5-L model, respectively. Compared with the existing models, our model is smaller and has higher detection accuracy. It can accurately detect ice-covered wires and complete the task of the ice-covered detection of transmission lines.
This study presents an experimental investigation for the galloping performance of the transmission line system with rime under wind excitation. A full aeroelastic model wind-tunnel test is conducted to investigate the dynamic response of a two-bundled transmission line system with rime under different conditions. The time histories of the displacement of the conductor and the acceleration of the tower are measured in detail to analyze the characteristic of the wind-induced response. A comprehensive parametric experiment is performed to explore the effects of wind speed, wind direction, the number of conductor spans and the coupling between the conductor and the tower on the galloping performance of the transmission line system with rime. The results showed that the wind speed, wind direction and the number of conductor spans have significant influence on the galloping performance of conductor. The zero-degree wind direction is the most dangerous direction for the conductor. The multi-span conductor has different galloping initiation wind speed and vibration characteristics compared to the single-span conductor. The coupling effect between the conductor and the tower has trivial influence on the response of tower. This study uses 3D-printing models to simulate the aerodynamic shape of ice-covered wires with different thicknesses for wind-tunnel tests and obtains the influence of a series of parameters on the galloping vibration of transmission tower line systems.