Strong winds can lead to more complex ice shedding oscillation processes for overhead conductors, inducing flashovers, strand breakages and other accidents. This study analyzes the aerodynamic parameters of several typical icing features and establishes a numerical model for ice shedding on overhead conductors under strong wind conditions. The results show that for the same amount of icing, the resistance and lift force on the conductor changes with ice shape, wind attack angle and wind speed, which has a significant effect on the ice shedding jumping process. When the wind attack angle approaches 180°, the airflow resistance of the fan-shaped and D-shaped icing conductors significantly increases. And in the process of ice shedding response of transmission lines, the lateral amplitude may exceed 20 m, which increase the discharge risk of horizontally arranged conductors. Moreover, for the significant lateral oscillation of conductors by ice shedding under strong wind, the maximum horizontal displacement is approximately 1.6 times the difference in lateral position before and after ice shedding.
Icing is one of the key factors affecting the security and reliability of power system operation. Ice accumulation on the overhead line (OHL) conductors is often accompanied by strong winds, whose magnitude and direction are varied constantly, which imposes challenges to the on-line monitoring of OHL’s ice load. This paper analyzed the dynamic characteristics of the tensional force for ice accumulated OHLs through both the on-site experiment and the finite element method (FEM). The correlation between the instantaneous wind speed, the thickness of the accumulated ice and the dynamic tensional force, the aerodynamic resistance coefficient of the conductor, is investigated. It is found that the axial dynamic tension at the end of the iced conductor is approximately proportional to the square of the instantaneous wind speed. The higher the wind speed, the larger the difference between the static tension and the maximum dynamic tension calculated using the 10-min average wind speed. Under the conditions of the example in this article (crescent-shaped icing), when the average wind speed is 20 m/s, the ratio of the difference to static tension is 11.19%. These conclusions are verified with the computational fluid dynamic (CFD) simulation, the same correlation is identified in comparison with the experiments. Due to the fact that the magnitudes of tensional force and vibration are determined by the instantaneous wind speed, significant error exists within traditional calculation methods where average wind speed is used instead.
This study presents an experimental investigation for the galloping performance of the transmission line system with rime under wind excitation. A full aeroelastic model wind-tunnel test is conducted to investigate the dynamic response of a two-bundled transmission line system with rime under different conditions. The time histories of the displacement of the conductor and the acceleration of the tower are measured in detail to analyze the characteristic of the wind-induced response. A comprehensive parametric experiment is performed to explore the effects of wind speed, wind direction, the number of conductor spans and the coupling between the conductor and the tower on the galloping performance of the transmission line system with rime. The results showed that the wind speed, wind direction and the number of conductor spans have significant influence on the galloping performance of conductor. The zero-degree wind direction is the most dangerous direction for the conductor. The multi-span conductor has different galloping initiation wind speed and vibration characteristics compared to the single-span conductor. The coupling effect between the conductor and the tower has trivial influence on the response of tower. This study uses 3D-printing models to simulate the aerodynamic shape of ice-covered wires with different thicknesses for wind-tunnel tests and obtains the influence of a series of parameters on the galloping vibration of transmission tower line systems.
1 January 2025 in Computer Modeling in Engineering & Sciences
Ice cover on transmission lines is a significant issue that affects the safe operation of the power system. Accurate calculation of the thickness of wire icing can effectively prevent economic losses caused by ice disasters a... | Find, read and cite all the research you need on Tech Science Press
1 November 2024 in Intelligent Decision Technologies
With the explosive growth of electricity consumption, the demand for electricity by electricity users is increasing. As a core component of power supply, the safe and stable operation of transmission lines plays an important role in the normal operation of the entire power system. However, traditional monitoring methods for transmission line operation status face challenges such as limited accuracy, lack of real-time feedback, and high operational costs. In this paper, the Firefly algorithm is used to monitor the running status of transmission lines. Through synchronous testing with the traditional particle swarm optimization algorithm, it is found that the average accuracy of the Firefly algorithm in voltage and current measurement is improved to 93.13% and 93.66% respectively, which is better than the traditional algorithm. Firefly algorithm shows high precision in various power equipment monitoring, the average monitoring accuracy is 95.62% and 93.06%, respectively, which proves that it has stronger performance in transmission line monitoring and can achieve more stringent monitoring requirements. Through the comparison experiment of the algorithm, it proved that the Firefly algorithm had a strong performance in the transmission line operation status monitoring, and could more accurately identify the transmission line fault, which provided a new idea and new method for the safe operation status monitoring of transmission lines.
During late December 2021, an ice accretion disaster occurred in North Xinjiang, especially in the western part. It is found that the meteorological conditions suitable for the occurrence of ice accretion disasters are when the temperature is between −14 °C and −3 °C, the relative humidity is greater than 80%, the wind speed is between 4.5 m s−1 and 7.5 m s−1, and the pressure is between 919 hPa and 928 hPa. The ice accretion disaster is influenced by large-scale circulation, including the two-trough and one-ridge geopotential height structure in the middle troposphere and the spatially moving Ural Mountain blocking high pressure. Furthermore, using the artificial intelligence-based Pangu model and machine learning algorithms within the application of multiple linear regression and the leave-ten-out cross-validation, a skillful forecast correction model for ice accretion thickness in North Xinjiang is constructed. The prediction model has significant prediction skill for ice accretion thickness in North Xinjiang with 24 h, 48 h, and even 72 h in advance. The findings of the study can improve the timeliness of business system in the short-term and immediate forecast of ice accretion thickness, providing more reliable technical support for the ice prevention and disaster reduction of the power grids.