Erkan Mozioglu

Dr. Erkan Mozioglu

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2011 in Phytochemistry Letters
Verified
Journal Article
Closed access
AGAhmet Ceyhan Goren
Ahmet Ceyhan Goren
FPFranco Piozzi
Franco Piozzi
EAEkrem Akcicek
Ekrem Akcicek
TKTurgut Kılıç
Turgut Kılıç
SÇSema ÇARIKÇI
Sema ÇARIKÇI
WSWilliam N. Setzer
William N. Setzer

1 April 2017 in Food Chemistry
Verified
Journal Article
Closed access
BYBurhanettin Yalçınkaya
Burhanettin Yalçınkaya
EYEylem Yumbul
Eylem Yumbul
EMErkan Mozioglu
Erkan Mozioglu
MAMuslum Akgoz
Muslum Akgoz

3 August 2016 in BMC Infectious Diseases
Verified
Journal Article
Open access
PDF file
ADAlison S. Devonshire
Alison S. Devonshire
DODenise M. O’sUllivan
Denise M. O’sUllivan
IHIsobella Honeyborne
Isobella Honeyborne
GJGerwyn Jones
Gerwyn Jones
MKMaria Karczmarczyk
Maria Karczmarczyk
JHJim Huggett
Jim Huggett
Real-time PCR (qPCR) based methods, such as the Xpert MTB/RIF, are increasingly being used to diagnose tuberculosis (TB). While qualitative methods are adequate for diagnosis, the therapeutic monitoring of TB patients requires quantitative methods currently performed using smear microscopy. The potential use of quantitative molecular measurements for therapeutic monitoring has been investigated but findings have been variable and inconclusive. The lack of an adequate reference method and reference materials is a barrier to understanding the source of such disagreement. Digital PCR (dPCR) offers the potential for an accurate method for quantification of specific DNA sequences in reference materials which can be used to evaluate quantitative molecular methods for TB treatment monitoring. To assess a novel approach for the development of quality assurance materials we used dPCR to quantify specific DNA sequences in a range of prototype reference materials and evaluated accuracy between different laboratories and instruments. The materials were then also used to evaluate the quantitative performance of qPCR and Xpert MTB/RIF in eight clinical testing laboratories. dPCR was found to provide results in good agreement with the other methods tested and to be highly reproducible between laboratories without calibration even when using different instruments. When the reference materials were analysed with qPCR and Xpert MTB/RIF by clinical laboratories, all laboratories were able to correctly rank the reference materials according to concentration, however there was a marked difference in the measured magnitude. TB is a disease where the quantification of the pathogen could lead to better patient management and qPCR methods offer the potential to rapidly perform such analysis. However, our findings suggest that when precisely characterised materials are used to evaluate qPCR methods, the measurement result variation is too high to determine whether molecular quantification of Mycobacterium tuberculosis would provide a clinically useful readout. The methods described in this study provide a means by which the technical performance of quantitative molecular methods can be evaluated independently of clinical variability to improve accuracy of measurement results. These will assist in ultimately increasing the likelihood that such approaches could be used to improve patient management of TB.

30 November 2016 in Analytical Chemistry
Verified
Journal Article
Closed access
HYHee-Bong Yoo
Hee-Bong Yoo
SPSang-Ryoul Park
Sang-Ryoul Park
LDLianhua Dong
Lianhua Dong
JWJing Wang
Jing Wang
ZSZhiwei Sui
Zhiwei Sui
PVPeter M. Vallone
Peter M. Vallone

5 November 2015 in Applied Biochemistry and Biotechnology
Verified
Journal Article
Closed access
PDF file
EMErkan Mozioglu
Erkan Mozioglu
OGOzgur Gokmen
Ozgur Gokmen
Candan TamerlerCandan Tamerler
Candan Tamerler
TKTanil Kocagoz
Tanil Kocagoz
MAMuslum Akgoz
Muslum Akgoz

26 January 2017 in Analytical and Bioanalytical Chemistry
Verified
Journal Article
Open access
PDF file
JPJernej Pavšič
Jernej Pavšič
ADAlison Devonshire
Alison Devonshire
ABAndrej Blejec
Andrej Blejec
CFCarole A Foy
Carole A Foy
FHFran Van Heuverswyn
Fran Van Heuverswyn
MMMojca Milavec
Mojca Milavec
Quantitative PCR (qPCR) is an important tool in pathogen detection. However, the use of different qPCR components, calibration materials and DNA extraction methods reduces comparability between laboratories, which can result in false diagnosis and discrepancies in patient care. The wider establishment of a metrological framework for nucleic acid tests could improve the degree of standardisation of pathogen detection and the quantification methods applied in the clinical context. To achieve this, accurate methods need to be developed and implemented as reference measurement procedures, and to facilitate characterisation of suitable certified reference materials. Digital PCR (dPCR) has already been used for pathogen quantification by analysing nucleic acids. Although dPCR has the potential to provide robust and accurate quantification of nucleic acids, further assessment of its actual performance characteristics is needed before it can be implemented in a metrological framework, and to allow adequate estimation of measurement uncertainties. Here, four laboratories demonstrated reproducibility (expanded measurement uncertainties below 15%) of dPCR for quantification of DNA from human cytomegalovirus, with no calibration to a common reference material. Using whole-virus material and extracted DNA, an intermediate precision (coefficients of variation below 25%) between three consecutive experiments was noted. Furthermore, discrepancies in estimated mean DNA copy number concentrations between laboratories were less than twofold, with DNA extraction as the main source of variability. These data demonstrate that dPCR offers a repeatable and reproducible method for quantification of viral DNA, and due to its satisfactory performance should be considered as candidate for reference methods for implementation in a metrological framework.