Xian Liao

Dr. Xian Liao


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2019 in IEEE Geoscience and Remote Sensing Letters
Verified
Journal Article
Closed access
SQShanqiang Qin
Shanqiang Qin
YWYao Wang
Yao Wang
ZXZhengyu Xu
Zhengyu Xu
XLXian Liao
Xian Liao
LLLonghuan Liu
Longhuan Liu
ZFZhihong Fu
Zhihong Fu
Transient electromagnetic (TEM) soundings are being increasingly used in engineering applications of environmental and regional surveys and shallow metal detection. Efficient and real time of the processing of the observed TEM data is the trend for the engineering geophysical prospecting and detection instrument in modern times. This letter presents a fast resistivity imaging method of TEM using artificial neural networks. The input-output mapping relations of neural networks are established based on the TEM response characteristics under different transmitter loop devices. The built network could map the recorded TEM data and quickly obtain the resistivity image. The proposed method offers accuracy and fast computation for resistivity imaging, and only 9.003 s costs for the calculation of 142 measured points' data. Feasibility and technical attractiveness of the proposed method in fast resistivity imaging of TEM mean that it is well suited for instantaneous of survey results to a client. The proposed TEM imaging method can be used in real time so that the recorded TEM data can be calculated without retraining, which avoids time-consuming iteration and inversion computation.

18 January 2023 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
ZXZhengyu Xu
Zhengyu Xu
XLXian Liao
Xian Liao
LLLonghuan Liu
Longhuan Liu
NFNengyi Fu
Nengyi Fu
ZFZhihong Fu
Zhihong Fu
The small-loop transient electromagnetic (TEM) method has great application prospects in shallow surface geophysical exploration. However, the theoretical research on the forward and inversion of this method is obviously lagging behind, which seriously affects the application effect in practical engineering. For the oscillation problem of the small-loop TEM response calculated by using the forward theory of the conventional TEM methods, the dipole integral superposition method was proposed to solve the problem in this paper. The transmitter source is divided into an infinite number of electric dipoles, and the calculation expressions of the electromagnetic field components satisfied by the electric dipoles are deduced, and the forward calculation problem of the layered model of the small-loop TEM method is solved. For the small-loop TEM method inversion problem, the simulated annealing (SA) method was presented for inversion calculation in this paper. First, the influence of the selection of the initial temperature on the inversion result of the SA algorithm was analyzed. Then, we demonstrate the algorithm’s flexibility by choosing different initial models and search ranges and concluded that the different initial models and search ranges don’t affect the inversion results of the SA algorithm. Next, the typical layered models were established and the SA algorithm was used to carry out calculations. The research results show that the SA algorithm is an excellent global optimization algorithm, which can easily jump out of the local minima and converge to the global minima. Finally, we processed the measured data through inversion calculations and compared it with the results of the other three methods to verify the effectiveness and accuracy of the SA algorithm for small-loop TEM data processing. The research content solves the theoretical problem of the small-loop TEM method forward and inversion, promotes the development of the small-loop TEM method technology, and objectively and effectively solves practical engineering application problems.

14 September 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Open access
XLXian Liao
Xian Liao
ZXZhengyu Xu
Zhengyu Xu
WLWei Liu
Wei Liu
XHXuquan Hu
Xuquan Hu
JZJie Zhou
Jie Zhou
ZFZhihong Fu
Zhihong Fu
In transient electromagnetic (TEM) inverter circuits, a damping resistor is typically connected in parallel to the transmitting coil to prevent overshoot during the turn-off period of the pulse current. This configuration results in an exponential decay waveform for the pulse current, which prolongs the turn-off time and increases the nonlinear error. This article analyzes the impact of the parasitic capacitance on the value of the damping resistor and the end-period waveform of the pulse current base on the inverter circuits, and proposes an optimized control method to reduce both the turn-off time and the nonlinear error of the pulse current. The method is validated through the construction of an experimental circuit. According to the experimental data, this optimization method reduces the turn-off time by 23.8% and the nonlinear error by 5.5%. In the unexploded ordnance (UXO) detection experiment, the optimization method’s detection results exhibit higher resolution.

20 September 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
WLWei Liu
Wei Liu
XHXuquan Hu
Xuquan Hu
XLXian Liao
Xian Liao
LLLonghuan Liu
Longhuan Liu
ZFZhihong Fu
Zhihong Fu
This article presents a novel design of a bipolar current-pulsed power supply (BCPPS) for shallow electromagnetic detection. Problems of acquiring current pulses with low oscillation and low energy cost are analyzed in detail and relevant solutions are given. An improved topology based on a constant-voltage clamping circuit is proposed to satisfy the demands of supplying the highly inductive load. The relationship between the main steady-state parameters of the proposed BCPPS is provided and the shape of current pulses can be adjusted flexibly by changing the duty cycles of the switching signals in the topology. A feedforward control strategy to realize constant-current transmitting is proposed and the digital controller is designed. Compared with different existing current-pulsed sources, the topology in this article is characterized by high repeat frequency, low energy cost, and low switching interference. A laboratory prototype with a maximum peak current of 50 A and repeat frequency of 500 Hz is built to verify the effectiveness of the proposed topology.

12 May 2022 in Lithosphere
Verified
Journal Article
Open access
PDF file
XLXinglin Lu
Xinglin Lu
XHXuquan Hu
Xuquan Hu
ZXZhengyu Xu
Zhengyu Xu
XLXian Liao
Xian Liao
LLLonghuan Liu
Longhuan Liu
ZFZhihong Fu
Zhihong Fu
The water-rich giant karst cave is the risk source of tunnel construction in the karst area. To reduce the risk of tunnel construction, it is necessary to accurately explore the spatial distribution range of the karst cave in the direction of advance and both sides of the tunnel. Reflection seismic and transient electromagnetic (TEM) are the primary geophysical tools for tunnel advanced prediction; they have strengths and weaknesses. The tunnel seismic can only describe the boundary interface between cave bodies and surrounding rock in the direction of advance. Although the TEM method can detect the spatial distribution range of cave bodies, the inversion results depend on the initial resistivity model. The single method is insufficient to describe the spatial distribution of cave bodies. To overcome the shortcoming of a single method, we developed tunnel seismic and TEM joint detection of karst cavern and established a complete data processing flow. The tunnel seismic migration profiles can describe the interface between the karst cave and surrounding rock in the direction of advance. We put forward a reasonable initial model: (1) the layer’s thicknesses are determined by the impedance interface from the tunnel migration data; (2) the initial resistivity values are determined from the pilot hole and prior geological data. Comparison of the inversion results of different initial models of tunnel face horizontal line data proves that the proposed initial model method can reduce multisolution, save calculation time, and improve inversion accuracy. The multidirectional TEM inversion profiles can describe the spatial distribution of the giant cave. Combined with the results of tunnel seismic and TEM, the interpretation errors can be reduced and the extension of the karst cave can be delineated. Later excavation results also verify the accuracy of the prediction results.

29 August 2019 in Sensors
Verified
Journal Article
Open access
PDF file
YWYao Wang
Yao Wang
NFNengyi Fu
Nengyi Fu
ZFZhihong Fu
Zhihong Fu
XLXinglin Lu
Xinglin Lu
XLXian Liao
Xian Liao
SQShanqiang Qin
Shanqiang Qin
The tunnel seismic method allows for the detection of the geology in front of a tunnel face for the safety of tunnel construction. Conventional geophones have problems such as a narrow spectral width, low sensitivity, and poor coupling with the tunnel wall. To tackle issues above, we propose a semi-automatic coupling geophone equipped with a piezoelectric sensor with a spectral range of 10–5000 Hz and a sensitivity of 2.8 V/g. After the geophone was manually pushed into the borehole, it automatically coupled with the tunnel wall under the pressure of the springs within the device. A comparative experiment showed that the data spectrum acquired by the semi-automatic coupling geophone was much higher than that of the conventional geophone equipped with the same piezoelectric sensor. The seismic data were processed in combination with forward modeling. The imaging results also show that the data acquired by the semi-automatic coupling geophone were more in line with the actual geological conditions. In addition, the semi-automatic coupling geophone’s installation requires a lower amount of time and cost. In summary, the semi-automatic coupling geophone is able to efficiently acquire seismic data with high fidelity, which can provide a reference for tunnel construction safety.