This paper presents a novel load shedding scheme with consideration of the active power ramping capability of Distributed Energy Resources (DERs) to address the challenges due to low inertia and diverse types of DERs in microgrids. In the paper, it is demonstrated that due to the small inertia in microgrids, even with sufficient reserve power, the frequency could rapidly drop to a low level and trigger the DERs’ under frequency protection (thus the total system collapse), if the reserve active power is not ramped up at a sufficient rate. The proposed load shedding scheme addresses this challenge by considering not only the DERs’ reserve, but also their speed in injecting active power to the system to determine the amount of load should be shed, so that critical frequency thresholds are not violated. The proposed load shedding scheme is tested using a realistic real time hardware-in-the-loop arrangement. The results show that the proposed scheme can correctly detect the cases when the DERs’ responses are too slow and trigger the required load shedding actions, thus effectively containing the frequency above the critical threshold.
This paper presents an improved inverse-time over-current protection method based on the compound fault acceleration factor and the beetle antennae search (BAS) optimization method for a microgrid. The proposed method can not only significantly increase the operation speed of the inverse-time over-current protection but also improve the protection coordination by considering the possible influential factors in terms of microgrid operation modes, distributed generation (DG) integration status, fault types, and positions, which are marked as the most challenging problems for over-current protection of a microgrid. In this paper, a new Time Dial Setting (TDS) of inverse-time protection is developed by applying a compound fault acceleration factor, which can notably accelerate the speed of protection by using low-voltage and short-circuit impedance during the fault. In order to improve the protection coordination, the BAS algorithm is then used to optimize the protection parameters of the pick-up current, TDS, and the inverse time curve shape coefficient. Finally, case studies and various evaluations based on DIgSILENT/Power Factory are carried out to illustrate the effectiveness of the proposed method.
22 July 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The modular multilevel converter (MMC) open-circuit fault diagnosis under full power condition has become a challenging problem. Especially when MMC operates under low power condition, there are significant fluctuations in capacitor voltage and the existing fault diagnosis strategies face difficulties in selecting appropriate thresholds. The paper proposes a multiple open-circuit fault diagnosis strategy for MMC using Feature Reconstruction-Recurrent Neural Network (FR-RNN). In this method, the dominant characteristics of the theoretical and actual capacitor current of the submodules (SMs) are presented as the preferred feature set. The auxiliary mathematical feature based on capacitor current was screened using Maximal Information Coefficient (MIC), then the selected auxiliary mathematical feature and preferred feature set were inputted into the RNN for FR to realize fault diagnosis based on optimal feature set. The proposed strategy can directly achieve accurate fault localization and fault type judgment of SM faults without additional detection steps and diagnostic delay. Additionally, the determined optimal feature set greatly simplifies the network computation, thus avoiding deviation caused by multi-dimensional and redundant features on the diagnosis outputs. Simulation and experimental studies confirm the effectiveness of the strategy.
15 January 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The modular multilevel converter (MMC) is an attractive option for high-voltage and high-power applications. Fault localization is one of the most challenging tasks for the MMC consisting of a large number of power electronic switches. Existing literatures have not provided a complete fault localization strategy for MMC submodule (SM) capacitor voltage tangency under different voltage balancing strategies as well as modulation methods. This article proposes a fault localization strategy for the MMC under open-circuit fault, which is suitable for the MMC controlled by both pulse wide modulation (PWM) and nearest level modulation (NLM). This article also considers the error during computing process. based on fault characteristic which eliminate error between adjacent calculation steps, the faulty SM can be effectively located by the proposed strategy without effect of computing error. The proposed strategy is implemented by simulation with MATLAB/Simulink and by an experiment with a downscale MMC prototype. The experimental results confirm the effectiveness of the proposed strategy.
24 December 2020 in IET Generation, Transmission & Distribution
The optimised droop control method is proposed to achieve the state‐of‐charge (SoC) balance among parallel‐connected distributed energy storage units in islanded DC microgrid, which considers the difference of line impedance, initial state‐of‐charge values and capacities among distributed energy storage units. Since the droop control is the basic control strategy for load sharing in DC microgrid applications, however, the load sharing accuracy is degraded under conventional droop control method due to the unmatched line impedance in reality. Meanwhile, the initial state‐of‐charge values and capacities of each distributed energy storage unit are usually different. Hence, the state of charge for distributed energy storage units cannot be balanced. In order to prolong the lifetime of the distributed energy storage units and avoid the overuse of a certain distributed energy storage unit, the optimised droop control strategy based on sample and holder is designed, by modifying the droop coefficient adaptively, the accurate load sharing and balanced state of charge among distributed energy storage units are both obtained. Finally, the performance of the proposed control scheme is accessed through a series cases on technologies real‐time digital simulator (RTDS) and its effectiveness is verified.
With the rapid development of modern power systems, the structure and operation of distribution networks are becoming increasingly complex, demanding higher levels of intelligence and digitization. Digital twin, as a virtual cutting-edge technique, can effectively reflect the operational status of distribution networks, offering new possibilities for real-time monitoring, optimization and other functions for distribution networks. Building efficient and accurate models is the foundation of enabling a digital twin of distribution networks. This paper proposes a digital twin operating system for distribution networks with renewable energy based on robust state estimation and deep learning-based renewable energy prediction. Furthermore, the identification and correction of possible bad or missing data based on deep learning are also included to purify the input data for the digital twin system. A digital twin test platform is also proposed in the paper. A case study and evaluations based on a real-time digital simulator are carried out to verify the accuracy and real-time performance of the established digital twin system. In general, the proposed method can provide the basis and foundation for distribution network management and operation, as well as intelligent power system operation.